SAGE Facility MUSTANG metrics Web Service Documentation

amplifier_saturation Amplifier saturation detected

Summary

This metric counts the times this data quality flag is set from 0 (default) to 1 in the fixed section of the miniSEED header. A flag value of 1 was intended to indicate that the preamplifier is being overdriven, but the exact meaning is datalogger-specific. Not all dataloggers set this flag.

PH5-format data does not include miniSEED flag information; this metric will always return a value of 0 for data in the IRIS PH5 archive.

Uses

This metric can be searched to determine when a datalogger or station was known to have had this particular problem so that the station can be serviced or the affected data omitted from a user’s research.

If using this metric with the rrds service, be aware that a value of 0 (zero) can either mean that

  • the datalogger detected 0 instances of this condition, or
  • the datalogger does not set this flag, so it is unknown whether or not this condition occurred.

Unless all channels in an rrds request are known to set this flag, requesting only data with a count of 0 will not necessarily omit all data for which this condition occurred.

Data Analyzed

Traces – one N.S.L.C (Network.Station.Location.Channel) per measurement
Window – 24 hours starting at 00:00:00 UTC
Data SourceIRIS miniSEED archive

SEED Channel Types – ?H?, ?L?, ?N?, ?G?, ?P?, VM? | High Gain, Low Gain, Accelerometer, Gravimeter, Geophone, Mass Channels

Algorithm

  • Request 24 hours of data for a single N.S.L.C.
  • Count and report the number times this binary flag is set to 1.

Metric Values Returned

value – number of times this flag is set to 1 that day
target – the trace analyzed, labeled as N.S.L.C.Q (Network.Station.Location.Channel.Quality)
start – beginning of the data day requested (00:00:00 UTC)
end – end of the data day requested (truncated as 23:59:59 UTC)
lddate – date/time the measurement was made and loaded into the MUSTANG database (UTC)

Notes

Not all dataloggers set this flag. For those that do not, a value of 0 does not necessarily mean that an amplifier is behaving linearly.

Contact

Updated