#Network | Station | Location | Channel | Latitude | Longitude | Elevation | Depth | Azimuth | Dip | SensorDescription | Scale | ScaleFreq | ScaleUnits | SampleRate | StartTime | EndTime

#DATACENTER=IRISDMC,https://www.earthscope.org/data/
XO|EP14||ACE|59.3257|-155.9036|56.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-06-06T00:00:00|2019-12-31T23:59:59
XO|EP14||HHE|59.3257|-155.9036|56.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-06-06T00:00:00|2019-12-31T23:59:59
XO|EP14||HHN|59.3257|-155.9036|56.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-06-06T00:00:00|2019-12-31T23:59:59
XO|EP14||HHZ|59.3257|-155.9036|56.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-06-06T00:00:00|2019-12-31T23:59:59
XO|EP14||LCE|59.3257|-155.9036|56.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-06-06T00:00:00|2019-12-31T23:59:59
XO|EP14||LCQ|59.3257|-155.9036|56.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-06-06T00:00:00|2019-12-31T23:59:59
XO|EP14||LHE|59.3257|-155.9036|56.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-06-06T00:00:00|2019-12-31T23:59:59
XO|EP14||LHN|59.3257|-155.9036|56.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-06-06T00:00:00|2019-12-31T23:59:59
XO|EP14||LHZ|59.3257|-155.9036|56.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-06-06T00:00:00|2019-12-31T23:59:59
XO|EP14||LOG|59.3257|-155.9036|56.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-06-06T00:00:00|2019-12-31T23:59:59
XO|EP14||OCF|59.3257|-155.9036|56.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-06-06T00:00:00|2019-12-31T23:59:59
XO|EP14||VCO|59.3257|-155.9036|56.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-06-06T00:00:00|2019-12-31T23:59:59
XO|EP14||VEA|59.3257|-155.9036|56.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-06-06T00:00:00|2019-12-31T23:59:59
XO|EP14||VEC|59.3257|-155.9036|56.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-06-06T00:00:00|2019-12-31T23:59:59
XO|EP14||VEP|59.3257|-155.9036|56.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-06-06T00:00:00|2019-12-31T23:59:59
XO|EP14||VKI|59.3257|-155.9036|56.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-06-06T00:00:00|2019-12-31T23:59:59
XO|EP14||VM1|59.3257|-155.9036|56.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-06-06T00:00:00|2019-12-31T23:59:59
XO|EP14||VM2|59.3257|-155.9036|56.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-06-06T00:00:00|2019-12-31T23:59:59
XO|EP14||VM3|59.3257|-155.9036|56.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-06-06T00:00:00|2019-12-31T23:59:59
XO|EP14||VPB|59.3257|-155.9036|56.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-06-06T00:00:00|2019-12-31T23:59:59
XO|EP15||ACE|58.9664|-155.0867|249.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-06-10T12:00:00|2019-12-31T23:59:59
XO|EP15||HHE|58.9664|-155.0867|249.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-06-10T12:00:00|2019-12-31T23:59:59
XO|EP15||HHN|58.9664|-155.0867|249.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-06-10T12:00:00|2019-12-31T23:59:59
XO|EP15||HHZ|58.9664|-155.0867|249.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-06-10T12:00:00|2019-12-31T23:59:59
XO|EP15||LCE|58.9664|-155.0867|249.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-06-10T12:00:00|2019-12-31T23:59:59
XO|EP15||LCQ|58.9664|-155.0867|249.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-06-10T12:00:00|2019-12-31T23:59:59
XO|EP15||LHE|58.9664|-155.0867|249.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-06-10T12:00:00|2019-12-31T23:59:59
XO|EP15||LHN|58.9664|-155.0867|249.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-06-10T12:00:00|2019-12-31T23:59:59
XO|EP15||LHZ|58.9664|-155.0867|249.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-06-10T12:00:00|2019-12-31T23:59:59
XO|EP15||LOG|58.9664|-155.0867|249.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-06-10T12:00:00|2019-12-31T23:59:59
XO|EP15||OCF|58.9664|-155.0867|249.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-06-10T12:00:00|2019-12-31T23:59:59
XO|EP15||VCO|58.9664|-155.0867|249.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-06-10T12:00:00|2019-12-31T23:59:59
XO|EP15||VEA|58.9664|-155.0867|249.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-06-10T12:00:00|2019-12-31T23:59:59
XO|EP15||VEC|58.9664|-155.0867|249.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-06-10T12:00:00|2019-12-31T23:59:59
XO|EP15||VEP|58.9664|-155.0867|249.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-06-10T12:00:00|2019-12-31T23:59:59
XO|EP15||VKI|58.9664|-155.0867|249.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-06-10T12:00:00|2019-12-31T23:59:59
XO|EP15||VM1|58.9664|-155.0867|249.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-06-10T12:00:00|2019-12-31T23:59:59
XO|EP15||VM2|58.9664|-155.0867|249.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-06-10T12:00:00|2019-12-31T23:59:59
XO|EP15||VM3|58.9664|-155.0867|249.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-06-10T12:00:00|2019-12-31T23:59:59
XO|EP15||VPB|58.9664|-155.0867|249.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-06-10T12:00:00|2019-12-31T23:59:59
XO|EP16||ACE|59.1126|-156.8567|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-06-05T12:00:00|2019-12-31T23:59:59
XO|EP16||HHE|59.1126|-156.8567|43.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-06-05T12:00:00|2019-12-31T23:59:59
XO|EP16||HHN|59.1126|-156.8567|43.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-06-05T12:00:00|2019-12-31T23:59:59
XO|EP16||HHZ|59.1126|-156.8567|43.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-06-05T12:00:00|2019-12-31T23:59:59
XO|EP16||LCE|59.1126|-156.8567|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-06-05T12:00:00|2019-12-31T23:59:59
XO|EP16||LCQ|59.1126|-156.8567|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-06-05T12:00:00|2019-12-31T23:59:59
XO|EP16||LHE|59.1126|-156.8567|43.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-06-05T12:00:00|2019-12-31T23:59:59
XO|EP16||LHN|59.1126|-156.8567|43.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-06-05T12:00:00|2019-12-31T23:59:59
XO|EP16||LHZ|59.1126|-156.8567|43.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-06-05T12:00:00|2019-12-31T23:59:59
XO|EP16||LOG|59.1126|-156.8567|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-06-05T12:00:00|2019-12-31T23:59:59
XO|EP16||OCF|59.1126|-156.8567|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-06-05T12:00:00|2019-12-31T23:59:59
XO|EP16||VCO|59.1126|-156.8567|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-06-05T12:00:00|2019-12-31T23:59:59
XO|EP16||VEA|59.1126|-156.8567|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-06-05T12:00:00|2019-12-31T23:59:59
XO|EP16||VEC|59.1126|-156.8567|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-06-05T12:00:00|2019-12-31T23:59:59
XO|EP16||VEP|59.1126|-156.8567|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-06-05T12:00:00|2019-12-31T23:59:59
XO|EP16||VKI|59.1126|-156.8567|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-06-05T12:00:00|2019-12-31T23:59:59
XO|EP16||VM1|59.1126|-156.8567|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-06-05T12:00:00|2019-12-31T23:59:59
XO|EP16||VM2|59.1126|-156.8567|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-06-05T12:00:00|2019-12-31T23:59:59
XO|EP16||VM3|59.1126|-156.8567|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-06-05T12:00:00|2019-12-31T23:59:59
XO|EP16||VPB|59.1126|-156.8567|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-06-05T12:00:00|2019-12-31T23:59:59
XO|EP21||ACE|58.212|-157.3769|46.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP21||HHE|58.212|-157.3769|46.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP21||HHN|58.212|-157.3769|46.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP21||HHZ|58.212|-157.3769|46.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP21||LCE|58.212|-157.3769|46.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP21||LCQ|58.212|-157.3769|46.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP21||LHE|58.212|-157.3769|46.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP21||LHN|58.212|-157.3769|46.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP21||LHZ|58.212|-157.3769|46.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP21||LOG|58.212|-157.3769|46.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP21||OCF|58.212|-157.3769|46.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP21||VCO|58.212|-157.3769|46.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP21||VEA|58.212|-157.3769|46.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP21||VEC|58.212|-157.3769|46.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP21||VEP|58.212|-157.3769|46.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP21||VKI|58.212|-157.3769|46.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP21||VM1|58.212|-157.3769|46.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP21||VM2|58.212|-157.3769|46.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP21||VM3|58.212|-157.3769|46.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP21||VPB|58.212|-157.3769|46.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP22||ACE|57.9007|-155.7865|63.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP22||HHE|57.9007|-155.7865|63.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP22||HHN|57.9007|-155.7865|63.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP22||HHZ|57.9007|-155.7865|63.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP22||LCE|57.9007|-155.7865|63.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP22||LCQ|57.9007|-155.7865|63.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP22||LHE|57.9007|-155.7865|63.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP22||LHN|57.9007|-155.7865|63.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP22||LHZ|57.9007|-155.7865|63.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP22||LOG|57.9007|-155.7865|63.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP22||OCF|57.9007|-155.7865|63.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP22||VCO|57.9007|-155.7865|63.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP22||VEA|57.9007|-155.7865|63.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP22||VEC|57.9007|-155.7865|63.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP22||VEP|57.9007|-155.7865|63.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP22||VKI|57.9007|-155.7865|63.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP22||VM1|57.9007|-155.7865|63.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP22||VM2|57.9007|-155.7865|63.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP22||VM3|57.9007|-155.7865|63.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP22||VPB|57.9007|-155.7865|63.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-06-04T12:00:00|2019-12-31T23:59:59
XO|EP23||ACE|56.9071|-157.0201|39.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-06-02T18:00:00|2019-12-31T23:59:59
XO|EP23||HHE|56.9071|-157.0201|39.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-06-02T18:00:00|2019-12-31T23:59:59
XO|EP23||HHN|56.9071|-157.0201|39.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-06-02T18:00:00|2019-12-31T23:59:59
XO|EP23||HHZ|56.9071|-157.0201|39.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-06-02T18:00:00|2019-12-31T23:59:59
XO|EP23||LCE|56.9071|-157.0201|39.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-06-02T18:00:00|2019-12-31T23:59:59
XO|EP23||LCQ|56.9071|-157.0201|39.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-06-02T18:00:00|2019-12-31T23:59:59
XO|EP23||LHE|56.9071|-157.0201|39.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-06-02T18:00:00|2019-12-31T23:59:59
XO|EP23||LHN|56.9071|-157.0201|39.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-06-02T18:00:00|2019-12-31T23:59:59
XO|EP23||LHZ|56.9071|-157.0201|39.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-06-02T18:00:00|2019-12-31T23:59:59
XO|EP23||LOG|56.9071|-157.0201|39.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-06-02T18:00:00|2019-12-31T23:59:59
XO|EP23||OCF|56.9071|-157.0201|39.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-06-02T18:00:00|2019-12-31T23:59:59
XO|EP23||VCO|56.9071|-157.0201|39.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-06-02T18:00:00|2019-12-31T23:59:59
XO|EP23||VEA|56.9071|-157.0201|39.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-06-02T18:00:00|2019-12-31T23:59:59
XO|EP23||VEC|56.9071|-157.0201|39.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-06-02T18:00:00|2019-12-31T23:59:59
XO|EP23||VEP|56.9071|-157.0201|39.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-06-02T18:00:00|2019-12-31T23:59:59
XO|EP23||VKI|56.9071|-157.0201|39.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-06-02T18:00:00|2019-12-31T23:59:59
XO|EP23||VM1|56.9071|-157.0201|39.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-06-02T18:00:00|2019-12-31T23:59:59
XO|EP23||VM2|56.9071|-157.0201|39.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-06-02T18:00:00|2019-12-31T23:59:59
XO|EP23||VM3|56.9071|-157.0201|39.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-06-02T18:00:00|2019-12-31T23:59:59
XO|EP23||VPB|56.9071|-157.0201|39.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-06-02T18:00:00|2019-12-31T23:59:59
XO|ET17||ACE|58.6097|-156.265|51.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET17||HHE|58.6097|-156.265|51.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET17||HHN|58.6097|-156.265|51.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET17||HHZ|58.6097|-156.265|51.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET17||LCE|58.6097|-156.265|51.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET17||LCQ|58.6097|-156.265|51.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET17||LHE|58.6097|-156.265|51.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET17||LHN|58.6097|-156.265|51.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET17||LHZ|58.6097|-156.265|51.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET17||LOG|58.6097|-156.265|51.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET17||OCF|58.6097|-156.265|51.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET17||VCO|58.6097|-156.265|51.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET17||VEA|58.6097|-156.265|51.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET17||VEC|58.6097|-156.265|51.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET17||VEP|58.6097|-156.265|51.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET17||VKI|58.6097|-156.265|51.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET17||VM1|58.6097|-156.265|51.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET17||VM2|58.6097|-156.265|51.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET17||VM3|58.6097|-156.265|51.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET17||VPB|58.6097|-156.265|51.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET18||ACE|58.5458|-155.788|60.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-06-10T00:00:00|2019-12-31T23:59:59
XO|ET18||HH1|58.5458|-155.788|60.0|0.0|43.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-06-10T00:00:00|2019-12-31T23:59:59
XO|ET18||HH2|58.5458|-155.788|60.0|0.0|133.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-06-10T00:00:00|2019-12-31T23:59:59
XO|ET18||HHE|58.5458|-155.788|60.0|0.0|133.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-06-10T00:00:00|2019-12-31T23:59:59
XO|ET18||HHN|58.5458|-155.788|60.0|0.0|43.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-06-10T00:00:00|2019-12-31T23:59:59
XO|ET18||HHZ|58.5458|-155.788|60.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-06-10T00:00:00|2019-12-31T23:59:59
XO|ET18||LCE|58.5458|-155.788|60.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-06-10T00:00:00|2019-12-31T23:59:59
XO|ET18||LCQ|58.5458|-155.788|60.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-06-10T00:00:00|2019-12-31T23:59:59
XO|ET18||LH1|58.5458|-155.788|60.0|0.0|43.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-06-10T00:00:00|2019-12-31T23:59:59
XO|ET18||LH2|58.5458|-155.788|60.0|0.0|133.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-06-10T00:00:00|2019-12-31T23:59:59
XO|ET18||LHE|58.5458|-155.788|60.0|0.0|133.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-06-10T00:00:00|2019-12-31T23:59:59
XO|ET18||LHN|58.5458|-155.788|60.0|0.0|43.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-06-10T00:00:00|2019-12-31T23:59:59
XO|ET18||LHZ|58.5458|-155.788|60.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-06-10T00:00:00|2019-12-31T23:59:59
XO|ET18||LOG|58.5458|-155.788|60.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-06-10T00:00:00|2019-12-31T23:59:59
XO|ET18||OCF|58.5458|-155.788|60.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-06-10T00:00:00|2019-12-31T23:59:59
XO|ET18||VCO|58.5458|-155.788|60.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-06-10T00:00:00|2019-12-31T23:59:59
XO|ET18||VEA|58.5458|-155.788|60.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-06-10T00:00:00|2019-12-31T23:59:59
XO|ET18||VEC|58.5458|-155.788|60.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-06-10T00:00:00|2019-12-31T23:59:59
XO|ET18||VEP|58.5458|-155.788|60.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-06-10T00:00:00|2019-12-31T23:59:59
XO|ET18||VKI|58.5458|-155.788|60.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-06-10T00:00:00|2019-12-31T23:59:59
XO|ET18||VM1|58.5458|-155.788|60.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-06-10T00:00:00|2019-12-31T23:59:59
XO|ET18||VM2|58.5458|-155.788|60.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-06-10T00:00:00|2019-12-31T23:59:59
XO|ET18||VM3|58.5458|-155.788|60.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-06-10T00:00:00|2019-12-31T23:59:59
XO|ET18||VPB|58.5458|-155.788|60.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-06-10T00:00:00|2019-12-31T23:59:59
XO|ET19||ACE|58.3686|-155.4394|322.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-06-09T12:00:00|2019-12-31T23:59:59
XO|ET19||HHE|58.3686|-155.4394|322.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-06-09T12:00:00|2019-12-31T23:59:59
XO|ET19||HHN|58.3686|-155.4394|322.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-06-09T12:00:00|2019-12-31T23:59:59
XO|ET19||HHZ|58.3686|-155.4394|322.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-06-09T12:00:00|2019-12-31T23:59:59
XO|ET19||LCE|58.3686|-155.4394|322.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-06-09T12:00:00|2019-12-31T23:59:59
XO|ET19||LCQ|58.3686|-155.4394|322.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-06-09T12:00:00|2019-12-31T23:59:59
XO|ET19||LHE|58.3686|-155.4394|322.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-06-09T12:00:00|2019-12-31T23:59:59
XO|ET19||LHN|58.3686|-155.4394|322.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-06-09T12:00:00|2019-12-31T23:59:59
XO|ET19||LHZ|58.3686|-155.4394|322.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-06-09T12:00:00|2019-12-31T23:59:59
XO|ET19||LOG|58.3686|-155.4394|322.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-06-09T12:00:00|2019-12-31T23:59:59
XO|ET19||OCF|58.3686|-155.4394|322.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-06-09T12:00:00|2019-12-31T23:59:59
XO|ET19||VCO|58.3686|-155.4394|322.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-06-09T12:00:00|2019-12-31T23:59:59
XO|ET19||VEA|58.3686|-155.4394|322.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-06-09T12:00:00|2019-12-31T23:59:59
XO|ET19||VEC|58.3686|-155.4394|322.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-06-09T12:00:00|2019-12-31T23:59:59
XO|ET19||VEP|58.3686|-155.4394|322.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-06-09T12:00:00|2019-12-31T23:59:59
XO|ET19||VKI|58.3686|-155.4394|322.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-06-09T12:00:00|2019-12-31T23:59:59
XO|ET19||VM1|58.3686|-155.4394|322.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-06-09T12:00:00|2019-12-31T23:59:59
XO|ET19||VM2|58.3686|-155.4394|322.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-06-09T12:00:00|2019-12-31T23:59:59
XO|ET19||VM3|58.3686|-155.4394|322.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-06-09T12:00:00|2019-12-31T23:59:59
XO|ET19||VPB|58.3686|-155.4394|322.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-06-09T12:00:00|2019-12-31T23:59:59
XO|ET20||ACE|58.1304|-154.9716|965.5|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET20||HHE|58.1304|-154.9716|965.5|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET20||HHN|58.1304|-154.9716|965.5|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET20||HHZ|58.1304|-154.9716|965.5|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET20||LCE|58.1304|-154.9716|965.5|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET20||LCQ|58.1304|-154.9716|965.5|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET20||LHE|58.1304|-154.9716|965.5|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET20||LHN|58.1304|-154.9716|965.5|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET20||LHZ|58.1304|-154.9716|965.5|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET20||LOG|58.1304|-154.9716|965.5|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET20||OCF|58.1304|-154.9716|965.5|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET20||VCO|58.1304|-154.9716|965.5|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET20||VEA|58.1304|-154.9716|965.5|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET20||VEC|58.1304|-154.9716|965.5|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET20||VEP|58.1304|-154.9716|965.5|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET20||VKI|58.1304|-154.9716|965.5|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET20||VM1|58.1304|-154.9716|965.5|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET20||VM2|58.1304|-154.9716|965.5|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET20||VM3|58.1304|-154.9716|965.5|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|ET20||VPB|58.1304|-154.9716|965.5|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-06-08T00:00:00|2019-12-31T23:59:59
XO|KD00||ACE|57.4413|-152.4484|98.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-09-07T18:00:00|2019-12-31T23:59:59
XO|KD00||EHE|57.4413|-152.4484|98.0|0.0|90.0|0.0|Mark Products L22/Quanterra 330 Linear Phase Compo|3.64462E7|5.0|m/s|100.0|2018-09-07T18:00:00|2019-12-31T23:59:59
XO|KD00||EHN|57.4413|-152.4484|98.0|0.0|0.0|0.0|Mark Products L22/Quanterra 330 Linear Phase Compo|3.64462E7|5.0|m/s|100.0|2018-09-07T18:00:00|2019-12-31T23:59:59
XO|KD00||EHZ|57.4413|-152.4484|98.0|0.0|0.0|90.0|Mark Products L22/Quanterra 330 Linear Phase Compo|3.64462E7|5.0|m/s|100.0|2018-09-07T18:00:00|2019-12-31T23:59:59
XO|KD00||HHE|57.4413|-152.4484|98.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2019-05-24T20:00:00|2019-12-31T23:59:59
XO|KD00||HHN|57.4413|-152.4484|98.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2019-05-24T20:00:00|2019-12-31T23:59:59
XO|KD00||HHZ|57.4413|-152.4484|98.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2019-05-24T20:00:00|2019-12-31T23:59:59
XO|KD00||LCE|57.4413|-152.4484|98.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-09-07T18:00:00|2019-12-31T23:59:59
XO|KD00||LCQ|57.4413|-152.4484|98.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-09-07T18:00:00|2019-12-31T23:59:59
XO|KD00||LHE|57.4413|-152.4484|98.0|0.0|90.0|0.0|Mark Products L22/Quanterra 330 Linear Phase Compo|369060.0|0.2|m/s|1.0|2018-09-07T18:00:00|2019-05-24T20:00:00
XO|KD00||LHE|57.4413|-152.4484|98.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2019-05-24T20:00:00|2019-12-31T23:59:59
XO|KD00||LHN|57.4413|-152.4484|98.0|0.0|0.0|0.0|Mark Products L22/Quanterra 330 Linear Phase Compo|369060.0|0.2|m/s|1.0|2018-09-07T18:00:00|2019-05-24T20:00:00
XO|KD00||LHN|57.4413|-152.4484|98.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2019-05-24T20:00:00|2019-12-31T23:59:59
XO|KD00||LHZ|57.4413|-152.4484|98.0|0.0|0.0|90.0|Mark Products L22/Quanterra 330 Linear Phase Compo|369060.0|0.2|m/s|1.0|2018-09-07T18:00:00|2019-05-24T20:00:00
XO|KD00||LHZ|57.4413|-152.4484|98.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2019-05-24T20:00:00|2019-12-31T23:59:59
XO|KD00||LOG|57.4413|-152.4484|98.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-09-07T18:00:00|2019-12-31T23:59:59
XO|KD00||OCF|57.4413|-152.4484|98.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-09-07T18:00:00|2019-12-31T23:59:59
XO|KD00||VCO|57.4413|-152.4484|98.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-09-07T18:00:00|2019-12-31T23:59:59
XO|KD00||VEA|57.4413|-152.4484|98.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-09-07T18:00:00|2019-12-31T23:59:59
XO|KD00||VEC|57.4413|-152.4484|98.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-09-07T18:00:00|2019-12-31T23:59:59
XO|KD00||VEP|57.4413|-152.4484|98.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-09-07T18:00:00|2019-12-31T23:59:59
XO|KD00||VKI|57.4413|-152.4484|98.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-09-07T18:00:00|2019-12-31T23:59:59
XO|KD00||VM1|57.4413|-152.4484|98.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-09-07T18:00:00|2019-12-31T23:59:59
XO|KD00||VM2|57.4413|-152.4484|98.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-09-07T18:00:00|2019-12-31T23:59:59
XO|KD00||VM3|57.4413|-152.4484|98.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-09-07T18:00:00|2019-12-31T23:59:59
XO|KD00||VPB|57.4413|-152.4484|98.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-09-07T18:00:00|2019-12-31T23:59:59
XO|KD01||ACE|57.6401|-152.4375|79.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-23T00:00:00|2019-12-31T23:59:59
XO|KD01||HHE|57.6401|-152.4375|79.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-23T00:00:00|2019-12-31T23:59:59
XO|KD01||HHN|57.6401|-152.4375|79.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-23T00:00:00|2019-12-31T23:59:59
XO|KD01||HHZ|57.6401|-152.4375|79.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-23T00:00:00|2019-12-31T23:59:59
XO|KD01||LCE|57.6401|-152.4375|79.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-05-23T00:00:00|2019-12-31T23:59:59
XO|KD01||LCQ|57.6401|-152.4375|79.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-05-23T00:00:00|2019-12-31T23:59:59
XO|KD01||LHE|57.6401|-152.4375|79.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-23T00:00:00|2019-12-31T23:59:59
XO|KD01||LHN|57.6401|-152.4375|79.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-23T00:00:00|2019-12-31T23:59:59
XO|KD01||LHZ|57.6401|-152.4375|79.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-23T00:00:00|2019-12-31T23:59:59
XO|KD01||LOG|57.6401|-152.4375|79.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-23T00:00:00|2019-12-31T23:59:59
XO|KD01||OCF|57.6401|-152.4375|79.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-23T00:00:00|2019-12-31T23:59:59
XO|KD01||VCO|57.6401|-152.4375|79.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-23T00:00:00|2019-12-31T23:59:59
XO|KD01||VEA|57.6401|-152.4375|79.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-23T00:00:00|2019-12-31T23:59:59
XO|KD01||VEC|57.6401|-152.4375|79.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-23T00:00:00|2019-12-31T23:59:59
XO|KD01||VEP|57.6401|-152.4375|79.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-23T00:00:00|2019-12-31T23:59:59
XO|KD01||VKI|57.6401|-152.4375|79.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-05-23T00:00:00|2019-12-31T23:59:59
XO|KD01||VM1|57.6401|-152.4375|79.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-23T00:00:00|2019-12-31T23:59:59
XO|KD01||VM2|57.6401|-152.4375|79.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-23T00:00:00|2019-12-31T23:59:59
XO|KD01||VM3|57.6401|-152.4375|79.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-23T00:00:00|2019-12-31T23:59:59
XO|KD01||VPB|57.6401|-152.4375|79.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-05-23T00:00:00|2019-12-31T23:59:59
XO|KD02||ACE|57.8618|-152.6575|57.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-18T00:00:00|2019-12-31T23:59:59
XO|KD02||HHE|57.8618|-152.6575|57.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-18T00:00:00|2019-12-31T23:59:59
XO|KD02||HHN|57.8618|-152.6575|57.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-18T00:00:00|2019-12-31T23:59:59
XO|KD02||HHZ|57.8618|-152.6575|57.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-18T00:00:00|2019-12-31T23:59:59
XO|KD02||LCE|57.8618|-152.6575|57.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-05-18T00:00:00|2019-12-31T23:59:59
XO|KD02||LCQ|57.8618|-152.6575|57.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-05-18T00:00:00|2019-12-31T23:59:59
XO|KD02||LHE|57.8618|-152.6575|57.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-18T00:00:00|2019-12-31T23:59:59
XO|KD02||LHN|57.8618|-152.6575|57.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-18T00:00:00|2019-12-31T23:59:59
XO|KD02||LHZ|57.8618|-152.6575|57.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-18T00:00:00|2019-12-31T23:59:59
XO|KD02||LOG|57.8618|-152.6575|57.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-18T00:00:00|2019-12-31T23:59:59
XO|KD02||OCF|57.8618|-152.6575|57.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-18T00:00:00|2019-12-31T23:59:59
XO|KD02||VCO|57.8618|-152.6575|57.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-18T00:00:00|2019-12-31T23:59:59
XO|KD02||VEA|57.8618|-152.6575|57.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-18T00:00:00|2019-12-31T23:59:59
XO|KD02||VEC|57.8618|-152.6575|57.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-18T00:00:00|2019-12-31T23:59:59
XO|KD02||VEP|57.8618|-152.6575|57.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-18T00:00:00|2019-12-31T23:59:59
XO|KD02||VKI|57.8618|-152.6575|57.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-05-18T00:00:00|2019-12-31T23:59:59
XO|KD02||VM1|57.8618|-152.6575|57.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-18T00:00:00|2019-12-31T23:59:59
XO|KD02||VM2|57.8618|-152.6575|57.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-18T00:00:00|2019-12-31T23:59:59
XO|KD02||VM3|57.8618|-152.6575|57.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-18T00:00:00|2019-12-31T23:59:59
XO|KD02||VPB|57.8618|-152.6575|57.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-05-18T00:00:00|2019-12-31T23:59:59
XO|KD04||ACE|57.3042|-152.8497|34.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-26T12:00:00|2019-12-31T23:59:59
XO|KD04||HHE|57.3042|-152.8497|34.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-26T12:00:00|2019-12-31T23:59:59
XO|KD04||HHN|57.3042|-152.8497|34.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-26T12:00:00|2019-12-31T23:59:59
XO|KD04||HHZ|57.3042|-152.8497|34.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-26T12:00:00|2019-12-31T23:59:59
XO|KD04||LCE|57.3042|-152.8497|34.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-05-26T12:00:00|2019-12-31T23:59:59
XO|KD04||LCQ|57.3042|-152.8497|34.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-05-26T12:00:00|2019-12-31T23:59:59
XO|KD04||LHE|57.3042|-152.8497|34.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-26T12:00:00|2019-12-31T23:59:59
XO|KD04||LHN|57.3042|-152.8497|34.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-26T12:00:00|2019-12-31T23:59:59
XO|KD04||LHZ|57.3042|-152.8497|34.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-26T12:00:00|2019-12-31T23:59:59
XO|KD04||LOG|57.3042|-152.8497|34.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-26T12:00:00|2019-12-31T23:59:59
XO|KD04||OCF|57.3042|-152.8497|34.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-26T12:00:00|2019-12-31T23:59:59
XO|KD04||VCO|57.3042|-152.8497|34.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-26T12:00:00|2019-12-31T23:59:59
XO|KD04||VEA|57.3042|-152.8497|34.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-26T12:00:00|2019-12-31T23:59:59
XO|KD04||VEC|57.3042|-152.8497|34.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-26T12:00:00|2019-12-31T23:59:59
XO|KD04||VEP|57.3042|-152.8497|34.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-26T12:00:00|2019-12-31T23:59:59
XO|KD04||VKI|57.3042|-152.8497|34.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-05-26T12:00:00|2019-12-31T23:59:59
XO|KD04||VM1|57.3042|-152.8497|34.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-26T12:00:00|2019-12-31T23:59:59
XO|KD04||VM2|57.3042|-152.8497|34.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-26T12:00:00|2019-12-31T23:59:59
XO|KD04||VM3|57.3042|-152.8497|34.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-26T12:00:00|2019-12-31T23:59:59
XO|KD04||VPB|57.3042|-152.8497|34.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-05-26T12:00:00|2019-12-31T23:59:59
XO|KD05||ACE|57.8717|-153.4099|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KD05||HHE|57.8717|-153.4099|38.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KD05||HHN|57.8717|-153.4099|38.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KD05||HHZ|57.8717|-153.4099|38.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KD05||LCE|57.8717|-153.4099|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KD05||LCQ|57.8717|-153.4099|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KD05||LHE|57.8717|-153.4099|38.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KD05||LHN|57.8717|-153.4099|38.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KD05||LHZ|57.8717|-153.4099|38.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KD05||LOG|57.8717|-153.4099|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KD05||OCF|57.8717|-153.4099|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KD05||VCO|57.8717|-153.4099|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KD05||VEA|57.8717|-153.4099|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KD05||VEC|57.8717|-153.4099|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KD05||VEP|57.8717|-153.4099|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KD05||VKI|57.8717|-153.4099|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KD05||VM1|57.8717|-153.4099|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KD05||VM2|57.8717|-153.4099|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KD05||VM3|57.8717|-153.4099|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KD05||VPB|57.8717|-153.4099|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KD12||ACE|57.313|-154.6122|90.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KD12||HHE|57.313|-154.6122|90.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KD12||HHN|57.313|-154.6122|90.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KD12||HHZ|57.313|-154.6122|90.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KD12||LCE|57.313|-154.6122|90.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KD12||LCQ|57.313|-154.6122|90.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KD12||LHE|57.313|-154.6122|90.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KD12||LHN|57.313|-154.6122|90.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KD12||LHZ|57.313|-154.6122|90.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KD12||LOG|57.313|-154.6122|90.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KD12||OCF|57.313|-154.6122|90.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KD12||VCO|57.313|-154.6122|90.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KD12||VEA|57.313|-154.6122|90.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KD12||VEC|57.313|-154.6122|90.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KD12||VEP|57.313|-154.6122|90.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KD12||VKI|57.313|-154.6122|90.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KD12||VM1|57.313|-154.6122|90.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KD12||VM2|57.313|-154.6122|90.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KD12||VM3|57.313|-154.6122|90.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KD12||VPB|57.313|-154.6122|90.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KS03||ACE|57.6133|-152.2353|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-24T12:00:00|2019-12-31T23:59:59
XO|KS03||HHE|57.6133|-152.2353|45.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-24T12:00:00|2019-12-31T23:59:59
XO|KS03||HHN|57.6133|-152.2353|45.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-24T12:00:00|2019-12-31T23:59:59
XO|KS03||HHZ|57.6133|-152.2353|45.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-24T12:00:00|2019-12-31T23:59:59
XO|KS03||HNE|57.6133|-152.2353|45.0|0.0|90.0|0.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.02|m/s**2|100.0|2018-05-24T12:00:00|2019-12-31T23:59:59
XO|KS03||HNN|57.6133|-152.2353|45.0|0.0|0.0|0.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.02|m/s**2|100.0|2018-05-24T12:00:00|2019-12-31T23:59:59
XO|KS03||HNZ|57.6133|-152.2353|45.0|0.0|0.0|-90.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.02|m/s**2|100.0|2018-05-24T12:00:00|2019-12-31T23:59:59
XO|KS03||LCE|57.6133|-152.2353|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-05-24T12:00:00|2019-12-31T23:59:59
XO|KS03||LCQ|57.6133|-152.2353|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-05-24T12:00:00|2019-12-31T23:59:59
XO|KS03||LHE|57.6133|-152.2353|45.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-24T12:00:00|2019-12-31T23:59:59
XO|KS03||LHN|57.6133|-152.2353|45.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-24T12:00:00|2019-12-31T23:59:59
XO|KS03||LHZ|57.6133|-152.2353|45.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-24T12:00:00|2019-12-31T23:59:59
XO|KS03||LNE|57.6133|-152.2353|45.0|0.0|90.0|0.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.002|m/s**2|1.0|2018-05-24T12:00:00|2019-12-31T23:59:59
XO|KS03||LNN|57.6133|-152.2353|45.0|0.0|0.0|0.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.002|m/s**2|1.0|2018-05-24T12:00:00|2019-12-31T23:59:59
XO|KS03||LNZ|57.6133|-152.2353|45.0|0.0|0.0|-90.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.002|m/s**2|1.0|2018-05-24T12:00:00|2019-12-31T23:59:59
XO|KS03||LOG|57.6133|-152.2353|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-24T12:00:00|2019-12-31T23:59:59
XO|KS03||OCF|57.6133|-152.2353|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-24T12:00:00|2019-12-31T23:59:59
XO|KS03||VCO|57.6133|-152.2353|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-24T12:00:00|2019-12-31T23:59:59
XO|KS03||VEA|57.6133|-152.2353|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-24T12:00:00|2019-12-31T23:59:59
XO|KS03||VEC|57.6133|-152.2353|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-24T12:00:00|2019-12-31T23:59:59
XO|KS03||VEP|57.6133|-152.2353|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-24T12:00:00|2019-12-31T23:59:59
XO|KS03||VKI|57.6133|-152.2353|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-05-24T12:00:00|2019-12-31T23:59:59
XO|KS03||VM1|57.6133|-152.2353|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-24T12:00:00|2019-12-31T23:59:59
XO|KS03||VM2|57.6133|-152.2353|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-24T12:00:00|2019-12-31T23:59:59
XO|KS03||VM3|57.6133|-152.2353|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-24T12:00:00|2019-12-31T23:59:59
XO|KS03||VM4|57.6133|-152.2353|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-24T12:00:00|2019-12-31T23:59:59
XO|KS03||VM5|57.6133|-152.2353|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-24T12:00:00|2019-12-31T23:59:59
XO|KS03||VM6|57.6133|-152.2353|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-24T12:00:00|2019-12-31T23:59:59
XO|KS03||VPB|57.6133|-152.2353|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-05-24T12:00:00|2019-12-31T23:59:59
XO|KS11||ACE|57.1277|-153.0879|39.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-19T12:00:00|2019-12-31T23:59:59
XO|KS11||HHE|57.1277|-153.0879|39.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-19T12:00:00|2019-12-31T23:59:59
XO|KS11||HHN|57.1277|-153.0879|39.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-19T12:00:00|2019-12-31T23:59:59
XO|KS11||HHZ|57.1277|-153.0879|39.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-19T12:00:00|2019-12-31T23:59:59
XO|KS11||HNE|57.1277|-153.0879|39.0|0.0|90.0|0.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.02|m/s**2|100.0|2018-05-19T12:00:00|2019-12-31T23:59:59
XO|KS11||HNN|57.1277|-153.0879|39.0|0.0|0.0|0.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.02|m/s**2|100.0|2018-05-19T12:00:00|2019-12-31T23:59:59
XO|KS11||HNZ|57.1277|-153.0879|39.0|0.0|0.0|-90.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.02|m/s**2|100.0|2018-05-19T12:00:00|2019-12-31T23:59:59
XO|KS11||LCE|57.1277|-153.0879|39.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-05-19T12:00:00|2019-12-31T23:59:59
XO|KS11||LCQ|57.1277|-153.0879|39.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-05-19T12:00:00|2019-12-31T23:59:59
XO|KS11||LHE|57.1277|-153.0879|39.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-19T12:00:00|2019-12-31T23:59:59
XO|KS11||LHN|57.1277|-153.0879|39.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-19T12:00:00|2019-12-31T23:59:59
XO|KS11||LHZ|57.1277|-153.0879|39.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-19T12:00:00|2019-12-31T23:59:59
XO|KS11||LNE|57.1277|-153.0879|39.0|0.0|90.0|0.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.002|m/s**2|1.0|2018-05-19T12:00:00|2019-12-31T23:59:59
XO|KS11||LNN|57.1277|-153.0879|39.0|0.0|0.0|0.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.002|m/s**2|1.0|2018-05-19T12:00:00|2019-12-31T23:59:59
XO|KS11||LNZ|57.1277|-153.0879|39.0|0.0|0.0|-90.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.002|m/s**2|1.0|2018-05-19T12:00:00|2019-12-31T23:59:59
XO|KS11||LOG|57.1277|-153.0879|39.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-19T12:00:00|2019-12-31T23:59:59
XO|KS11||OCF|57.1277|-153.0879|39.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-19T12:00:00|2019-12-31T23:59:59
XO|KS11||VCO|57.1277|-153.0879|39.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-19T12:00:00|2019-12-31T23:59:59
XO|KS11||VEA|57.1277|-153.0879|39.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-19T12:00:00|2019-12-31T23:59:59
XO|KS11||VEC|57.1277|-153.0879|39.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-19T12:00:00|2019-12-31T23:59:59
XO|KS11||VEP|57.1277|-153.0879|39.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-19T12:00:00|2019-12-31T23:59:59
XO|KS11||VKI|57.1277|-153.0879|39.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-05-19T12:00:00|2019-12-31T23:59:59
XO|KS11||VM1|57.1277|-153.0879|39.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-19T12:00:00|2019-12-31T23:59:59
XO|KS11||VM2|57.1277|-153.0879|39.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-19T12:00:00|2019-12-31T23:59:59
XO|KS11||VM3|57.1277|-153.0879|39.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-19T12:00:00|2019-12-31T23:59:59
XO|KS11||VPB|57.1277|-153.0879|39.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-05-19T12:00:00|2019-12-31T23:59:59
XO|KS13||ACE|56.9472|-154.1729|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-22T00:00:00|2019-12-31T23:59:59
XO|KS13||HHE|56.9472|-154.1729|45.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-22T00:00:00|2019-12-31T23:59:59
XO|KS13||HHN|56.9472|-154.1729|45.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-22T00:00:00|2019-12-31T23:59:59
XO|KS13||HHZ|56.9472|-154.1729|45.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-22T00:00:00|2019-12-31T23:59:59
XO|KS13||HNE|56.9472|-154.1729|45.0|0.0|90.0|0.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.02|m/s**2|100.0|2018-05-22T00:00:00|2019-12-31T23:59:59
XO|KS13||HNN|56.9472|-154.1729|45.0|0.0|0.0|0.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.02|m/s**2|100.0|2018-05-22T00:00:00|2019-12-31T23:59:59
XO|KS13||HNZ|56.9472|-154.1729|45.0|0.0|0.0|-90.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.02|m/s**2|100.0|2018-05-22T00:00:00|2019-12-31T23:59:59
XO|KS13||LCE|56.9472|-154.1729|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-05-22T00:00:00|2019-12-31T23:59:59
XO|KS13||LCQ|56.9472|-154.1729|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-05-22T00:00:00|2019-12-31T23:59:59
XO|KS13||LHE|56.9472|-154.1729|45.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-22T00:00:00|2019-12-31T23:59:59
XO|KS13||LHN|56.9472|-154.1729|45.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-22T00:00:00|2019-12-31T23:59:59
XO|KS13||LHZ|56.9472|-154.1729|45.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-22T00:00:00|2019-12-31T23:59:59
XO|KS13||LNE|56.9472|-154.1729|45.0|0.0|90.0|0.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.002|m/s**2|1.0|2018-05-22T00:00:00|2019-12-31T23:59:59
XO|KS13||LNN|56.9472|-154.1729|45.0|0.0|0.0|0.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.002|m/s**2|1.0|2018-05-22T00:00:00|2019-12-31T23:59:59
XO|KS13||LNZ|56.9472|-154.1729|45.0|0.0|0.0|-90.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.002|m/s**2|1.0|2018-05-22T00:00:00|2019-12-31T23:59:59
XO|KS13||LOG|56.9472|-154.1729|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-22T00:00:00|2019-12-31T23:59:59
XO|KS13||OCF|56.9472|-154.1729|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-22T00:00:00|2019-12-31T23:59:59
XO|KS13||VCO|56.9472|-154.1729|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-22T00:00:00|2019-12-31T23:59:59
XO|KS13||VEA|56.9472|-154.1729|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-22T00:00:00|2019-12-31T23:59:59
XO|KS13||VEC|56.9472|-154.1729|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-22T00:00:00|2019-12-31T23:59:59
XO|KS13||VEP|56.9472|-154.1729|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-22T00:00:00|2019-12-31T23:59:59
XO|KS13||VKI|56.9472|-154.1729|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-05-22T00:00:00|2019-12-31T23:59:59
XO|KS13||VM1|56.9472|-154.1729|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-22T00:00:00|2019-12-31T23:59:59
XO|KS13||VM2|56.9472|-154.1729|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-22T00:00:00|2019-12-31T23:59:59
XO|KS13||VM3|56.9472|-154.1729|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-22T00:00:00|2019-12-31T23:59:59
XO|KS13||VPB|56.9472|-154.1729|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-05-22T00:00:00|2019-12-31T23:59:59
XO|KT06||ACE|57.6517|-154.0041|46.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KT06||HHE|57.6517|-154.0041|46.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KT06||HHN|57.6517|-154.0041|46.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KT06||HHZ|57.6517|-154.0041|46.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KT06||LCE|57.6517|-154.0041|46.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KT06||LCQ|57.6517|-154.0041|46.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KT06||LHE|57.6517|-154.0041|46.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KT06||LHN|57.6517|-154.0041|46.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KT06||LHZ|57.6517|-154.0041|46.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KT06||LOG|57.6517|-154.0041|46.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KT06||OCF|57.6517|-154.0041|46.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KT06||VCO|57.6517|-154.0041|46.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KT06||VEA|57.6517|-154.0041|46.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KT06||VEC|57.6517|-154.0041|46.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KT06||VEP|57.6517|-154.0041|46.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KT06||VKI|57.6517|-154.0041|46.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KT06||VM1|57.6517|-154.0041|46.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KT06||VM2|57.6517|-154.0041|46.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KT06||VM3|57.6517|-154.0041|46.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KT06||VPB|57.6517|-154.0041|46.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-05-20T12:00:00|2019-12-31T23:59:59
XO|KT07||ACE|57.5375|-153.9814|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-22T12:00:00|2018-09-06T23:00:00
XO|KT07||ACE|57.5375|-153.9814|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-09-06T23:00:00|2019-12-31T23:59:59
XO|KT07||HHE|57.5375|-153.9814|38.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-22T12:00:00|2018-09-06T23:00:00
XO|KT07||HHE|57.5375|-153.9814|38.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-09-06T23:00:00|2019-12-31T23:59:59
XO|KT07||HHN|57.5375|-153.9814|38.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-22T12:00:00|2018-09-06T23:00:00
XO|KT07||HHN|57.5375|-153.9814|38.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-09-06T23:00:00|2019-12-31T23:59:59
XO|KT07||HHZ|57.5375|-153.9814|38.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-22T12:00:00|2018-09-06T23:00:00
XO|KT07||HHZ|57.5375|-153.9814|38.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-09-06T23:00:00|2019-12-31T23:59:59
XO|KT07||LCE|57.5375|-153.9814|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-05-22T12:00:00|2018-09-06T23:00:00
XO|KT07||LCE|57.5375|-153.9814|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-09-06T23:00:00|2019-12-31T23:59:59
XO|KT07||LCQ|57.5375|-153.9814|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-05-22T12:00:00|2018-09-06T23:00:00
XO|KT07||LCQ|57.5375|-153.9814|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-09-06T23:00:00|2019-12-31T23:59:59
XO|KT07||LHE|57.5375|-153.9814|38.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-22T12:00:00|2018-09-06T23:00:00
XO|KT07||LHE|57.5375|-153.9814|38.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-09-06T23:00:00|2019-12-31T23:59:59
XO|KT07||LHN|57.5375|-153.9814|38.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-22T12:00:00|2018-09-06T23:00:00
XO|KT07||LHN|57.5375|-153.9814|38.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-09-06T23:00:00|2019-12-31T23:59:59
XO|KT07||LHZ|57.5375|-153.9814|38.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-22T12:00:00|2018-09-06T23:00:00
XO|KT07||LHZ|57.5375|-153.9814|38.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-09-06T23:00:00|2019-12-31T23:59:59
XO|KT07||LOG|57.5375|-153.9814|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-22T12:00:00|2018-09-06T23:00:00
XO|KT07||LOG|57.5375|-153.9814|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-09-06T23:00:00|2019-12-31T23:59:59
XO|KT07||OCF|57.5375|-153.9814|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-22T12:00:00|2018-09-06T23:00:00
XO|KT07||OCF|57.5375|-153.9814|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-09-06T23:00:00|2019-12-31T23:59:59
XO|KT07||VCO|57.5375|-153.9814|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-22T12:00:00|2018-09-06T23:00:00
XO|KT07||VCO|57.5375|-153.9814|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-09-06T23:00:00|2019-12-31T23:59:59
XO|KT07||VEA|57.5375|-153.9814|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-22T12:00:00|2018-09-06T23:00:00
XO|KT07||VEA|57.5375|-153.9814|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-09-06T23:00:00|2019-12-31T23:59:59
XO|KT07||VEC|57.5375|-153.9814|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-22T12:00:00|2018-09-06T23:00:00
XO|KT07||VEC|57.5375|-153.9814|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-09-06T23:00:00|2019-12-31T23:59:59
XO|KT07||VEP|57.5375|-153.9814|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-22T12:00:00|2018-09-06T23:00:00
XO|KT07||VEP|57.5375|-153.9814|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-09-06T23:00:00|2019-12-31T23:59:59
XO|KT07||VKI|57.5375|-153.9814|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-05-22T12:00:00|2018-09-06T23:00:00
XO|KT07||VKI|57.5375|-153.9814|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-09-06T23:00:00|2019-12-31T23:59:59
XO|KT07||VM1|57.5375|-153.9814|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-22T12:00:00|2018-09-06T23:00:00
XO|KT07||VM1|57.5375|-153.9814|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-09-06T23:00:00|2019-12-31T23:59:59
XO|KT07||VM2|57.5375|-153.9814|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-22T12:00:00|2018-09-06T23:00:00
XO|KT07||VM2|57.5375|-153.9814|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-09-06T23:00:00|2019-12-31T23:59:59
XO|KT07||VM3|57.5375|-153.9814|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-22T12:00:00|2018-09-06T23:00:00
XO|KT07||VM3|57.5375|-153.9814|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-09-06T23:00:00|2019-12-31T23:59:59
XO|KT07||VPB|57.5375|-153.9814|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-05-22T12:00:00|2018-09-06T23:00:00
XO|KT07||VPB|57.5375|-153.9814|38.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-09-06T23:00:00|2019-12-31T23:59:59
XO|KT08||ACE|57.443|-153.8149|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KT08||HHE|57.443|-153.8149|41.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KT08||HHN|57.443|-153.8149|41.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KT08||HHZ|57.443|-153.8149|41.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KT08||LCE|57.443|-153.8149|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KT08||LCQ|57.443|-153.8149|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KT08||LHE|57.443|-153.8149|41.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KT08||LHN|57.443|-153.8149|41.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KT08||LHZ|57.443|-153.8149|41.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KT08||LOG|57.443|-153.8149|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KT08||OCF|57.443|-153.8149|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KT08||VCO|57.443|-153.8149|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KT08||VEA|57.443|-153.8149|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KT08||VEC|57.443|-153.8149|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KT08||VEP|57.443|-153.8149|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KT08||VKI|57.443|-153.8149|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KT08||VM1|57.443|-153.8149|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KT08||VM2|57.443|-153.8149|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KT08||VM3|57.443|-153.8149|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KT08||VPB|57.443|-153.8149|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-05-23T12:00:00|2019-12-31T23:59:59
XO|KT09||ACE|57.348|-153.7945|47.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-20T00:00:00|2019-12-31T23:59:59
XO|KT09||HHE|57.348|-153.7945|47.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-20T00:00:00|2019-12-31T23:59:59
XO|KT09||HHN|57.348|-153.7945|47.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-20T00:00:00|2019-12-31T23:59:59
XO|KT09||HHZ|57.348|-153.7945|47.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-20T00:00:00|2019-12-31T23:59:59
XO|KT09||LCE|57.348|-153.7945|47.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-05-20T00:00:00|2019-12-31T23:59:59
XO|KT09||LCQ|57.348|-153.7945|47.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-05-20T00:00:00|2019-12-31T23:59:59
XO|KT09||LHE|57.348|-153.7945|47.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-20T00:00:00|2019-12-31T23:59:59
XO|KT09||LHN|57.348|-153.7945|47.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-20T00:00:00|2019-12-31T23:59:59
XO|KT09||LHZ|57.348|-153.7945|47.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-20T00:00:00|2019-12-31T23:59:59
XO|KT09||LOG|57.348|-153.7945|47.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-20T00:00:00|2019-12-31T23:59:59
XO|KT09||OCF|57.348|-153.7945|47.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-20T00:00:00|2019-12-31T23:59:59
XO|KT09||VCO|57.348|-153.7945|47.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-20T00:00:00|2019-12-31T23:59:59
XO|KT09||VEA|57.348|-153.7945|47.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-20T00:00:00|2019-12-31T23:59:59
XO|KT09||VEC|57.348|-153.7945|47.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-20T00:00:00|2019-12-31T23:59:59
XO|KT09||VEP|57.348|-153.7945|47.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-20T00:00:00|2019-12-31T23:59:59
XO|KT09||VKI|57.348|-153.7945|47.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-05-20T00:00:00|2019-12-31T23:59:59
XO|KT09||VM1|57.348|-153.7945|47.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-20T00:00:00|2019-12-31T23:59:59
XO|KT09||VM2|57.348|-153.7945|47.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-20T00:00:00|2019-12-31T23:59:59
XO|KT09||VM3|57.348|-153.7945|47.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-20T00:00:00|2019-12-31T23:59:59
XO|KT09||VPB|57.348|-153.7945|47.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-05-20T00:00:00|2019-12-31T23:59:59
XO|KT10||ACE|57.295|-153.66|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-21T00:00:00|2019-09-29T01:00:00
XO|KT10||HHE|57.295|-153.66|43.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-21T00:00:00|2019-09-29T01:00:00
XO|KT10||HHN|57.295|-153.66|43.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-21T00:00:00|2019-09-29T01:00:00
XO|KT10||HHZ|57.295|-153.66|43.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-21T00:00:00|2019-09-29T01:00:00
XO|KT10||LCE|57.295|-153.66|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-05-21T00:00:00|2019-09-29T01:00:00
XO|KT10||LCQ|57.295|-153.66|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-05-21T00:00:00|2019-09-29T01:00:00
XO|KT10||LHE|57.295|-153.66|43.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-21T00:00:00|2019-09-29T01:00:00
XO|KT10||LHN|57.295|-153.66|43.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-21T00:00:00|2019-09-29T01:00:00
XO|KT10||LHZ|57.295|-153.66|43.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-21T00:00:00|2019-09-29T01:00:00
XO|KT10||LOG|57.295|-153.66|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-21T00:00:00|2019-09-29T01:00:00
XO|KT10||OCF|57.295|-153.66|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-21T00:00:00|2019-09-29T01:00:00
XO|KT10||VCO|57.295|-153.66|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-21T00:00:00|2019-09-29T01:00:00
XO|KT10||VEA|57.295|-153.66|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-21T00:00:00|2019-09-29T01:00:00
XO|KT10||VEC|57.295|-153.66|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-21T00:00:00|2019-09-29T01:00:00
XO|KT10||VEP|57.295|-153.66|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-21T00:00:00|2019-09-29T01:00:00
XO|KT10||VKI|57.295|-153.66|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-05-21T00:00:00|2019-09-29T01:00:00
XO|KT10||VM1|57.295|-153.66|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-21T00:00:00|2019-09-29T01:00:00
XO|KT10||VM2|57.295|-153.66|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-21T00:00:00|2019-09-29T01:00:00
XO|KT10||VM3|57.295|-153.66|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-21T00:00:00|2019-09-29T01:00:00
XO|KT10||VPB|57.295|-153.66|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-05-21T00:00:00|2019-09-29T01:00:00
XO|LA21||EDH|54.3691|-155.0735|-5113.0|0.0|0.0|90.0|LDEO HTI90U/LDEO OBS 2011 logger|359.191|2.0|Pa|100.0|2018-05-22T00:00:00|2019-08-26T23:59:59
XO|LA21||HDH|54.3691|-155.0735|-5113.0|0.0|0.0|-90.0|Parosci APG Pressure/LDEO_APG_logger|99.7254|0.08|Pa|125.0|2018-05-22T00:00:00|2019-08-26T23:59:59
XO|LA21||HH1|54.3691|-155.0735|-5113.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-22T00:00:00|2019-08-26T23:59:59
XO|LA21||HH2|54.3691|-155.0735|-5113.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-22T00:00:00|2019-08-26T23:59:59
XO|LA21||HHZ|54.3691|-155.0735|-5113.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-22T00:00:00|2019-08-26T23:59:59
XO|LA21||HKO|54.3691|-155.0735|-5113.0|0.0|0.0|-90.0|Parosci APG Temperature/LDEO_APG logger|1000.0|10.0|degC|125.0|2018-05-22T00:00:00|2019-08-26T23:59:59
XO|LA22||EDH|55.2576|-155.153|-2130.0|0.0|0.0|90.0|LDEO HTI90U/LDEO OBS 2011 logger|359.191|2.0|Pa|100.0|2018-05-23T00:00:00|2019-08-27T23:59:59
XO|LA22||HDH|55.2576|-155.153|-2130.0|0.0|0.0|-90.0|Parosci APG Pressure/LDEO_APG_logger|99.7254|0.08|Pa|125.0|2018-05-23T00:00:00|2019-08-27T23:59:59
XO|LA22||HKO|55.2576|-155.153|-2130.0|0.0|0.0|-90.0|Parosci APG Temperature/LDEO_APG logger|1000.0|10.0|degC|125.0|2018-05-23T00:00:00|2019-08-27T23:59:59
XO|LA22|AN|RKO|55.257568|-155.152951|-2130.0|0.0|0.0|0.0|LDEO/APG-3145|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-24T00:20:00|2019-07-30T23:40:00
XO|LA23||EDH|54.9163|-155.2376|-3977.0|0.0|0.0|90.0|LDEO HTI90U/LDEO OBS 2011 logger|359.191|2.0|Pa|100.0|2018-05-23T00:00:00|2019-08-26T23:59:59
XO|LA23||HDH|54.9163|-155.2376|-3977.0|0.0|0.0|-90.0|Parosci APG Pressure/LDEO_APG_logger|99.7254|0.08|Pa|125.0|2018-05-23T00:00:00|2019-08-26T23:59:59
XO|LA23||HH1|54.9163|-155.2376|-3977.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-23T00:00:00|2019-08-26T23:59:59
XO|LA23||HH2|54.9163|-155.2376|-3977.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-23T00:00:00|2019-08-26T23:59:59
XO|LA23||HHZ|54.9163|-155.2376|-3977.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-23T00:00:00|2019-08-26T23:59:59
XO|LA23||HKO|54.9163|-155.2376|-3977.0|0.0|0.0|-90.0|Parosci APG Temperature/LDEO_APG logger|1000.0|10.0|degC|125.0|2018-05-23T00:00:00|2019-08-26T23:59:59
XO|LA23|AN|RKO|54.916341|-155.237562|-3967.0|0.0|0.0|0.0|LDEO/APG-3151|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-24T00:20:00|2019-07-30T23:40:00
XO|LA25||EDH|54.8901|-155.9408|-2622.0|0.0|0.0|90.0|LDEO HTI90U/LDEO OBS 2011 logger|359.191|2.0|Pa|100.0|2018-05-14T00:00:00|2019-08-20T23:59:59
XO|LA25||HDH|54.8901|-155.9408|-2622.0|0.0|0.0|-90.0|Parosci APG Pressure/LDEO_APG_logger|99.7254|0.08|Pa|125.0|2018-05-14T00:00:00|2019-08-20T23:59:59
XO|LA25||HH1|54.8901|-155.9408|-2622.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-14T00:00:00|2019-08-20T23:59:59
XO|LA25||HH2|54.8901|-155.9408|-2622.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-14T00:00:00|2019-08-20T23:59:59
XO|LA25||HHZ|54.8901|-155.9408|-2622.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-14T00:00:00|2019-08-20T23:59:59
XO|LA25||HKO|54.8901|-155.9408|-2622.0|0.0|0.0|-90.0|Parosci APG Temperature/LDEO_APG logger|1000.0|10.0|degC|125.0|2018-05-14T00:00:00|2019-08-20T23:59:59
XO|LA25|AN|RKO|54.89005|-155.940841|-2622.0|0.0|0.0|0.0|LDEO/APG-3141|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-15T00:20:00|2019-07-30T23:40:00
XO|LA26||EDH|54.5129|-156.2561|-5103.0|0.0|0.0|90.0|LDEO HTI90U/LDEO OBS 2011 logger|359.191|2.0|Pa|100.0|2018-05-22T00:00:00|2019-08-20T23:59:59
XO|LA26||HDH|54.5129|-156.2561|-5103.0|0.0|0.0|-90.0|Parosci APG Pressure/LDEO_APG_logger|99.7254|0.08|Pa|125.0|2018-05-22T00:00:00|2019-08-20T23:59:59
XO|LA26||HH1|54.5129|-156.2561|-5103.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-22T00:00:00|2019-08-20T23:59:59
XO|LA26||HH2|54.5129|-156.2561|-5103.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-22T00:00:00|2019-08-20T23:59:59
XO|LA26||HHZ|54.5129|-156.2561|-5103.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-22T00:00:00|2019-08-20T23:59:59
XO|LA26||HKO|54.5129|-156.2561|-5103.0|0.0|0.0|-90.0|Parosci APG Temperature/LDEO_APG logger|1000.0|10.0|degC|125.0|2018-05-22T00:00:00|2019-08-20T23:59:59
XO|LA28||EDH|54.8983|-156.603|-1852.0|0.0|0.0|90.0|LDEO HTI90U/LDEO OBS 2011 logger|359.191|2.0|Pa|100.0|2018-05-14T00:00:00|2019-08-20T23:59:59
XO|LA28||HDH|54.8983|-156.603|-1852.0|0.0|0.0|-90.0|Parosci APG Pressure/LDEO_APG_logger|99.7254|0.08|Pa|125.0|2018-05-14T00:00:00|2019-08-20T23:59:59
XO|LA28||HH1|54.8983|-156.603|-1852.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-14T00:00:00|2019-08-20T23:59:59
XO|LA28||HH2|54.8983|-156.603|-1852.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-14T00:00:00|2019-08-20T23:59:59
XO|LA28||HHZ|54.8983|-156.603|-1852.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-14T00:00:00|2019-08-20T23:59:59
XO|LA28||HKO|54.8983|-156.603|-1852.0|0.0|0.0|-90.0|Parosci APG Temperature/LDEO_APG logger|1000.0|10.0|degC|125.0|2018-05-14T00:00:00|2019-08-20T23:59:59
XO|LA29||EDH|54.2918|-157.3705|-4408.0|0.0|0.0|90.0|LDEO HTI90U/LDEO OBS 2011 logger|359.191|2.0|Pa|100.0|2018-05-21T00:00:00|2019-08-26T23:59:59
XO|LA29||HDH|54.292|-157.367|-4424.0|0.0|0.0|-90.0|Parosci APG Pressure/LDEO_APG_logger|99.7254|0.08|Pa|125.0|2018-05-21T00:00:00|2019-08-26T23:59:59
XO|LA29||HH1|54.2918|-157.3705|-4408.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-21T00:00:00|2019-08-26T23:59:59
XO|LA29||HH2|54.2918|-157.3705|-4408.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-21T00:00:00|2019-08-26T23:59:59
XO|LA29||HHZ|54.2918|-157.3705|-4408.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-21T00:00:00|2019-08-26T23:59:59
XO|LA29|AN|RKO|54.29184|-157.370453|-4408.0|0.0|0.0|0.0|LDEO/APG-3069|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-22T00:20:00|2019-07-30T23:40:00
XO|LA30||EDH|54.6727|-157.4203|-1564.0|0.0|0.0|90.0|LDEO HTI90U/LDEO OBS 2011 logger|359.191|2.0|Pa|100.0|2018-05-14T00:00:00|2019-08-21T23:59:59
XO|LA30||HDH|54.6727|-157.4203|-1564.0|0.0|0.0|-90.0|Parosci APG Pressure/LDEO_APG_logger|99.7254|0.08|Pa|125.0|2018-05-14T00:00:00|2019-08-21T23:59:59
XO|LA30||HH1|54.6727|-157.4203|-1564.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-14T00:00:00|2019-08-21T23:59:59
XO|LA30||HH2|54.6727|-157.4203|-1564.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-14T00:00:00|2019-08-21T23:59:59
XO|LA30||HHZ|54.6727|-157.4203|-1564.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-14T00:00:00|2019-08-21T23:59:59
XO|LA30||HKO|54.6727|-157.4203|-1564.0|0.0|0.0|-90.0|Parosci APG Temperature/LDEO_APG logger|1000.0|10.0|degC|125.0|2018-05-14T00:00:00|2019-08-21T23:59:59
XO|LA30|SO|RKO|54.672698|-157.420323|-1564.0|0.0|0.0|0.0|LDEO/APG-3144|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-16T00:10:00|2019-08-19T23:50:00
XO|LA32||EDH|54.4982|-157.8522|-1595.0|0.0|0.0|90.0|LDEO HTI90U/LDEO OBS 2011 logger|359.191|2.0|Pa|100.0|2018-05-15T00:00:00|2019-08-21T23:59:59
XO|LA32||HDH|54.4982|-157.8522|-1595.0|0.0|0.0|-90.0|Parosci APG Pressure/LDEO_APG_logger|99.7254|0.08|Pa|125.0|2018-05-15T00:00:00|2019-08-21T23:59:59
XO|LA32||HH1|54.4982|-157.8522|-1595.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-15T00:00:00|2019-08-21T23:59:59
XO|LA32||HH2|54.4982|-157.8522|-1595.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-15T00:00:00|2019-08-21T23:59:59
XO|LA32||HHZ|54.4982|-157.8522|-1595.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-15T00:00:00|2019-08-21T23:59:59
XO|LA32||HKO|54.4982|-157.8522|-1595.0|0.0|0.0|-90.0|Parosci APG Temperature/LDEO_APG logger|1000.0|10.0|degC|125.0|2018-05-15T00:00:00|2019-08-21T23:59:59
XO|LA32|SO|RKO|54.498254|-157.852213|-1595.0|0.0|0.0|0.0|LDEO/APG-3140|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-16T00:10:00|2019-08-19T23:50:00
XO|LA33||EDH|54.1528|-158.1143|-4478.0|0.0|0.0|90.0|LDEO HTI90U/LDEO OBS 2011 logger|359.191|2.0|Pa|100.0|2018-05-21T00:00:00|2019-08-25T23:59:59
XO|LA33||HDH|54.1528|-158.1143|-4478.0|0.0|0.0|-90.0|Parosci APG Pressure/LDEO_APG_logger|99.7254|0.08|Pa|125.0|2018-05-21T00:00:00|2019-08-25T23:59:59
XO|LA33||HH1|54.1528|-158.1143|-4478.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-21T00:00:00|2019-08-25T23:59:59
XO|LA33||HH2|54.1528|-158.1143|-4478.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-21T00:00:00|2019-08-25T23:59:59
XO|LA33||HHZ|54.1528|-158.1143|-4478.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-21T00:00:00|2019-08-25T23:59:59
XO|LA33||HKO|54.1528|-158.1143|-4478.0|0.0|0.0|-90.0|Parosci APG Temperature/LDEO_APG logger|1000.0|10.0|degC|125.0|2018-05-21T00:00:00|2019-08-25T23:59:59
XO|LA33|AN|RKO|54.152771|-158.114296|-4478.0|0.0|0.0|0.0|LDEO/APG-3066|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-22T00:20:00|2019-07-30T23:40:00
XO|LA34||EDH|54.0449|-158.5881|-4612.0|0.0|0.0|90.0|LDEO HTI90U/LDEO OBS 2011 logger|359.191|2.0|Pa|100.0|2018-05-20T00:00:00|2019-08-25T23:59:59
XO|LA34||HDH|54.0449|-158.5881|-4612.0|0.0|0.0|-90.0|Parosci APG Pressure/LDEO_APG_logger|99.7254|0.08|Pa|125.0|2018-05-20T00:00:00|2019-08-25T23:59:59
XO|LA34||HH1|54.0449|-158.5881|-4612.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-20T00:00:00|2019-08-25T23:59:59
XO|LA34||HH2|54.0449|-158.5881|-4612.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-20T00:00:00|2019-08-25T23:59:59
XO|LA34||HHZ|54.0449|-158.5881|-4612.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-20T00:00:00|2019-08-25T23:59:59
XO|LA34||HKO|54.0449|-158.5881|-4612.0|0.0|0.0|-90.0|Parosci APG Temperature/LDEO_APG logger|1000.0|10.0|degC|125.0|2018-05-20T00:00:00|2019-08-25T23:59:59
XO|LA34|AN|RKO|54.044897|-158.588083|-4612.0|0.0|0.0|0.0|LDEO/APG-3068|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-21T00:20:00|2019-07-30T23:40:00
XO|LA39||EDH|56.8827|-151.0011|-1628.0|0.0|0.0|90.0|LDEO HTI90U/LDEO OBS 2011 logger|359.191|2.0|Pa|100.0|2018-05-27T00:00:00|2019-08-11T23:59:59
XO|LA39||HDH|56.8827|-151.0011|-1628.0|0.0|0.0|-90.0|Parosci APG Pressure/LDEO_APG_logger|99.7254|0.08|Pa|125.0|2018-05-27T00:00:00|2019-08-11T23:59:59
XO|LA39||HH1|56.8827|-151.0011|-1628.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-27T00:00:00|2019-08-11T23:59:59
XO|LA39||HH2|56.8827|-151.0011|-1628.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-27T00:00:00|2019-08-11T23:59:59
XO|LA39||HHZ|56.8827|-151.0011|-1628.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-27T00:00:00|2019-08-11T23:59:59
XO|LA39||HKO|56.8827|-151.0011|-1628.0|0.0|0.0|-90.0|Parosci APG Temperature/LDEO_APG logger|1000.0|10.0|degC|125.0|2018-05-27T00:00:00|2019-08-11T23:59:59
XO|LA39|SO|RKO|56.882703|-151.001099|-1628.0|0.0|0.0|0.0|LDEO/DPG-3136|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-28T00:10:00|2019-08-09T23:50:00
XO|LA39|T1|RKO|56.882703|-151.001099|-1628.0|0.0|0.0|0.0|LDEO/DPG-3136|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-28T00:10:00|2019-08-09T23:50:00
XO|LA39|T2|RKO|56.882703|-151.001099|-1628.0|0.0|0.0|0.0|LDEO/DPG-3136Temperature|1.0|3.125E-4|celsius|8.3333E-4|2018-05-28T00:10:00|2019-08-09T23:50:00
XO|LD35||HDH|54.2495|-158.872|-1993.0|0.0|0.0|-90.0|LDEO DPG/LDEO OBS 2011 logger|166.968|0.3|Pa|100.0|2018-05-16T00:00:00|2019-08-25T23:59:59
XO|LD35||HH1|54.2495|-158.872|-1993.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-16T00:00:00|2019-08-25T23:59:59
XO|LD35||HH2|54.2495|-158.872|-1993.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-16T00:00:00|2019-08-25T23:59:59
XO|LD35||HHZ|54.2495|-158.872|-1993.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-16T00:00:00|2019-08-25T23:59:59
XO|LD35|SO|RKO|54.249511|-158.871991|-1993.0|0.0|0.0|0.0|LDEO/DPG-3166|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-17T00:10:00|2019-08-23T23:50:00
XO|LD35|T1|RKO|54.249511|-158.871991|-1993.0|0.0|0.0|0.0|LDEO/DPG-3166|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-17T00:10:00|2019-08-22T23:50:00
XO|LD35|T2|RKO|54.249511|-158.871991|-1993.0|0.0|0.0|0.0|LDEO/DPG-3166Temperature|1.0|3.125E-4|celsius|8.3333E-4|2018-05-17T00:10:00|2019-08-22T23:50:00
XO|LD36||HDH|55.2524|-155.7525|-935.0|0.0|0.0|-90.0|LDEO DPG/LDEO OBS 2011 logger|166.968|0.3|Pa|100.0|2018-05-14T00:00:00|2019-08-20T23:59:59
XO|LD36||HH1|55.2524|-155.7525|-935.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-14T00:00:00|2019-08-20T23:59:59
XO|LD36||HH2|55.2524|-155.7525|-935.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-14T00:00:00|2019-08-20T23:59:59
XO|LD36||HHZ|55.2524|-155.7525|-935.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-14T00:00:00|2019-08-20T23:59:59
XO|LD36|AN|RKO|55.252416|-155.752458|-935.0|0.0|0.0|0.0|LDEO/DPG-3079|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-15T00:20:00|2019-07-30T23:40:00
XO|LD36|T1|RKO|55.252416|-155.752458|-935.0|0.0|0.0|0.0|LDEO/DPG-3079|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-15T00:10:00|2019-08-17T23:50:00
XO|LD36|T2|RKO|55.252416|-155.752458|-935.0|0.0|0.0|0.0|LDEO/DPG-3079Temperature|1.0|3.125E-4|celsius|8.3333E-4|2018-05-15T00:10:00|2019-08-17T23:50:00
XO|LD37||HDH|55.6764|-151.1005|-4826.0|0.0|0.0|-90.0|LDEO DPG/LDEO OBS 2011 logger|166.968|0.3|Pa|100.0|2018-05-25T00:00:00|2019-08-28T23:59:59
XO|LD37||HH1|55.6764|-151.1005|-4826.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-25T00:00:00|2019-08-28T23:59:59
XO|LD37||HH2|55.6764|-151.1005|-4826.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-25T00:00:00|2019-08-28T23:59:59
XO|LD37||HHZ|55.6764|-151.1005|-4826.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-25T00:00:00|2019-08-28T23:59:59
XO|LD37|AN|RKO|55.676425|-151.100481|-4826.0|0.0|0.0|0.0|LDEO/DPG-3167|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-27T00:20:00|2019-07-30T23:40:00
XO|LD37|T1|RKO|55.676425|-151.100481|-4826.0|0.0|0.0|0.0|LDEO/DPG-3167|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-26T00:10:00|2019-08-25T23:50:00
XO|LD37|T2|RKO|55.676425|-151.100481|-4826.0|0.0|0.0|0.0|LDEO/DPG-3167Temperature|1.0|3.125E-4|celsius|8.3333E-4|2018-05-26T00:10:00|2019-08-25T23:50:00
XO|LD38||HDH|55.1649|-151.6756|-4043.0|0.0|0.0|-90.0|LDEO DPG/LDEO OBS 2011 logger|166.968|0.3|Pa|100.0|2018-05-25T00:00:00|2019-08-28T23:59:59
XO|LD38||HH1|55.1649|-151.6756|-4043.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-25T00:00:00|2019-08-28T23:59:59
XO|LD38||HH2|55.1649|-151.6756|-4043.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-25T00:00:00|2019-08-28T23:59:59
XO|LD38||HHZ|55.1649|-151.6756|-4043.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-25T00:00:00|2019-08-28T23:59:59
XO|LD38|T1|RKO|55.164906|-151.675604|-4043.0|0.0|0.0|0.0|LDEO/DPG-3162|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-26T00:10:00|2019-08-24T23:50:00
XO|LD40||HDH|56.3037|-152.4102|-1055.0|0.0|0.0|-90.0|LDEO DPG/LDEO OBS 2011 logger|166.968|0.3|Pa|100.0|2018-05-25T00:00:00|2019-08-13T23:59:59
XO|LD40||HH1|56.3037|-152.4102|-1055.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-25T00:00:00|2019-08-13T23:59:59
XO|LD40||HH2|56.3037|-152.4102|-1055.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-25T00:00:00|2019-08-13T23:59:59
XO|LD40||HHZ|56.3037|-152.4102|-1055.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-25T00:00:00|2019-08-13T23:59:59
XO|LD40|SO|RKO|56.30374|-152.410232|-1055.0|0.0|0.0|0.0|LDEO/DPG-3133|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-26T00:10:00|2019-08-11T23:50:00
XO|LD40|T1|RKO|56.30374|-152.410232|-1055.0|0.0|0.0|0.0|LDEO/DPG-3133|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-25T00:10:00|2019-08-11T23:50:00
XO|LD40|T2|RKO|56.30374|-152.410232|-1055.0|0.0|0.0|0.0|LDEO/DPG-3133Temperature|1.0|3.125E-4|celsius|8.3333E-4|2018-05-25T00:10:00|2019-08-11T23:50:00
XO|LD41||HDH|54.5219|-153.4074|-4284.0|0.0|0.0|-90.0|LDEO DPG/LDEO OBS 2011 logger|166.968|0.3|Pa|100.0|2018-05-23T00:00:00|2019-08-27T23:59:59
XO|LD41||HH1|54.5219|-153.4074|-4284.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-23T00:00:00|2019-08-27T23:59:59
XO|LD41||HH2|54.5219|-153.4074|-4284.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-23T00:00:00|2019-08-27T23:59:59
XO|LD41||HHZ|54.5219|-153.4074|-4284.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-23T00:00:00|2019-08-27T23:59:59
XO|LD41|T1|RKO|54.521943|-153.40736|-4284.0|0.0|0.0|0.0|LDEO/DPG-3086|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-23T00:10:00|2019-08-25T23:50:00
XO|LD42|SO|RKO|55.549885|-154.671428|-969.0|0.0|0.0|0.0|LDEO/DPG-3134|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-25T00:10:00|2019-08-25T23:50:00
XO|LD42|T1|RKO|55.549885|-154.671428|-969.0|0.0|0.0|0.0|LDEO/DPG-3134|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-24T00:10:00|2019-08-24T23:50:00
XO|LD42|T2|RKO|55.549885|-154.671428|-969.0|0.0|0.0|0.0|LDEO/DPG-3134Temperature|1.0|3.125E-4|celsius|8.3333E-4|2018-05-24T00:10:00|2019-08-24T23:50:00
XO|LD44||HDH|53.8302|-159.7736|-4675.0|0.0|0.0|-90.0|LDEO DPG/LDEO OBS 2011 logger|166.968|0.3|Pa|100.0|2018-05-20T00:00:00|2019-08-24T23:59:59
XO|LD44||HH1|53.8302|-159.7736|-4675.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-20T00:00:00|2019-08-24T23:59:59
XO|LD44||HH2|53.8302|-159.7736|-4675.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-20T00:00:00|2019-08-24T23:59:59
XO|LD44||HHZ|53.8302|-159.7736|-4675.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-20T00:00:00|2019-08-24T23:59:59
XO|LD44|T1|RKO|53.830194|-159.77362|-4675.0|0.0|0.0|0.0|LDEO/DPG-3085|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-21T00:10:00|2019-08-22T23:50:00
XO|LD45||HDH|54.1025|-159.8829|-2019.0|0.0|0.0|-90.0|LDEO DPG/LDEO OBS 2011 logger|166.968|0.3|Pa|100.0|2018-05-20T00:00:00|2019-08-24T23:59:59
XO|LD45||HH1|54.1025|-159.8829|-2019.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-20T00:00:00|2019-08-24T23:59:59
XO|LD45||HH2|54.1025|-159.8829|-2019.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-20T00:00:00|2019-08-24T23:59:59
XO|LD45||HHZ|54.1025|-159.8829|-2019.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-20T00:00:00|2019-08-24T23:59:59
XO|LD45|SO|RKO|54.102518|-159.882909|-2019.0|0.0|0.0|0.0|LDEO/DPG-3165|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-21T00:10:00|2019-08-22T23:50:00
XO|LD45|T1|RKO|54.102518|-159.882909|-2019.0|0.0|0.0|0.0|LDEO/DPG-3165|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-21T00:10:00|2019-08-22T23:50:00
XO|LD45|T2|RKO|54.102518|-159.882909|-2019.0|0.0|0.0|0.0|LDEO/DPG-3165Temperature|1.0|3.125E-4|celsius|8.3333E-4|2018-05-21T00:10:00|2019-08-22T23:50:00
XO|LT01||EDH|56.7756|-152.5228|-156.0|0.0|0.0|90.0|LDEO HTI90U/LDEO OBS 2011 logger|359.191|2.0|Pa|100.0|2018-05-24T00:00:00|2019-08-14T23:59:59
XO|LT01||HDH|56.7756|-152.5228|-156.0|0.0|0.0|-90.0|Parosci APG Pressure/LDEO_APG_logger|99.7254|0.08|Pa|125.0|2018-05-24T00:00:00|2019-08-14T23:59:59
XO|LT01||HH1|56.7756|-152.5228|-156.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-24T00:00:00|2019-08-14T23:59:59
XO|LT01||HH2|56.7756|-152.5228|-156.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-24T00:00:00|2019-08-14T23:59:59
XO|LT01||HHZ|56.7756|-152.5228|-156.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-24T00:00:00|2019-08-14T23:59:59
XO|LT01||HKO|56.7756|-152.5228|-156.0|0.0|0.0|-90.0|Parosci APG Temperature/LDEO_APG logger|1000.0|10.0|degC|125.0|2018-05-24T00:00:00|2019-08-14T23:59:59
XO|LT01|SO|RKO|56.775555|-152.522757|-156.0|0.0|0.0|0.0|LDEO/TRM-3142|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-25T00:10:00|2019-08-11T23:50:00
XO|LT02||EDH|56.6932|-153.2611|-152.0|0.0|0.0|90.0|LDEO HTI90U/LDEO OBS 2011 logger|359.191|2.0|Pa|100.0|2018-05-24T00:00:00|2019-08-28T23:59:59
XO|LT02||HDH|56.6932|-153.2611|-152.0|0.0|0.0|-90.0|Parosci APG Pressure/LDEO_APG_logger|99.7254|0.08|Pa|125.0|2018-05-24T00:00:00|2019-08-28T23:59:59
XO|LT02||HH1|56.6932|-153.2611|-152.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-24T00:00:00|2019-08-28T23:59:59
XO|LT02||HH2|56.6932|-153.2611|-152.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-24T00:00:00|2019-08-28T23:59:59
XO|LT02||HHZ|56.6932|-153.2611|-152.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-24T00:00:00|2019-08-28T23:59:59
XO|LT02||HKO|56.6932|-153.2611|-152.0|0.0|0.0|-90.0|Parosci APG Temperature/LDEO_APG logger|1000.0|10.0|degC|125.0|2018-05-24T00:00:00|2019-08-28T23:59:59
XO|LT02|SO|RKO|56.693216|-153.261046|-152.0|0.0|0.0|0.0|LDEO/TRM-3159|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-25T00:10:00|2019-08-11T23:50:00
XO|LT03||EDH|57.8668|-154.1665|-202.0|0.0|0.0|90.0|LDEO HTI90U/LDEO OBS 2011 logger|359.191|2.0|Pa|100.0|2018-05-10T00:00:00|2019-08-15T23:59:59
XO|LT03||HDH|57.8668|-154.1665|-202.0|0.0|0.0|-90.0|Parosci APG Pressure/LDEO_APG_logger|99.7254|0.08|Pa|125.0|2018-05-10T00:00:00|2019-08-15T23:59:59
XO|LT03||HH1|57.8668|-154.1665|-202.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-10T00:00:00|2019-08-15T23:59:59
XO|LT03||HH2|57.8668|-154.1665|-202.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-10T00:00:00|2019-08-15T23:59:59
XO|LT03||HHZ|57.8668|-154.1665|-202.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-10T00:00:00|2019-08-15T23:59:59
XO|LT03||HKO|57.8668|-154.1665|-202.0|0.0|0.0|-90.0|Parosci APG Temperature/LDEO_APG logger|1000.0|10.0|degC|125.0|2018-05-10T00:00:00|2019-08-15T23:59:59
XO|LT03|SO|RKO|57.8668|-154.1665|-202.0|0.0|0.0|0.0|LDEO/TRM-3139|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-11T00:10:00|2019-08-13T23:50:00
XO|LT04||EDH|56.1118|-154.4446|-157.0|0.0|0.0|90.0|LDEO HTI90U/LDEO OBS 2011 logger|359.191|2.0|Pa|100.0|2018-05-24T00:00:00|2019-08-14T23:59:59
XO|LT04||HDH|56.1118|-154.4446|-157.0|0.0|0.0|-90.0|Parosci APG Pressure/LDEO_APG_logger|99.7254|0.08|Pa|125.0|2018-05-24T00:00:00|2019-08-14T23:59:59
XO|LT04||HH1|56.1118|-154.4446|-157.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-24T00:00:00|2019-08-14T23:59:59
XO|LT04||HH2|56.1118|-154.4446|-157.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-24T00:00:00|2019-08-14T23:59:59
XO|LT04||HHZ|56.1118|-154.4446|-157.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-24T00:00:00|2019-08-14T23:59:59
XO|LT04||HKO|56.1118|-154.4446|-157.0|0.0|0.0|-90.0|Parosci APG Temperature/LDEO_APG logger|1000.0|10.0|degC|125.0|2018-05-24T00:00:00|2019-08-14T23:59:59
XO|LT04|SO|RKO|56.111769|-154.444618|-157.0|0.0|0.0|0.0|LDEO/TRM-|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-25T00:10:00|2019-08-12T23:50:00
XO|LT05||EDH|56.823|-155.3469|-236.0|0.0|0.0|90.0|LDEO HTI90U/LDEO OBS 2011 logger|359.191|2.0|Pa|100.0|2018-05-11T00:00:00|2019-08-15T23:59:59
XO|LT05||HDH|56.823|-155.3469|-236.0|0.0|0.0|-90.0|Parosci APG Pressure/LDEO_APG_logger|99.7254|0.08|Pa|125.0|2018-05-11T00:00:00|2019-08-15T23:59:59
XO|LT05||HH1|56.823|-155.3469|-236.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-11T00:00:00|2019-08-15T23:59:59
XO|LT05||HH2|56.823|-155.3469|-236.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-11T00:00:00|2019-08-15T23:59:59
XO|LT05||HHZ|56.823|-155.3469|-236.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-11T00:00:00|2019-08-15T23:59:59
XO|LT05||HKO|56.823|-155.3469|-236.0|0.0|0.0|-90.0|Parosci APG Temperature/LDEO_APG logger|1000.0|10.0|degC|125.0|2018-05-11T00:00:00|2019-08-15T23:59:59
XO|LT05|SO|RKO|56.823024|-155.346907|-236.0|0.0|0.0|0.0|LDEO/TRM-3056|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-12T00:10:00|2019-08-13T23:50:00
XO|LT06||EDH|56.2167|-155.9979|-225.0|0.0|0.0|90.0|LDEO HTI90U/LDEO OBS 2011 logger|359.191|2.0|Pa|100.0|2018-05-12T00:00:00|2019-08-17T23:59:59
XO|LT06||HDH|56.2167|-155.9979|-225.0|0.0|0.0|-90.0|Parosci APG Pressure/LDEO_APG_logger|99.7254|0.08|Pa|125.0|2018-05-12T00:00:00|2019-08-17T23:59:59
XO|LT06||HH1|56.2167|-155.9979|-225.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-12T00:00:00|2019-08-17T23:59:59
XO|LT06||HH2|56.2167|-155.9979|-225.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-12T00:00:00|2019-08-17T23:59:59
XO|LT06||HHZ|56.2167|-155.9979|-225.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-12T00:00:00|2019-08-17T23:59:59
XO|LT06||HKO|56.2167|-155.9979|-225.0|0.0|0.0|-90.0|Parosci APG Temperature/LDEO_APG logger|1000.0|10.0|degC|125.0|2018-05-12T00:00:00|2019-08-17T23:59:59
XO|LT06|SO|RKO|56.21666|-155.9979|-225.0|0.0|0.0|0.0|LDEO/TRM-3143|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-13T00:10:00|2019-08-14T23:50:00
XO|LT07||EDH|56.6712|-156.1199|-262.0|0.0|0.0|90.0|LDEO HTI90U/LDEO OBS 2011 logger|359.191|2.0|Pa|100.0|2018-05-11T00:00:00|2019-08-15T23:59:59
XO|LT07||HDH|56.6712|-156.1199|-262.0|0.0|0.0|-90.0|Parosci APG Pressure/LDEO_APG_logger|99.7254|0.08|Pa|125.0|2018-05-11T00:00:00|2019-08-15T23:59:59
XO|LT07||HH1|56.6712|-156.1199|-262.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-11T00:00:00|2019-08-15T23:59:59
XO|LT07||HH2|56.6712|-156.1199|-262.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-11T00:00:00|2019-08-15T23:59:59
XO|LT07||HHZ|56.6712|-156.1199|-262.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-11T00:00:00|2019-08-15T23:59:59
XO|LT07||HKO|56.6712|-156.1199|-262.0|0.0|0.0|-90.0|Parosci APG Temperature/LDEO_APG logger|1000.0|10.0|degC|125.0|2018-05-11T00:00:00|2019-08-15T23:59:59
XO|LT07|SO|RKO|56.671183|-156.119948|-262.0|0.0|0.0|0.0|LDEO/TRM-3146|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-13T00:10:00|2019-08-13T23:50:00
XO|LT08||EDH|55.5883|-156.5975|-246.0|0.0|0.0|90.0|LDEO HTI90U/LDEO OBS 2011 logger|359.191|2.0|Pa|100.0|2018-05-13T00:00:00|2019-08-28T23:59:59
XO|LT08||HDH|55.5883|-156.5975|-246.0|0.0|0.0|-90.0|Parosci APG Pressure/LDEO_APG_logger|99.7254|0.08|Pa|125.0|2018-05-13T00:00:00|2019-08-28T23:59:59
XO|LT08||HH1|55.5883|-156.5975|-246.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-13T00:00:00|2019-08-28T23:59:59
XO|LT08||HH2|55.5883|-156.5975|-246.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-13T00:00:00|2019-08-28T23:59:59
XO|LT08||HHZ|55.5883|-156.5975|-246.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-13T00:00:00|2019-08-28T23:59:59
XO|LT08|SO|RKO|55.5883|-156.5975|-246.0|0.0|0.0|0.0|LDEO/TRM-3161|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-14T00:10:00|2019-08-15T23:50:00
XO|LT09||EDH|55.1215|-157.1389|-151.0|0.0|0.0|90.0|LDEO HTI90U/LDEO OBS 2011 logger|359.191|2.0|Pa|100.0|2018-05-14T00:00:00|2019-08-19T23:59:59
XO|LT09||HDH|55.1215|-157.1389|-151.0|0.0|0.0|-90.0|Parosci APG Pressure/LDEO_APG_logger|99.7254|0.08|Pa|125.0|2018-05-14T00:00:00|2019-08-19T23:59:59
XO|LT09||HH1|55.1215|-157.1389|-151.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-14T00:00:00|2019-08-19T23:59:59
XO|LT09||HH2|55.1215|-157.1389|-151.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-14T00:00:00|2019-08-19T23:59:59
XO|LT09||HHZ|55.1215|-157.1389|-151.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-14T00:00:00|2019-08-19T23:59:59
XO|LT09||HKO|55.1215|-157.1389|-151.0|0.0|0.0|-90.0|Parosci APG Temperature/LDEO_APG logger|1000.0|10.0|degC|125.0|2018-05-14T00:00:00|2019-08-19T23:59:59
XO|LT09|SO|RKO|55.1215|-157.13892|-151.0|0.0|0.0|0.0|LDEO/TRM-3160|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-16T00:10:00|2019-08-17T23:50:00
XO|LT10||EDH|55.6251|-157.3251|-98.0|0.0|0.0|90.0|LDEO HTI90U/LDEO OBS 2011 logger|359.191|2.0|Pa|100.0|2018-05-13T00:00:00|2019-08-18T23:59:59
XO|LT10||HDH|55.6251|-157.3251|-98.0|0.0|0.0|-90.0|Parosci APG Pressure/LDEO_APG_logger|99.7254|0.08|Pa|125.0|2018-05-13T00:00:00|2019-08-18T23:59:59
XO|LT10||HH1|55.6251|-157.3251|-98.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-13T00:00:00|2019-08-18T23:59:59
XO|LT10||HH2|55.6251|-157.3251|-98.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-13T00:00:00|2019-08-18T23:59:59
XO|LT10||HHZ|55.6251|-157.3251|-98.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-13T00:00:00|2019-08-18T23:59:59
XO|LT10||HKO|55.6251|-157.3251|-98.0|0.0|0.0|-90.0|Parosci APG Temperature/LDEO_APG logger|1000.0|10.0|degC|125.0|2018-05-13T00:00:00|2019-08-18T23:59:59
XO|LT10|SO|RKO|55.6251|-157.3251|-98.0|0.0|0.0|0.0|LDEO/TRM-|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-14T00:10:00|2019-08-16T23:50:00
XO|LT11||EDH|56.1202|-157.3355|-162.0|0.0|0.0|90.0|LDEO HTI90U/LDEO OBS 2011 logger|359.191|2.0|Pa|100.0|2018-05-12T00:00:00|2019-08-28T23:59:59
XO|LT11||HDH|56.1202|-157.3355|-162.0|0.0|0.0|-90.0|Parosci APG Pressure/LDEO_APG_logger|99.7254|0.08|Pa|125.0|2018-05-12T00:00:00|2019-08-28T23:59:59
XO|LT11||HH1|56.1202|-157.3355|-162.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-12T00:00:00|2019-08-28T23:59:59
XO|LT11||HH2|56.1202|-157.3355|-162.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-12T00:00:00|2019-08-28T23:59:59
XO|LT11||HHZ|56.1202|-157.3355|-162.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-12T00:00:00|2019-08-28T23:59:59
XO|LT11||HKO|56.1202|-157.3355|-162.0|0.0|0.0|-90.0|Parosci APG Temperature/LDEO_APG logger|1000.0|10.0|degC|125.0|2018-05-12T00:00:00|2019-08-28T23:59:59
XO|LT11|SO|RKO|56.1202|-157.3355|-162.0|0.0|0.0|0.0|LDEO/TRM-3138|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-13T00:10:00|2019-08-15T23:50:00
XO|LT12||EDH|55.207|-157.778|-83.0|0.0|0.0|90.0|LDEO HTI90U/LDEO OBS 2011 logger|359.191|2.0|Pa|100.0|2018-05-13T00:00:00|2019-08-19T23:59:59
XO|LT12||HDH|55.207|-157.778|-83.0|0.0|0.0|-90.0|Parosci APG Pressure/LDEO_APG_logger|99.7254|0.08|Pa|125.0|2018-05-13T00:00:00|2019-08-19T23:59:59
XO|LT12||HH1|55.207|-157.778|-83.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-13T00:00:00|2019-08-19T23:59:59
XO|LT12||HH2|55.207|-157.778|-83.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-13T00:00:00|2019-08-19T23:59:59
XO|LT12||HHZ|55.207|-157.778|-83.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-13T00:00:00|2019-08-19T23:59:59
XO|LT12||HKO|55.207|-157.778|-83.0|0.0|0.0|-90.0|Parosci APG Temperature/LDEO_APG logger|1000.0|10.0|degC|125.0|2018-05-13T00:00:00|2019-08-19T23:59:59
XO|LT12|SO|RKO|55.207|-157.778|-83.0|0.0|0.0|0.0|LDEO/TRM-3061|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-14T00:10:00|2019-08-17T23:50:00
XO|LT13||EDH|54.8439|-158.3466|-203.0|0.0|0.0|90.0|LDEO HTI90U/LDEO OBS 2011 logger|359.191|2.0|Pa|100.0|2018-05-15T00:00:00|2019-08-22T23:59:59
XO|LT13||HDH|54.8439|-158.3466|-203.0|0.0|0.0|-90.0|Parosci APG Pressure/LDEO_APG_logger|99.7254|0.08|Pa|125.0|2018-05-15T00:00:00|2019-08-22T23:59:59
XO|LT13||HH1|54.8439|-158.3466|-203.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-15T00:00:00|2019-08-22T23:59:59
XO|LT13||HH2|54.8439|-158.3466|-203.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-15T00:00:00|2019-08-22T23:59:59
XO|LT13||HHZ|54.8439|-158.3466|-203.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-15T00:00:00|2019-08-22T23:59:59
XO|LT13||HKO|54.8439|-158.3466|-203.0|0.0|0.0|-90.0|Parosci APG Temperature/LDEO_APG logger|1000.0|10.0|degC|125.0|2018-05-15T00:00:00|2019-08-22T23:59:59
XO|LT13|SO|RKO|54.843925|-158.34662|-203.0|0.0|0.0|0.0|LDEO/TRM-3169|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-16T00:10:00|2019-08-19T23:50:00
XO|LT14||EDH|55.6998|-158.0302|-125.0|0.0|0.0|90.0|LDEO HTI90U/LDEO OBS 2011 logger|359.191|2.0|Pa|100.0|2018-05-12T00:00:00|2019-08-18T23:59:59
XO|LT14||HDH|55.6998|-158.0302|-125.0|0.0|0.0|-90.0|Parosci APG Pressure/LDEO_APG_logger|99.7254|0.08|Pa|125.0|2018-05-12T00:00:00|2019-08-18T23:59:59
XO|LT14||HH1|55.6998|-158.0302|-125.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-12T00:00:00|2019-08-18T23:59:59
XO|LT14||HH2|55.6998|-158.0302|-125.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-12T00:00:00|2019-08-18T23:59:59
XO|LT14||HHZ|55.6998|-158.0302|-125.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-12T00:00:00|2019-08-18T23:59:59
XO|LT14||HKO|55.6998|-158.0302|-125.0|0.0|0.0|-90.0|Parosci APG Temperature/LDEO_APG logger|1000.0|10.0|degC|125.0|2018-05-12T00:00:00|2019-08-18T23:59:59
XO|LT14|SO|RKO|55.69978|-158.03025|-125.0|0.0|0.0|0.0|LDEO/TRM-3158|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-13T00:10:00|2019-08-16T23:50:00
XO|LT15||EDH|55.2002|-158.3598|-167.0|0.0|0.0|90.0|LDEO HTI90U/LDEO OBS 2011 logger|359.191|2.0|Pa|100.0|2018-05-12T00:00:00|2019-08-21T23:59:59
XO|LT15||HDH|55.2002|-158.3598|-167.0|0.0|0.0|-90.0|Parosci APG Pressure/LDEO_APG_logger|99.7254|0.08|Pa|125.0|2018-05-12T00:00:00|2019-08-21T23:59:59
XO|LT15||HH1|55.2002|-158.3598|-167.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-12T00:00:00|2019-08-21T23:59:59
XO|LT15||HH2|55.2002|-158.3598|-167.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-12T00:00:00|2019-08-21T23:59:59
XO|LT15||HHZ|55.2002|-158.3598|-167.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-12T00:00:00|2019-08-21T23:59:59
XO|LT15|SO|RKO|55.20023|-158.3598|-167.0|0.0|0.0|0.0|LDEO/TRM-3163|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-14T00:10:00|2019-08-19T23:50:00
XO|LT16||EDH|55.4916|-158.6013|-125.0|0.0|0.0|90.0|LDEO HTI90U/LDEO OBS 2011 logger|359.191|2.0|Pa|100.0|2018-05-12T00:00:00|2019-08-22T23:59:59
XO|LT16||HDH|55.4916|-158.6013|-125.0|0.0|0.0|-90.0|Parosci APG Pressure/LDEO_APG_logger|99.7254|0.08|Pa|125.0|2018-05-12T00:00:00|2019-08-22T23:59:59
XO|LT16||HH1|55.4916|-158.6013|-125.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-12T00:00:00|2019-08-22T23:59:59
XO|LT16||HH2|55.4916|-158.6013|-125.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-12T00:00:00|2019-08-22T23:59:59
XO|LT16||HHZ|55.4916|-158.6013|-125.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-12T00:00:00|2019-08-22T23:59:59
XO|LT16||HKO|55.4916|-158.6013|-125.0|0.0|0.0|-90.0|Parosci APG Temperature/LDEO_APG logger|1000.0|10.0|degC|125.0|2018-05-12T00:00:00|2019-08-22T23:59:59
XO|LT16|SO|RKO|55.491596|-158.601325|-125.0|0.0|0.0|0.0|LDEO/TRM-3050|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-13T00:10:00|2019-08-20T23:50:00
XO|LT17||EDH|54.5677|-160.2016|-114.0|0.0|0.0|90.0|LDEO HTI90U/LDEO OBS 2011 logger|359.191|2.0|Pa|100.0|2018-05-16T00:00:00|2019-08-23T23:59:59
XO|LT17||HH1|54.5677|-160.2016|-114.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-16T00:00:00|2019-08-23T23:59:59
XO|LT17||HH2|54.5677|-160.2016|-114.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-16T00:00:00|2019-08-23T23:59:59
XO|LT17||HHZ|54.5677|-160.2016|-114.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-16T00:00:00|2019-08-23T23:59:59
XO|LT17|SO|RKO|54.567719|-160.201555|-114.0|0.0|0.0|0.0|LDEO/TRM-3168|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-17T00:10:00|2019-08-20T23:50:00
XO|LT18||EDH|54.74|-160.5814|-115.0|0.0|0.0|90.0|LDEO HTI90U/LDEO OBS 2011 logger|359.191|2.0|Pa|100.0|2018-05-17T00:00:00|2019-08-23T23:59:59
XO|LT18||HH1|54.74|-160.5814|-115.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-17T00:00:00|2019-08-23T23:59:59
XO|LT18||HH2|54.74|-160.5814|-115.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-17T00:00:00|2019-08-23T23:59:59
XO|LT18||HHZ|54.74|-160.5814|-115.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-17T00:00:00|2019-08-23T23:59:59
XO|LT18|SO|RKO|54.74005|-160.5814|-115.0|0.0|0.0|0.0|LDEO/TRM-3084|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-18T00:10:00|2019-08-21T23:50:00
XO|LT20||EDH|54.8002|-161.3746|-150.0|0.0|0.0|90.0|LDEO HTI90U/LDEO OBS 2011 logger|359.191|2.0|Pa|100.0|2018-05-16T00:00:00|2019-08-22T23:59:59
XO|LT20||HDH|54.8002|-161.3746|-150.0|0.0|0.0|-90.0|Parosci APG Pressure/LDEO_APG_logger|99.7254|0.08|Pa|125.0|2018-05-16T00:00:00|2019-08-22T23:59:59
XO|LT20||HH1|54.8002|-161.3746|-150.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-16T00:00:00|2019-08-22T23:59:59
XO|LT20||HH2|54.8002|-161.3746|-150.0|0.0|0.0|0.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-16T00:00:00|2019-08-22T23:59:59
XO|LT20||HHZ|54.8002|-161.3746|-150.0|0.0|0.0|-90.0|Nanometrics Trillium Compact Response/LDEO OBS 201|1.25163E8|0.4|m/s|100.0|2018-05-16T00:00:00|2019-08-22T23:59:59
XO|LT20||HKO|54.8002|-161.3746|-150.0|0.0|0.0|-90.0|Parosci APG Temperature/LDEO_APG logger|1000.0|10.0|degC|125.0|2018-05-16T00:00:00|2019-08-22T23:59:59
XO|LT20|SO|RKO|54.8002|-161.3746|-150.0|0.0|0.0|0.0|LDEO/TRM-3148|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-05-18T00:10:00|2019-08-20T23:50:00
XO|WD46||ACE|55.521393|-149.703732|-4348.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-12T00:00:00|2019-09-11T23:59:59
XO|WD46||HDH|55.521393|-149.703732|-4348.7|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-1007.75|0.4|Pa|100.0|2018-07-12T00:00:00|2019-09-11T23:59:59
XO|WD46||HH1|55.521393|-149.703732|-4348.7|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-12T00:00:00|2019-09-11T23:59:59
XO|WD46||HH2|55.521393|-149.703732|-4348.7|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-12T00:00:00|2019-09-11T23:59:59
XO|WD46||HHZ|55.521393|-149.703732|-4348.7|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-12T00:00:00|2019-09-11T23:59:59
XO|WD46||LCE|55.521393|-149.703732|-4348.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-07-12T00:00:00|2019-09-11T23:59:59
XO|WD46||LCL|55.521393|-149.703732|-4348.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|0.0166667|0.0|s|1.0|2018-07-12T00:00:00|2019-09-11T23:59:59
XO|WD46||LCQ|55.521393|-149.703732|-4348.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-07-12T00:00:00|2019-09-11T23:59:59
XO|WD46||LDH|55.521393|-149.703732|-4348.7|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-772.195|0.04|Pa|1.0|2018-07-12T00:00:00|2019-09-11T23:59:59
XO|WD46||LH1|55.521393|-149.703732|-4348.7|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-12T00:00:00|2019-09-11T23:59:59
XO|WD46||LH2|55.521393|-149.703732|-4348.7|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-12T00:00:00|2019-09-11T23:59:59
XO|WD46||LHZ|55.521393|-149.703732|-4348.7|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-12T00:00:00|2019-09-11T23:59:59
XO|WD46||LOG|55.521393|-149.703732|-4348.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-12T00:00:00|2019-09-11T23:59:59
XO|WD46||OAC|55.521393|-149.703732|-4348.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-12T00:00:00|2019-09-11T23:59:59
XO|WD46||OCF|55.521393|-149.703732|-4348.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-12T00:00:00|2019-09-11T23:59:59
XO|WD46||VCO|55.521393|-149.703732|-4348.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-12T00:00:00|2019-09-11T23:59:59
XO|WD46||VEA|55.521393|-149.703732|-4348.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-12T00:00:00|2019-09-11T23:59:59
XO|WD46||VEC|55.521393|-149.703732|-4348.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-12T00:00:00|2019-09-11T23:59:59
XO|WD46||VEP|55.521393|-149.703732|-4348.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-12T00:00:00|2019-09-11T23:59:59
XO|WD46||VFP|55.521393|-149.703732|-4348.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-12T00:00:00|2019-09-11T23:59:59
XO|WD46||VKI|55.521393|-149.703732|-4348.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-07-12T00:00:00|2019-09-11T23:59:59
XO|WD46||VM0|55.521393|-149.703732|-4348.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-12T00:00:00|2019-09-11T23:59:59
XO|WD46||VM1|55.521393|-149.703732|-4348.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-12T00:00:00|2019-09-11T23:59:59
XO|WD46||VM2|55.521393|-149.703732|-4348.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-12T00:00:00|2019-09-11T23:59:59
XO|WD46||VM3|55.521393|-149.703732|-4348.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-12T00:00:00|2019-09-11T23:59:59
XO|WD46||VM4|55.521393|-149.703732|-4348.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-12T00:00:00|2019-09-11T23:59:59
XO|WD46||VM5|55.521393|-149.703732|-4348.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-12T00:00:00|2019-09-11T23:59:59
XO|WD46||VM6|55.521393|-149.703732|-4348.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-12T00:00:00|2019-09-11T23:59:59
XO|WD46||VMU|55.521393|-149.703732|-4348.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-12T00:00:00|2019-09-11T23:59:59
XO|WD46||VMV|55.521393|-149.703732|-4348.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-12T00:00:00|2019-09-11T23:59:59
XO|WD46||VMW|55.521393|-149.703732|-4348.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-12T00:00:00|2019-09-11T23:59:59
XO|WD46||VMZ|55.521393|-149.703732|-4348.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-12T00:00:00|2019-09-11T23:59:59
XO|WD46||VPB|55.521393|-149.703732|-4348.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-12T00:00:00|2019-09-11T23:59:59
XO|WD46|AN|RKO|55.521393|-149.703732|-4349.0|0.0|0.0|0.0|-S73|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-14T00:20:00|2019-09-07T23:40:00
XO|WD46|T1|RKO|55.521393|-149.703732|-4349.0|0.0|0.0|0.0|-S73|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-13T00:10:00|2019-09-07T23:50:00
XO|WD46|T2|RKO|55.521393|-149.703732|-4349.0|0.0|0.0|0.0|-S73Temperature|1.0|3.125E-4|celsius|8.3333E-4|2018-07-13T00:10:00|2019-09-07T23:50:00
XO|WD47||ACE|54.951352|-150.444793|-3998.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD47||HDH|54.951352|-150.444793|-3998.5|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-1007.75|0.4|Pa|100.0|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD47||HH1|54.951352|-150.444793|-3998.5|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD47||HH2|54.951352|-150.444793|-3998.5|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD47||HHZ|54.951352|-150.444793|-3998.5|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD47||LCE|54.951352|-150.444793|-3998.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD47||LCL|54.951352|-150.444793|-3998.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|0.0166667|0.0|s|1.0|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD47||LCQ|54.951352|-150.444793|-3998.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD47||LDH|54.951352|-150.444793|-3998.5|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-772.195|0.04|Pa|1.0|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD47||LH1|54.951352|-150.444793|-3998.5|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD47||LH2|54.951352|-150.444793|-3998.5|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD47||LHZ|54.951352|-150.444793|-3998.5|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD47||LOG|54.951352|-150.444793|-3998.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD47||OAC|54.951352|-150.444793|-3998.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD47||OCF|54.951352|-150.444793|-3998.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD47||VCO|54.951352|-150.444793|-3998.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD47||VEA|54.951352|-150.444793|-3998.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD47||VEC|54.951352|-150.444793|-3998.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD47||VEP|54.951352|-150.444793|-3998.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD47||VFP|54.951352|-150.444793|-3998.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD47||VKI|54.951352|-150.444793|-3998.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD47||VM0|54.951352|-150.444793|-3998.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD47||VM1|54.951352|-150.444793|-3998.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD47||VM2|54.951352|-150.444793|-3998.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD47||VM3|54.951352|-150.444793|-3998.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD47||VM4|54.951352|-150.444793|-3998.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD47||VM5|54.951352|-150.444793|-3998.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD47||VM6|54.951352|-150.444793|-3998.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD47||VMU|54.951352|-150.444793|-3998.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD47||VMV|54.951352|-150.444793|-3998.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD47||VMW|54.951352|-150.444793|-3998.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD47||VMZ|54.951352|-150.444793|-3998.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD47||VPB|54.951352|-150.444793|-3998.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD47|AN|RKO|54.951352|-150.444792|-3999.0|0.0|0.0|0.0|-S71|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-14T00:20:00|2019-09-07T23:40:00
XO|WD47|T1|RKO|54.951352|-150.444792|-3999.0|0.0|0.0|0.0|-S71|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-14T00:10:00|2019-09-07T23:50:00
XO|WD47|T2|RKO|54.951352|-150.444792|-3999.0|0.0|0.0|0.0|-S71Temperature|1.0|3.125E-4|celsius|8.3333E-4|2018-07-14T00:10:00|2019-09-07T23:50:00
XO|WD48||ACE|56.627365|-151.731343|-1323.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-21T00:00:00|2019-09-04T23:59:59
XO|WD48||HDH|56.627365|-151.731343|-1323.5|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-1007.75|0.4|Pa|100.0|2018-07-21T00:00:00|2019-09-04T23:59:59
XO|WD48||HH1|56.627365|-151.731343|-1323.5|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-21T00:00:00|2019-09-04T23:59:59
XO|WD48||HH2|56.627365|-151.731343|-1323.5|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-21T00:00:00|2019-09-04T23:59:59
XO|WD48||HHZ|56.627365|-151.731343|-1323.5|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-21T00:00:00|2019-09-04T23:59:59
XO|WD48||LCE|56.627365|-151.731343|-1323.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-07-21T00:00:00|2019-09-04T23:59:59
XO|WD48||LCL|56.627365|-151.731343|-1323.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|0.0166667|0.0|s|1.0|2018-07-21T00:00:00|2019-09-04T23:59:59
XO|WD48||LCQ|56.627365|-151.731343|-1323.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-07-21T00:00:00|2019-09-04T23:59:59
XO|WD48||LDH|56.627365|-151.731343|-1323.5|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-772.195|0.04|Pa|1.0|2018-07-21T00:00:00|2019-09-04T23:59:59
XO|WD48||LH1|56.627365|-151.731343|-1323.5|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-21T00:00:00|2019-09-04T23:59:59
XO|WD48||LH2|56.627365|-151.731343|-1323.5|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-21T00:00:00|2019-09-04T23:59:59
XO|WD48||LHZ|56.627365|-151.731343|-1323.5|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-21T00:00:00|2019-09-04T23:59:59
XO|WD48||LOG|56.627365|-151.731343|-1323.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-21T00:00:00|2019-09-04T23:59:59
XO|WD48||OAC|56.627365|-151.731343|-1323.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-21T00:00:00|2019-09-04T23:59:59
XO|WD48||OCF|56.627365|-151.731343|-1323.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-21T00:00:00|2019-09-04T23:59:59
XO|WD48||VCO|56.627365|-151.731343|-1323.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-21T00:00:00|2019-09-04T23:59:59
XO|WD48||VEA|56.627365|-151.731343|-1323.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-21T00:00:00|2019-09-04T23:59:59
XO|WD48||VEC|56.627365|-151.731343|-1323.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-21T00:00:00|2019-09-04T23:59:59
XO|WD48||VEP|56.627365|-151.731343|-1323.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-21T00:00:00|2019-09-04T23:59:59
XO|WD48||VFP|56.627365|-151.731343|-1323.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-21T00:00:00|2019-09-04T23:59:59
XO|WD48||VKI|56.627365|-151.731343|-1323.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-07-21T00:00:00|2019-09-04T23:59:59
XO|WD48||VM0|56.627365|-151.731343|-1323.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-21T00:00:00|2019-09-04T23:59:59
XO|WD48||VM1|56.627365|-151.731343|-1323.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-21T00:00:00|2019-09-04T23:59:59
XO|WD48||VM2|56.627365|-151.731343|-1323.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-21T00:00:00|2019-09-04T23:59:59
XO|WD48||VM3|56.627365|-151.731343|-1323.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-21T00:00:00|2019-09-04T23:59:59
XO|WD48||VM4|56.627365|-151.731343|-1323.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-21T00:00:00|2019-09-04T23:59:59
XO|WD48||VM5|56.627365|-151.731343|-1323.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-21T00:00:00|2019-09-04T23:59:59
XO|WD48||VM6|56.627365|-151.731343|-1323.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-21T00:00:00|2019-09-04T23:59:59
XO|WD48||VMU|56.627365|-151.731343|-1323.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-21T00:00:00|2019-09-04T23:59:59
XO|WD48||VMV|56.627365|-151.731343|-1323.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-21T00:00:00|2019-09-04T23:59:59
XO|WD48||VMW|56.627365|-151.731343|-1323.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-21T00:00:00|2019-09-04T23:59:59
XO|WD48||VMZ|56.627365|-151.731343|-1323.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-21T00:00:00|2019-09-04T23:59:59
XO|WD48||VPB|56.627365|-151.731343|-1323.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-21T00:00:00|2019-09-04T23:59:59
XO|WD48|SO|RKO|56.627365|-151.731343|-1324.0|0.0|0.0|0.0|-S69|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-23T00:10:00|2019-08-25T23:50:00
XO|WD48|T1|RKO|56.627365|-151.731343|-1324.0|0.0|0.0|0.0|-S69|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-22T00:10:00|2019-08-26T23:50:00
XO|WD48|T2|RKO|56.627365|-151.731343|-1324.0|0.0|0.0|0.0|-S69Temperature|1.0|3.125E-4|celsius|8.3333E-4|2018-07-22T00:10:00|2019-08-26T23:50:00
XO|WD49||ACE|54.399083|-151.89947|-4090.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD49||HDH|54.399083|-151.89947|-4090.7|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-1007.75|0.4|Pa|100.0|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD49||HH1|54.399083|-151.89947|-4090.7|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD49||HH2|54.399083|-151.89947|-4090.7|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD49||HHZ|54.399083|-151.89947|-4090.7|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD49||LCE|54.399083|-151.89947|-4090.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD49||LCL|54.399083|-151.89947|-4090.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|0.0166667|0.0|s|1.0|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD49||LCQ|54.399083|-151.89947|-4090.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD49||LDH|54.399083|-151.89947|-4090.7|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-772.195|0.04|Pa|1.0|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD49||LH1|54.399083|-151.89947|-4090.7|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD49||LH2|54.399083|-151.89947|-4090.7|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD49||LHZ|54.399083|-151.89947|-4090.7|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD49||LOG|54.399083|-151.89947|-4090.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD49||OAC|54.399083|-151.89947|-4090.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD49||OCF|54.399083|-151.89947|-4090.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD49||VCO|54.399083|-151.89947|-4090.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD49||VEA|54.399083|-151.89947|-4090.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD49||VEC|54.399083|-151.89947|-4090.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD49||VEP|54.399083|-151.89947|-4090.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD49||VFP|54.399083|-151.89947|-4090.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD49||VKI|54.399083|-151.89947|-4090.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD49||VM0|54.399083|-151.89947|-4090.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD49||VM1|54.399083|-151.89947|-4090.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD49||VM2|54.399083|-151.89947|-4090.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD49||VM3|54.399083|-151.89947|-4090.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD49||VM4|54.399083|-151.89947|-4090.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD49||VM5|54.399083|-151.89947|-4090.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD49||VM6|54.399083|-151.89947|-4090.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD49||VMU|54.399083|-151.89947|-4090.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD49||VMV|54.399083|-151.89947|-4090.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD49||VMW|54.399083|-151.89947|-4090.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD49||VMZ|54.399083|-151.89947|-4090.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD49||VPB|54.399083|-151.89947|-4090.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-13T00:00:00|2019-09-11T23:59:59
XO|WD49|AN|RKO|54.399083|-151.89947|-4091.0|0.0|0.0|0.0|-S38|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-14T00:20:00|2019-09-07T23:40:00
XO|WD49|T1|RKO|54.399083|-151.89947|-4091.0|0.0|0.0|0.0|-S38|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-14T00:10:00|2019-09-06T23:50:00
XO|WD49|T2|RKO|54.399083|-151.89947|-4091.0|0.0|0.0|0.0|-S38Temperature|1.0|3.125E-4|celsius|8.3333E-4|2018-07-14T00:10:00|2019-09-06T23:50:00
XO|WD50||ACE|55.449527|-152.391763|-4986.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WD50||HDH|55.449527|-152.391763|-4986.6|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-1007.75|0.4|Pa|100.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WD50||HH1|55.449527|-152.391763|-4986.6|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WD50||HH2|55.449527|-152.391763|-4986.6|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WD50||HHZ|55.449527|-152.391763|-4986.6|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WD50||LCE|55.449527|-152.391763|-4986.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WD50||LCL|55.449527|-152.391763|-4986.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|0.0166667|0.0|s|1.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WD50||LCQ|55.449527|-152.391763|-4986.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WD50||LDH|55.449527|-152.391763|-4986.6|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-772.195|0.04|Pa|1.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WD50||LH1|55.449527|-152.391763|-4986.6|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WD50||LH2|55.449527|-152.391763|-4986.6|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WD50||LHZ|55.449527|-152.391763|-4986.6|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WD50||LOG|55.449527|-152.391763|-4986.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WD50||OAC|55.449527|-152.391763|-4986.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WD50||OCF|55.449527|-152.391763|-4986.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WD50||VCO|55.449527|-152.391763|-4986.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WD50||VEA|55.449527|-152.391763|-4986.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WD50||VEC|55.449527|-152.391763|-4986.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WD50||VEP|55.449527|-152.391763|-4986.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WD50||VFP|55.449527|-152.391763|-4986.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WD50||VKI|55.449527|-152.391763|-4986.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WD50||VM0|55.449527|-152.391763|-4986.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WD50||VM1|55.449527|-152.391763|-4986.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WD50||VM2|55.449527|-152.391763|-4986.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WD50||VM3|55.449527|-152.391763|-4986.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WD50||VM4|55.449527|-152.391763|-4986.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WD50||VM5|55.449527|-152.391763|-4986.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WD50||VM6|55.449527|-152.391763|-4986.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WD50||VMU|55.449527|-152.391763|-4986.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WD50||VMV|55.449527|-152.391763|-4986.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WD50||VMW|55.449527|-152.391763|-4986.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WD50||VMZ|55.449527|-152.391763|-4986.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WD50||VPB|55.449527|-152.391763|-4986.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WD51||ACE|55.905087|-152.771768|-4361.0|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD51||HDH|55.905087|-152.771768|-4361.0|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-1007.75|0.4|Pa|100.0|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD51||HH1|55.905087|-152.771768|-4361.0|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD51||HH2|55.905087|-152.771768|-4361.0|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD51||HHZ|55.905087|-152.771768|-4361.0|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD51||LCE|55.905087|-152.771768|-4361.0|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD51||LCL|55.905087|-152.771768|-4361.0|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|0.0166667|0.0|s|1.0|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD51||LCQ|55.905087|-152.771768|-4361.0|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD51||LDH|55.905087|-152.771768|-4361.0|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-772.195|0.04|Pa|1.0|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD51||LH1|55.905087|-152.771768|-4361.0|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD51||LH2|55.905087|-152.771768|-4361.0|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD51||LHZ|55.905087|-152.771768|-4361.0|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD51||LOG|55.905087|-152.771768|-4361.0|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD51||OAC|55.905087|-152.771768|-4361.0|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD51||OCF|55.905087|-152.771768|-4361.0|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD51||VCO|55.905087|-152.771768|-4361.0|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD51||VEA|55.905087|-152.771768|-4361.0|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD51||VEC|55.905087|-152.771768|-4361.0|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD51||VEP|55.905087|-152.771768|-4361.0|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD51||VFP|55.905087|-152.771768|-4361.0|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD51||VKI|55.905087|-152.771768|-4361.0|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD51||VM0|55.905087|-152.771768|-4361.0|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD51||VM1|55.905087|-152.771768|-4361.0|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD51||VM2|55.905087|-152.771768|-4361.0|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD51||VM3|55.905087|-152.771768|-4361.0|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD51||VM4|55.905087|-152.771768|-4361.0|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD51||VM5|55.905087|-152.771768|-4361.0|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD51||VM6|55.905087|-152.771768|-4361.0|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD51||VMU|55.905087|-152.771768|-4361.0|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD51||VMV|55.905087|-152.771768|-4361.0|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD51||VMW|55.905087|-152.771768|-4361.0|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD51||VMZ|55.905087|-152.771768|-4361.0|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD51||VPB|55.905087|-152.771768|-4361.0|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD51|T1|RKO|55.905087|-152.771768|-4361.0|0.0|0.0|0.0|-S70|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-21T00:10:00|2019-08-26T23:50:00
XO|WD52||ACE|54.046622|-159.346215|-2563.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-18T00:00:00|2019-09-03T23:59:59
XO|WD52||HDH|54.046622|-159.346215|-2563.6|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-1007.75|0.4|Pa|100.0|2018-07-18T00:00:00|2019-09-03T23:59:59
XO|WD52||HH1|54.046622|-159.346215|-2563.6|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-18T00:00:00|2019-09-03T23:59:59
XO|WD52||HH2|54.046622|-159.346215|-2563.6|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-18T00:00:00|2019-09-03T23:59:59
XO|WD52||HHZ|54.046622|-159.346215|-2563.6|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-18T00:00:00|2019-09-03T23:59:59
XO|WD52||LCE|54.046622|-159.346215|-2563.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-07-18T00:00:00|2019-09-03T23:59:59
XO|WD52||LCL|54.046622|-159.346215|-2563.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|0.0166667|0.0|s|1.0|2018-07-18T00:00:00|2019-09-03T23:59:59
XO|WD52||LCQ|54.046622|-159.346215|-2563.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-07-18T00:00:00|2019-09-03T23:59:59
XO|WD52||LDH|54.046622|-159.346215|-2563.6|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-772.195|0.04|Pa|1.0|2018-07-18T00:00:00|2019-09-03T23:59:59
XO|WD52||LH1|54.046622|-159.346215|-2563.6|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-18T00:00:00|2019-09-03T23:59:59
XO|WD52||LH2|54.046622|-159.346215|-2563.6|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-18T00:00:00|2019-09-03T23:59:59
XO|WD52||LHZ|54.046622|-159.346215|-2563.6|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-18T00:00:00|2019-09-03T23:59:59
XO|WD52||LOG|54.046622|-159.346215|-2563.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-18T00:00:00|2019-09-03T23:59:59
XO|WD52||OAC|54.046622|-159.346215|-2563.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-18T00:00:00|2019-09-03T23:59:59
XO|WD52||OCF|54.046622|-159.346215|-2563.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-18T00:00:00|2019-09-03T23:59:59
XO|WD52||VCO|54.046622|-159.346215|-2563.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-18T00:00:00|2019-09-03T23:59:59
XO|WD52||VEA|54.046622|-159.346215|-2563.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-18T00:00:00|2019-09-03T23:59:59
XO|WD52||VEC|54.046622|-159.346215|-2563.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-18T00:00:00|2019-09-03T23:59:59
XO|WD52||VEP|54.046622|-159.346215|-2563.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-18T00:00:00|2019-09-03T23:59:59
XO|WD52||VFP|54.046622|-159.346215|-2563.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-18T00:00:00|2019-09-03T23:59:59
XO|WD52||VKI|54.046622|-159.346215|-2563.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-07-18T00:00:00|2019-09-03T23:59:59
XO|WD52||VM0|54.046622|-159.346215|-2563.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-09-03T23:59:59
XO|WD52||VM1|54.046622|-159.346215|-2563.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-09-03T23:59:59
XO|WD52||VM2|54.046622|-159.346215|-2563.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-09-03T23:59:59
XO|WD52||VM3|54.046622|-159.346215|-2563.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-09-03T23:59:59
XO|WD52||VM4|54.046622|-159.346215|-2563.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-09-03T23:59:59
XO|WD52||VM5|54.046622|-159.346215|-2563.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-09-03T23:59:59
XO|WD52||VM6|54.046622|-159.346215|-2563.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-09-03T23:59:59
XO|WD52||VMU|54.046622|-159.346215|-2563.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-09-03T23:59:59
XO|WD52||VMV|54.046622|-159.346215|-2563.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-09-03T23:59:59
XO|WD52||VMW|54.046622|-159.346215|-2563.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-09-03T23:59:59
XO|WD52||VMZ|54.046622|-159.346215|-2563.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-09-03T23:59:59
XO|WD52||VPB|54.046622|-159.346215|-2563.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-18T00:00:00|2019-09-03T23:59:59
XO|WD52|SO|RKO|54.046622|-159.346215|-2564.0|0.0|0.0|0.0|-S61|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-19T00:10:00|2019-08-29T23:50:00
XO|WD52|T1|RKO|54.046622|-159.346215|-2564.0|0.0|0.0|0.0|-S61|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-19T00:10:00|2019-08-28T23:50:00
XO|WD52|T2|RKO|54.046622|-159.346215|-2564.0|0.0|0.0|0.0|-S61Temperature|1.0|3.125E-4|celsius|8.3333E-4|2018-07-19T00:10:00|2019-08-28T23:50:00
XO|WD53||ACE|53.779448|-153.422908|-4645.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-13T00:00:00|2019-09-10T23:59:59
XO|WD53||HDH|53.779448|-153.422908|-4645.7|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-1007.75|0.4|Pa|100.0|2018-07-13T00:00:00|2019-09-10T23:59:59
XO|WD53||HH1|53.779448|-153.422908|-4645.7|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-13T00:00:00|2019-09-10T23:59:59
XO|WD53||HH2|53.779448|-153.422908|-4645.7|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-13T00:00:00|2019-09-10T23:59:59
XO|WD53||HHZ|53.779448|-153.422908|-4645.7|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-13T00:00:00|2019-09-10T23:59:59
XO|WD53||LCE|53.779448|-153.422908|-4645.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-07-13T00:00:00|2019-09-10T23:59:59
XO|WD53||LCL|53.779448|-153.422908|-4645.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|0.0166667|0.0|s|1.0|2018-07-13T00:00:00|2019-09-10T23:59:59
XO|WD53||LCQ|53.779448|-153.422908|-4645.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-07-13T00:00:00|2019-09-10T23:59:59
XO|WD53||LDH|53.779448|-153.422908|-4645.7|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-772.195|0.04|Pa|1.0|2018-07-13T00:00:00|2019-09-10T23:59:59
XO|WD53||LH1|53.779448|-153.422908|-4645.7|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-13T00:00:00|2019-09-10T23:59:59
XO|WD53||LH2|53.779448|-153.422908|-4645.7|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-13T00:00:00|2019-09-10T23:59:59
XO|WD53||LHZ|53.779448|-153.422908|-4645.7|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-13T00:00:00|2019-09-10T23:59:59
XO|WD53||LOG|53.779448|-153.422908|-4645.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-13T00:00:00|2019-09-10T23:59:59
XO|WD53||OAC|53.779448|-153.422908|-4645.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-13T00:00:00|2019-09-10T23:59:59
XO|WD53||OCF|53.779448|-153.422908|-4645.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-13T00:00:00|2019-09-10T23:59:59
XO|WD53||VCO|53.779448|-153.422908|-4645.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-13T00:00:00|2019-09-10T23:59:59
XO|WD53||VEA|53.779448|-153.422908|-4645.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-13T00:00:00|2019-09-10T23:59:59
XO|WD53||VEC|53.779448|-153.422908|-4645.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-13T00:00:00|2019-09-10T23:59:59
XO|WD53||VEP|53.779448|-153.422908|-4645.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-13T00:00:00|2019-09-10T23:59:59
XO|WD53||VFP|53.779448|-153.422908|-4645.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-13T00:00:00|2019-09-10T23:59:59
XO|WD53||VKI|53.779448|-153.422908|-4645.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-07-13T00:00:00|2019-09-10T23:59:59
XO|WD53||VM0|53.779448|-153.422908|-4645.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-13T00:00:00|2019-09-10T23:59:59
XO|WD53||VM1|53.779448|-153.422908|-4645.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-13T00:00:00|2019-09-10T23:59:59
XO|WD53||VM2|53.779448|-153.422908|-4645.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-13T00:00:00|2019-09-10T23:59:59
XO|WD53||VM3|53.779448|-153.422908|-4645.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-13T00:00:00|2019-09-10T23:59:59
XO|WD53||VM4|53.779448|-153.422908|-4645.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-13T00:00:00|2019-09-10T23:59:59
XO|WD53||VM5|53.779448|-153.422908|-4645.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-13T00:00:00|2019-09-10T23:59:59
XO|WD53||VM6|53.779448|-153.422908|-4645.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-13T00:00:00|2019-09-10T23:59:59
XO|WD53||VMU|53.779448|-153.422908|-4645.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-13T00:00:00|2019-09-10T23:59:59
XO|WD53||VMV|53.779448|-153.422908|-4645.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-13T00:00:00|2019-09-10T23:59:59
XO|WD53||VMW|53.779448|-153.422908|-4645.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-13T00:00:00|2019-09-10T23:59:59
XO|WD53||VMZ|53.779448|-153.422908|-4645.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-13T00:00:00|2019-09-10T23:59:59
XO|WD53||VPB|53.779448|-153.422908|-4645.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-13T00:00:00|2019-09-10T23:59:59
XO|WD53|AN|RKO|53.779448|-153.422908|-4646.0|0.0|0.0|0.0|-S59|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-15T00:20:00|2019-09-06T23:40:00
XO|WD53|T1|RKO|53.779448|-153.422908|-4646.0|0.0|0.0|0.0|-S59|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-15T00:10:00|2019-09-06T23:50:00
XO|WD53|T2|RKO|53.779448|-153.422908|-4646.0|0.0|0.0|0.0|-S59Temperature|1.0|3.125E-4|celsius|8.3333E-4|2018-07-15T00:10:00|2019-09-06T23:50:00
XO|WD54||ACE|56.331433|-149.066665|-4520.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-22T00:00:00|2019-09-11T23:59:59
XO|WD54||HDH|56.331433|-149.066665|-4520.4|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-1007.75|0.4|Pa|100.0|2018-07-22T00:00:00|2019-09-11T23:59:59
XO|WD54||HH1|56.331433|-149.066665|-4520.4|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-22T00:00:00|2019-09-11T23:59:59
XO|WD54||HH2|56.331433|-149.066665|-4520.4|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-22T00:00:00|2019-09-11T23:59:59
XO|WD54||HHZ|56.331433|-149.066665|-4520.4|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-22T00:00:00|2019-09-11T23:59:59
XO|WD54||LCE|56.331433|-149.066665|-4520.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-07-22T00:00:00|2019-09-11T23:59:59
XO|WD54||LCL|56.331433|-149.066665|-4520.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|0.0166667|0.0|s|1.0|2018-07-22T00:00:00|2019-09-11T23:59:59
XO|WD54||LCQ|56.331433|-149.066665|-4520.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-07-22T00:00:00|2019-09-11T23:59:59
XO|WD54||LDH|56.331433|-149.066665|-4520.4|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-772.195|0.04|Pa|1.0|2018-07-22T00:00:00|2019-09-11T23:59:59
XO|WD54||LH1|56.331433|-149.066665|-4520.4|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-22T00:00:00|2019-09-11T23:59:59
XO|WD54||LH2|56.331433|-149.066665|-4520.4|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-22T00:00:00|2019-09-11T23:59:59
XO|WD54||LHZ|56.331433|-149.066665|-4520.4|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-22T00:00:00|2019-09-11T23:59:59
XO|WD54||LOG|56.331433|-149.066665|-4520.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-22T00:00:00|2019-09-11T23:59:59
XO|WD54||OAC|56.331433|-149.066665|-4520.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-22T00:00:00|2019-09-11T23:59:59
XO|WD54||OCF|56.331433|-149.066665|-4520.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-22T00:00:00|2019-09-11T23:59:59
XO|WD54||VCO|56.331433|-149.066665|-4520.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-22T00:00:00|2019-09-11T23:59:59
XO|WD54||VEA|56.331433|-149.066665|-4520.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-22T00:00:00|2019-09-11T23:59:59
XO|WD54||VEC|56.331433|-149.066665|-4520.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-22T00:00:00|2019-09-11T23:59:59
XO|WD54||VEP|56.331433|-149.066665|-4520.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-22T00:00:00|2019-09-11T23:59:59
XO|WD54||VFP|56.331433|-149.066665|-4520.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-22T00:00:00|2019-09-11T23:59:59
XO|WD54||VKI|56.331433|-149.066665|-4520.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-07-22T00:00:00|2019-09-11T23:59:59
XO|WD54||VM0|56.331433|-149.066665|-4520.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-22T00:00:00|2019-09-11T23:59:59
XO|WD54||VM1|56.331433|-149.066665|-4520.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-22T00:00:00|2019-09-11T23:59:59
XO|WD54||VM2|56.331433|-149.066665|-4520.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-22T00:00:00|2019-09-11T23:59:59
XO|WD54||VM3|56.331433|-149.066665|-4520.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-22T00:00:00|2019-09-11T23:59:59
XO|WD54||VM4|56.331433|-149.066665|-4520.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-22T00:00:00|2019-09-11T23:59:59
XO|WD54||VM5|56.331433|-149.066665|-4520.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-22T00:00:00|2019-09-11T23:59:59
XO|WD54||VM6|56.331433|-149.066665|-4520.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-22T00:00:00|2019-09-11T23:59:59
XO|WD54||VMU|56.331433|-149.066665|-4520.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-22T00:00:00|2019-09-11T23:59:59
XO|WD54||VMV|56.331433|-149.066665|-4520.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-22T00:00:00|2019-09-11T23:59:59
XO|WD54||VMW|56.331433|-149.066665|-4520.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-22T00:00:00|2019-09-11T23:59:59
XO|WD54||VMZ|56.331433|-149.066665|-4520.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-22T00:00:00|2019-09-11T23:59:59
XO|WD54||VPB|56.331433|-149.066665|-4520.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-22T00:00:00|2019-09-11T23:59:59
XO|WD54|AN|RKO|56.331433|-149.066665|-4520.0|0.0|0.0|0.0|-S30|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-23T00:20:00|2019-09-08T23:40:00
XO|WD54|T1|RKO|56.331433|-149.066665|-4520.0|0.0|0.0|0.0|-S30|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-23T00:10:00|2019-09-08T23:50:00
XO|WD54|T2|RKO|56.331433|-149.066665|-4520.0|0.0|0.0|0.0|-S30Temperature|1.0|3.125E-4|celsius|8.3333E-4|2018-07-23T00:10:00|2019-09-08T23:50:00
XO|WD55||ACE|55.761625|-153.662817|-1283.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD55||HDH|55.761625|-153.662817|-1283.5|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-1007.75|0.4|Pa|100.0|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD55||HH1|55.761625|-153.662817|-1283.5|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD55||HH2|55.761625|-153.662817|-1283.5|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD55||HHZ|55.761625|-153.662817|-1283.5|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD55||LCE|55.761625|-153.662817|-1283.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD55||LCL|55.761625|-153.662817|-1283.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|0.0166667|0.0|s|1.0|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD55||LCQ|55.761625|-153.662817|-1283.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD55||LDH|55.761625|-153.662817|-1283.5|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-772.195|0.04|Pa|1.0|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD55||LH1|55.761625|-153.662817|-1283.5|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD55||LH2|55.761625|-153.662817|-1283.5|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD55||LHZ|55.761625|-153.662817|-1283.5|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD55||LOG|55.761625|-153.662817|-1283.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD55||OAC|55.761625|-153.662817|-1283.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD55||OCF|55.761625|-153.662817|-1283.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD55||VCO|55.761625|-153.662817|-1283.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD55||VEA|55.761625|-153.662817|-1283.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD55||VEC|55.761625|-153.662817|-1283.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD55||VEP|55.761625|-153.662817|-1283.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD55||VFP|55.761625|-153.662817|-1283.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD55||VKI|55.761625|-153.662817|-1283.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD55||VM0|55.761625|-153.662817|-1283.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD55||VM1|55.761625|-153.662817|-1283.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD55||VM2|55.761625|-153.662817|-1283.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD55||VM3|55.761625|-153.662817|-1283.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD55||VM4|55.761625|-153.662817|-1283.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD55||VM5|55.761625|-153.662817|-1283.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD55||VM6|55.761625|-153.662817|-1283.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD55||VMU|55.761625|-153.662817|-1283.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD55||VMV|55.761625|-153.662817|-1283.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD55||VMW|55.761625|-153.662817|-1283.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD55||VMZ|55.761625|-153.662817|-1283.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD55||VPB|55.761625|-153.662817|-1283.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-20T00:00:00|2019-09-01T23:59:59
XO|WD55|SO|RKO|55.761625|-153.662817|-1284.0|0.0|0.0|0.0|-S65|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-21T00:10:00|2019-08-26T23:50:00
XO|WD55|T1|RKO|55.761625|-153.662817|-1284.0|0.0|0.0|0.0|-S65|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-21T00:10:00|2019-08-26T23:50:00
XO|WD55|T2|RKO|55.761625|-153.662817|-1284.0|0.0|0.0|0.0|-S65Temperature|1.0|3.125E-4|celsius|8.3333E-4|2018-07-21T00:10:00|2019-08-26T23:50:00
XO|WD56||ACE|55.322267|-154.047078|-4059.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-19T00:00:00|2019-08-30T23:59:59
XO|WD56||HDH|55.322267|-154.047078|-4059.9|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-1007.75|0.4|Pa|100.0|2018-07-19T00:00:00|2019-08-30T23:59:59
XO|WD56||HH1|55.322267|-154.047078|-4059.9|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-19T00:00:00|2019-08-30T23:59:59
XO|WD56||HH2|55.322267|-154.047078|-4059.9|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-19T00:00:00|2019-08-30T23:59:59
XO|WD56||HHZ|55.322267|-154.047078|-4059.9|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-19T00:00:00|2019-08-30T23:59:59
XO|WD56||LCE|55.322267|-154.047078|-4059.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-07-19T00:00:00|2019-08-30T23:59:59
XO|WD56||LCL|55.322267|-154.047078|-4059.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|0.0166667|0.0|s|1.0|2018-07-19T00:00:00|2019-08-30T23:59:59
XO|WD56||LCQ|55.322267|-154.047078|-4059.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-07-19T00:00:00|2019-08-30T23:59:59
XO|WD56||LDH|55.322267|-154.047078|-4059.9|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-772.195|0.04|Pa|1.0|2018-07-19T00:00:00|2019-08-30T23:59:59
XO|WD56||LH1|55.322267|-154.047078|-4059.9|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-19T00:00:00|2019-08-30T23:59:59
XO|WD56||LH2|55.322267|-154.047078|-4059.9|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-19T00:00:00|2019-08-30T23:59:59
XO|WD56||LHZ|55.322267|-154.047078|-4059.9|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-19T00:00:00|2019-08-30T23:59:59
XO|WD56||LOG|55.322267|-154.047078|-4059.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-19T00:00:00|2019-08-30T23:59:59
XO|WD56||OAC|55.322267|-154.047078|-4059.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-19T00:00:00|2019-08-30T23:59:59
XO|WD56||OCF|55.322267|-154.047078|-4059.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-19T00:00:00|2019-08-30T23:59:59
XO|WD56||VCO|55.322267|-154.047078|-4059.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-19T00:00:00|2019-08-30T23:59:59
XO|WD56||VEA|55.322267|-154.047078|-4059.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-19T00:00:00|2019-08-30T23:59:59
XO|WD56||VEC|55.322267|-154.047078|-4059.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-19T00:00:00|2019-08-30T23:59:59
XO|WD56||VEP|55.322267|-154.047078|-4059.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-19T00:00:00|2019-08-30T23:59:59
XO|WD56||VFP|55.322267|-154.047078|-4059.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-19T00:00:00|2019-08-30T23:59:59
XO|WD56||VKI|55.322267|-154.047078|-4059.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-07-19T00:00:00|2019-08-30T23:59:59
XO|WD56||VM0|55.322267|-154.047078|-4059.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-19T00:00:00|2019-08-30T23:59:59
XO|WD56||VM1|55.322267|-154.047078|-4059.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-19T00:00:00|2019-08-30T23:59:59
XO|WD56||VM2|55.322267|-154.047078|-4059.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-19T00:00:00|2019-08-30T23:59:59
XO|WD56||VM3|55.322267|-154.047078|-4059.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-19T00:00:00|2019-08-30T23:59:59
XO|WD56||VM4|55.322267|-154.047078|-4059.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-19T00:00:00|2019-08-30T23:59:59
XO|WD56||VM5|55.322267|-154.047078|-4059.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-19T00:00:00|2019-08-30T23:59:59
XO|WD56||VM6|55.322267|-154.047078|-4059.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-19T00:00:00|2019-08-30T23:59:59
XO|WD56||VMU|55.322267|-154.047078|-4059.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-19T00:00:00|2019-08-30T23:59:59
XO|WD56||VMV|55.322267|-154.047078|-4059.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-19T00:00:00|2019-08-30T23:59:59
XO|WD56||VMW|55.322267|-154.047078|-4059.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-19T00:00:00|2019-08-30T23:59:59
XO|WD56||VMZ|55.322267|-154.047078|-4059.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-19T00:00:00|2019-08-30T23:59:59
XO|WD56||VPB|55.322267|-154.047078|-4059.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-19T00:00:00|2019-08-30T23:59:59
XO|WD56|AN|RKO|55.322267|-154.047078|-4060.0|0.0|0.0|0.0|-S48|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-21T00:20:00|2019-08-27T23:40:00
XO|WD57||ACE|54.736387|-154.434305|-5053.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-19T00:00:00|2019-08-31T23:59:59
XO|WD57||HDH|54.736387|-154.434305|-5053.3|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-1007.75|0.4|Pa|100.0|2018-07-19T00:00:00|2019-08-31T23:59:59
XO|WD57||HH1|54.736387|-154.434305|-5053.3|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-19T00:00:00|2019-08-31T23:59:59
XO|WD57||HH2|54.736387|-154.434305|-5053.3|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-19T00:00:00|2019-08-31T23:59:59
XO|WD57||HHZ|54.736387|-154.434305|-5053.3|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-19T00:00:00|2019-08-31T23:59:59
XO|WD57||LCE|54.736387|-154.434305|-5053.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-07-19T00:00:00|2019-08-31T23:59:59
XO|WD57||LCL|54.736387|-154.434305|-5053.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|0.0166667|0.0|s|1.0|2018-07-19T00:00:00|2019-08-31T23:59:59
XO|WD57||LCQ|54.736387|-154.434305|-5053.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-07-19T00:00:00|2019-08-31T23:59:59
XO|WD57||LDH|54.736387|-154.434305|-5053.3|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-772.195|0.04|Pa|1.0|2018-07-19T00:00:00|2019-08-31T23:59:59
XO|WD57||LH1|54.736387|-154.434305|-5053.3|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-19T00:00:00|2019-08-31T23:59:59
XO|WD57||LH2|54.736387|-154.434305|-5053.3|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-19T00:00:00|2019-08-31T23:59:59
XO|WD57||LHZ|54.736387|-154.434305|-5053.3|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-19T00:00:00|2019-08-31T23:59:59
XO|WD57||LOG|54.736387|-154.434305|-5053.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-19T00:00:00|2019-08-31T23:59:59
XO|WD57||OAC|54.736387|-154.434305|-5053.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-19T00:00:00|2019-08-31T23:59:59
XO|WD57||OCF|54.736387|-154.434305|-5053.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-19T00:00:00|2019-08-31T23:59:59
XO|WD57||VCO|54.736387|-154.434305|-5053.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-19T00:00:00|2019-08-31T23:59:59
XO|WD57||VEA|54.736387|-154.434305|-5053.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-19T00:00:00|2019-08-31T23:59:59
XO|WD57||VEC|54.736387|-154.434305|-5053.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-19T00:00:00|2019-08-31T23:59:59
XO|WD57||VEP|54.736387|-154.434305|-5053.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-19T00:00:00|2019-08-31T23:59:59
XO|WD57||VFP|54.736387|-154.434305|-5053.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-19T00:00:00|2019-08-31T23:59:59
XO|WD57||VKI|54.736387|-154.434305|-5053.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-07-19T00:00:00|2019-08-31T23:59:59
XO|WD57||VM0|54.736387|-154.434305|-5053.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-19T00:00:00|2019-08-31T23:59:59
XO|WD57||VM1|54.736387|-154.434305|-5053.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-19T00:00:00|2019-08-31T23:59:59
XO|WD57||VM2|54.736387|-154.434305|-5053.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-19T00:00:00|2019-08-31T23:59:59
XO|WD57||VM3|54.736387|-154.434305|-5053.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-19T00:00:00|2019-08-31T23:59:59
XO|WD57||VM4|54.736387|-154.434305|-5053.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-19T00:00:00|2019-08-31T23:59:59
XO|WD57||VM5|54.736387|-154.434305|-5053.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-19T00:00:00|2019-08-31T23:59:59
XO|WD57||VM6|54.736387|-154.434305|-5053.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-19T00:00:00|2019-08-31T23:59:59
XO|WD57||VMU|54.736387|-154.434305|-5053.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-19T00:00:00|2019-08-31T23:59:59
XO|WD57||VMV|54.736387|-154.434305|-5053.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-19T00:00:00|2019-08-31T23:59:59
XO|WD57||VMW|54.736387|-154.434305|-5053.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-19T00:00:00|2019-08-31T23:59:59
XO|WD57||VMZ|54.736387|-154.434305|-5053.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-19T00:00:00|2019-08-31T23:59:59
XO|WD57||VPB|54.736387|-154.434305|-5053.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-19T00:00:00|2019-08-31T23:59:59
XO|WD57|T1|RKO|54.736387|-154.434305|-5053.0|0.0|0.0|0.0|-S19|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-20T00:10:00|2019-08-27T23:50:00
XO|WD58||ACE|53.906227|-155.035345|-4493.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-14T00:00:00|2019-09-09T23:59:59
XO|WD58||HDH|53.906227|-155.035345|-4493.3|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-1007.75|0.4|Pa|100.0|2018-07-14T00:00:00|2019-09-09T23:59:59
XO|WD58||HH1|53.906227|-155.035345|-4493.3|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-14T00:00:00|2019-09-09T23:59:59
XO|WD58||HH2|53.906227|-155.035345|-4493.3|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-14T00:00:00|2019-09-09T23:59:59
XO|WD58||HHZ|53.906227|-155.035345|-4493.3|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-14T00:00:00|2019-09-09T23:59:59
XO|WD58||LCE|53.906227|-155.035345|-4493.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-07-14T00:00:00|2019-09-09T23:59:59
XO|WD58||LCL|53.906227|-155.035345|-4493.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|0.0166667|0.0|s|1.0|2018-07-14T00:00:00|2019-09-09T23:59:59
XO|WD58||LCQ|53.906227|-155.035345|-4493.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-07-14T00:00:00|2019-09-09T23:59:59
XO|WD58||LDH|53.906227|-155.035345|-4493.3|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-772.195|0.04|Pa|1.0|2018-07-14T00:00:00|2019-09-09T23:59:59
XO|WD58||LH1|53.906227|-155.035345|-4493.3|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-14T00:00:00|2019-09-09T23:59:59
XO|WD58||LH2|53.906227|-155.035345|-4493.3|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-14T00:00:00|2019-09-09T23:59:59
XO|WD58||LHZ|53.906227|-155.035345|-4493.3|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-14T00:00:00|2019-09-09T23:59:59
XO|WD58||LOG|53.906227|-155.035345|-4493.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-14T00:00:00|2019-09-09T23:59:59
XO|WD58||OAC|53.906227|-155.035345|-4493.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-14T00:00:00|2019-09-09T23:59:59
XO|WD58||OCF|53.906227|-155.035345|-4493.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-14T00:00:00|2019-09-09T23:59:59
XO|WD58||VCO|53.906227|-155.035345|-4493.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-14T00:00:00|2019-09-09T23:59:59
XO|WD58||VEA|53.906227|-155.035345|-4493.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-14T00:00:00|2019-09-09T23:59:59
XO|WD58||VEC|53.906227|-155.035345|-4493.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-14T00:00:00|2019-09-09T23:59:59
XO|WD58||VEP|53.906227|-155.035345|-4493.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-14T00:00:00|2019-09-09T23:59:59
XO|WD58||VFP|53.906227|-155.035345|-4493.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-14T00:00:00|2019-09-09T23:59:59
XO|WD58||VKI|53.906227|-155.035345|-4493.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-07-14T00:00:00|2019-09-09T23:59:59
XO|WD58||VM0|53.906227|-155.035345|-4493.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-14T00:00:00|2019-09-09T23:59:59
XO|WD58||VM1|53.906227|-155.035345|-4493.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-14T00:00:00|2019-09-09T23:59:59
XO|WD58||VM2|53.906227|-155.035345|-4493.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-14T00:00:00|2019-09-09T23:59:59
XO|WD58||VM3|53.906227|-155.035345|-4493.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-14T00:00:00|2019-09-09T23:59:59
XO|WD58||VM4|53.906227|-155.035345|-4493.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-14T00:00:00|2019-09-09T23:59:59
XO|WD58||VM5|53.906227|-155.035345|-4493.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-14T00:00:00|2019-09-09T23:59:59
XO|WD58||VM6|53.906227|-155.035345|-4493.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-14T00:00:00|2019-09-09T23:59:59
XO|WD58||VMU|53.906227|-155.035345|-4493.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-14T00:00:00|2019-09-09T23:59:59
XO|WD58||VMV|53.906227|-155.035345|-4493.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-14T00:00:00|2019-09-09T23:59:59
XO|WD58||VMW|53.906227|-155.035345|-4493.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-14T00:00:00|2019-09-09T23:59:59
XO|WD58||VMZ|53.906227|-155.035345|-4493.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-14T00:00:00|2019-09-09T23:59:59
XO|WD58||VPB|53.906227|-155.035345|-4493.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-14T00:00:00|2019-09-09T23:59:59
XO|WD58|AN|RKO|53.906227|-155.035345|-4493.0|0.0|0.0|0.0|-S01|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-15T00:20:00|2019-09-06T23:40:00
XO|WD59||ACE|53.383713|-155.799387|-4550.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-14T00:00:00|2019-09-10T23:59:59
XO|WD59||HDH|53.383713|-155.799387|-4550.3|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-1007.75|0.4|Pa|100.0|2018-07-14T00:00:00|2019-09-10T23:59:59
XO|WD59||HH1|53.383713|-155.799387|-4550.3|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-14T00:00:00|2019-09-10T23:59:59
XO|WD59||HH2|53.383713|-155.799387|-4550.3|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-14T00:00:00|2019-09-10T23:59:59
XO|WD59||HHZ|53.383713|-155.799387|-4550.3|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-14T00:00:00|2019-09-10T23:59:59
XO|WD59||LCE|53.383713|-155.799387|-4550.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-07-14T00:00:00|2019-09-10T23:59:59
XO|WD59||LCL|53.383713|-155.799387|-4550.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|0.0166667|0.0|s|1.0|2018-07-14T00:00:00|2019-09-10T23:59:59
XO|WD59||LCQ|53.383713|-155.799387|-4550.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-07-14T00:00:00|2019-09-10T23:59:59
XO|WD59||LDH|53.383713|-155.799387|-4550.3|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-772.195|0.04|Pa|1.0|2018-07-14T00:00:00|2019-09-10T23:59:59
XO|WD59||LH1|53.383713|-155.799387|-4550.3|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-14T00:00:00|2019-09-10T23:59:59
XO|WD59||LH2|53.383713|-155.799387|-4550.3|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-14T00:00:00|2019-09-10T23:59:59
XO|WD59||LHZ|53.383713|-155.799387|-4550.3|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-14T00:00:00|2019-09-10T23:59:59
XO|WD59||LOG|53.383713|-155.799387|-4550.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-14T00:00:00|2019-09-10T23:59:59
XO|WD59||OAC|53.383713|-155.799387|-4550.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-14T00:00:00|2019-09-10T23:59:59
XO|WD59||OCF|53.383713|-155.799387|-4550.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-14T00:00:00|2019-09-10T23:59:59
XO|WD59||VCO|53.383713|-155.799387|-4550.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-14T00:00:00|2019-09-10T23:59:59
XO|WD59||VEA|53.383713|-155.799387|-4550.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-14T00:00:00|2019-09-10T23:59:59
XO|WD59||VEC|53.383713|-155.799387|-4550.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-14T00:00:00|2019-09-10T23:59:59
XO|WD59||VEP|53.383713|-155.799387|-4550.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-14T00:00:00|2019-09-10T23:59:59
XO|WD59||VFP|53.383713|-155.799387|-4550.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-14T00:00:00|2019-09-10T23:59:59
XO|WD59||VKI|53.383713|-155.799387|-4550.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-07-14T00:00:00|2019-09-10T23:59:59
XO|WD59||VM0|53.383713|-155.799387|-4550.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-14T00:00:00|2019-09-10T23:59:59
XO|WD59||VM1|53.383713|-155.799387|-4550.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-14T00:00:00|2019-09-10T23:59:59
XO|WD59||VM2|53.383713|-155.799387|-4550.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-14T00:00:00|2019-09-10T23:59:59
XO|WD59||VM3|53.383713|-155.799387|-4550.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-14T00:00:00|2019-09-10T23:59:59
XO|WD59||VM4|53.383713|-155.799387|-4550.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-14T00:00:00|2019-09-10T23:59:59
XO|WD59||VM5|53.383713|-155.799387|-4550.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-14T00:00:00|2019-09-10T23:59:59
XO|WD59||VM6|53.383713|-155.799387|-4550.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-14T00:00:00|2019-09-10T23:59:59
XO|WD59||VMU|53.383713|-155.799387|-4550.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-14T00:00:00|2019-09-10T23:59:59
XO|WD59||VMV|53.383713|-155.799387|-4550.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-14T00:00:00|2019-09-10T23:59:59
XO|WD59||VMW|53.383713|-155.799387|-4550.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-14T00:00:00|2019-09-10T23:59:59
XO|WD59||VMZ|53.383713|-155.799387|-4550.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-14T00:00:00|2019-09-10T23:59:59
XO|WD59||VPB|53.383713|-155.799387|-4550.3|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-14T00:00:00|2019-09-10T23:59:59
XO|WD59|AN|RKO|53.383713|-155.799387|-4550.0|0.0|0.0|0.0|-S23|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-15T00:20:00|2019-09-06T23:40:00
XO|WD59|T1|RKO|53.383713|-155.799387|-4550.0|0.0|0.0|0.0|-S23|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-15T00:10:00|2019-09-05T23:50:00
XO|WD59|T2|RKO|53.383713|-155.799387|-4550.0|0.0|0.0|0.0|-S23Temperature|1.0|3.125E-4|celsius|8.3333E-4|2018-07-15T00:10:00|2019-09-05T23:50:00
XO|WD60||ACE|52.64488|-156.579823|-4518.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-14T00:00:00|2019-09-07T23:59:59
XO|WD60||HDH|52.64488|-156.579823|-4518.7|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-1007.75|0.4|Pa|100.0|2018-07-14T00:00:00|2019-09-07T23:59:59
XO|WD60||HH1|52.64488|-156.579823|-4518.7|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-14T00:00:00|2019-09-07T23:59:59
XO|WD60||HH2|52.64488|-156.579823|-4518.7|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-14T00:00:00|2019-09-07T23:59:59
XO|WD60||HHZ|52.64488|-156.579823|-4518.7|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-14T00:00:00|2019-09-07T23:59:59
XO|WD60||LCE|52.64488|-156.579823|-4518.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-07-14T00:00:00|2019-09-07T23:59:59
XO|WD60||LCL|52.64488|-156.579823|-4518.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|0.0166667|0.0|s|1.0|2018-07-14T00:00:00|2019-09-07T23:59:59
XO|WD60||LCQ|52.64488|-156.579823|-4518.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-07-14T00:00:00|2019-09-07T23:59:59
XO|WD60||LDH|52.64488|-156.579823|-4518.7|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-772.195|0.04|Pa|1.0|2018-07-14T00:00:00|2019-09-07T23:59:59
XO|WD60||LH1|52.64488|-156.579823|-4518.7|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-14T00:00:00|2019-09-07T23:59:59
XO|WD60||LH2|52.64488|-156.579823|-4518.7|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-14T00:00:00|2019-09-07T23:59:59
XO|WD60||LHZ|52.64488|-156.579823|-4518.7|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-14T00:00:00|2019-09-07T23:59:59
XO|WD60||LOG|52.64488|-156.579823|-4518.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-14T00:00:00|2019-09-07T23:59:59
XO|WD60||OAC|52.64488|-156.579823|-4518.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-14T00:00:00|2019-09-07T23:59:59
XO|WD60||OCF|52.64488|-156.579823|-4518.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-14T00:00:00|2019-09-07T23:59:59
XO|WD60||VCO|52.64488|-156.579823|-4518.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-14T00:00:00|2019-09-07T23:59:59
XO|WD60||VEA|52.64488|-156.579823|-4518.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-14T00:00:00|2019-09-07T23:59:59
XO|WD60||VEC|52.64488|-156.579823|-4518.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-14T00:00:00|2019-09-07T23:59:59
XO|WD60||VEP|52.64488|-156.579823|-4518.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-14T00:00:00|2019-09-07T23:59:59
XO|WD60||VFP|52.64488|-156.579823|-4518.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-14T00:00:00|2019-09-07T23:59:59
XO|WD60||VKI|52.64488|-156.579823|-4518.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-07-14T00:00:00|2019-09-07T23:59:59
XO|WD60||VM0|52.64488|-156.579823|-4518.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-14T00:00:00|2019-09-07T23:59:59
XO|WD60||VM1|52.64488|-156.579823|-4518.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-14T00:00:00|2019-09-07T23:59:59
XO|WD60||VM2|52.64488|-156.579823|-4518.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-14T00:00:00|2019-09-07T23:59:59
XO|WD60||VM3|52.64488|-156.579823|-4518.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-14T00:00:00|2019-09-07T23:59:59
XO|WD60||VM4|52.64488|-156.579823|-4518.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-14T00:00:00|2019-09-07T23:59:59
XO|WD60||VM5|52.64488|-156.579823|-4518.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-14T00:00:00|2019-09-07T23:59:59
XO|WD60||VM6|52.64488|-156.579823|-4518.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-14T00:00:00|2019-09-07T23:59:59
XO|WD60||VMU|52.64488|-156.579823|-4518.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-14T00:00:00|2019-09-07T23:59:59
XO|WD60||VMV|52.64488|-156.579823|-4518.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-14T00:00:00|2019-09-07T23:59:59
XO|WD60||VMW|52.64488|-156.579823|-4518.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-14T00:00:00|2019-09-07T23:59:59
XO|WD60||VMZ|52.64488|-156.579823|-4518.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-14T00:00:00|2019-09-07T23:59:59
XO|WD60||VPB|52.64488|-156.579823|-4518.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-14T00:00:00|2019-09-07T23:59:59
XO|WD60|AN|RKO|52.644867|-156.579823|-4519.0|0.0|0.0|0.0|-S37|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-16T00:20:00|2019-09-03T23:40:00
XO|WD60|T1|RKO|52.644867|-156.579823|-4519.0|0.0|0.0|0.0|-S37|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-16T00:10:00|2019-09-04T23:50:00
XO|WD60|T2|RKO|52.644867|-156.579823|-4519.0|0.0|0.0|0.0|-S37Temperature|1.0|3.125E-4|celsius|8.3333E-4|2018-07-16T00:10:00|2019-09-04T23:50:00
XO|WD61||ACE|54.647613|-156.868282|-2066.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-19T00:00:00|2019-09-01T23:59:59
XO|WD61||HDH|54.647613|-156.868282|-2066.7|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-1007.75|0.4|Pa|100.0|2018-07-19T00:00:00|2019-09-01T23:59:59
XO|WD61||HH1|54.647613|-156.868282|-2066.7|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-19T00:00:00|2019-09-01T23:59:59
XO|WD61||HH2|54.647613|-156.868282|-2066.7|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-19T00:00:00|2019-09-01T23:59:59
XO|WD61||HHZ|54.647613|-156.868282|-2066.7|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-19T00:00:00|2019-09-01T23:59:59
XO|WD61||LCE|54.647613|-156.868282|-2066.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-07-19T00:00:00|2019-09-01T23:59:59
XO|WD61||LCL|54.647613|-156.868282|-2066.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|0.0166667|0.0|s|1.0|2018-07-19T00:00:00|2019-09-01T23:59:59
XO|WD61||LCQ|54.647613|-156.868282|-2066.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-07-19T00:00:00|2019-09-01T23:59:59
XO|WD61||LDH|54.647613|-156.868282|-2066.7|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-772.195|0.04|Pa|1.0|2018-07-19T00:00:00|2019-09-01T23:59:59
XO|WD61||LH1|54.647613|-156.868282|-2066.7|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-19T00:00:00|2019-09-01T23:59:59
XO|WD61||LH2|54.647613|-156.868282|-2066.7|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-19T00:00:00|2019-09-01T23:59:59
XO|WD61||LHZ|54.647613|-156.868282|-2066.7|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-19T00:00:00|2019-09-01T23:59:59
XO|WD61||LOG|54.647613|-156.868282|-2066.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-19T00:00:00|2019-09-01T23:59:59
XO|WD61||OAC|54.647613|-156.868282|-2066.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-19T00:00:00|2019-09-01T23:59:59
XO|WD61||OCF|54.647613|-156.868282|-2066.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-19T00:00:00|2019-09-01T23:59:59
XO|WD61||VCO|54.647613|-156.868282|-2066.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-19T00:00:00|2019-09-01T23:59:59
XO|WD61||VEA|54.647613|-156.868282|-2066.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-19T00:00:00|2019-09-01T23:59:59
XO|WD61||VEC|54.647613|-156.868282|-2066.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-19T00:00:00|2019-09-01T23:59:59
XO|WD61||VEP|54.647613|-156.868282|-2066.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-19T00:00:00|2019-09-01T23:59:59
XO|WD61||VFP|54.647613|-156.868282|-2066.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-19T00:00:00|2019-09-01T23:59:59
XO|WD61||VKI|54.647613|-156.868282|-2066.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-07-19T00:00:00|2019-09-01T23:59:59
XO|WD61||VM0|54.647613|-156.868282|-2066.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-19T00:00:00|2019-09-01T23:59:59
XO|WD61||VM1|54.647613|-156.868282|-2066.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-19T00:00:00|2019-09-01T23:59:59
XO|WD61||VM2|54.647613|-156.868282|-2066.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-19T00:00:00|2019-09-01T23:59:59
XO|WD61||VM3|54.647613|-156.868282|-2066.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-19T00:00:00|2019-09-01T23:59:59
XO|WD61||VM4|54.647613|-156.868282|-2066.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-19T00:00:00|2019-09-01T23:59:59
XO|WD61||VM5|54.647613|-156.868282|-2066.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-19T00:00:00|2019-09-01T23:59:59
XO|WD61||VM6|54.647613|-156.868282|-2066.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-19T00:00:00|2019-09-01T23:59:59
XO|WD61||VMU|54.647613|-156.868282|-2066.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-19T00:00:00|2019-09-01T23:59:59
XO|WD61||VMV|54.647613|-156.868282|-2066.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-19T00:00:00|2019-09-01T23:59:59
XO|WD61||VMW|54.647613|-156.868282|-2066.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-19T00:00:00|2019-09-01T23:59:59
XO|WD61||VMZ|54.647613|-156.868282|-2066.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-19T00:00:00|2019-09-01T23:59:59
XO|WD61||VPB|54.647613|-156.868282|-2066.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-19T00:00:00|2019-09-01T23:59:59
XO|WD61|SO|RKO|54.647613|-156.579823|-2067.0|0.0|0.0|0.0|-S66|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-20T00:10:00|2019-08-28T23:50:00
XO|WD61|T1|RKO|54.647613|-156.579823|-2067.0|0.0|0.0|0.0|-S66|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-20T00:10:00|2019-08-28T23:50:00
XO|WD61|T2|RKO|54.647613|-156.579823|-2067.0|0.0|0.0|0.0|-S66|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-20T00:10:00|2019-08-28T23:50:00
XO|WD62||ACE|53.361962|-157.331882|-4625.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD62||HDH|53.361962|-157.331882|-4625.6|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-1007.75|0.4|Pa|100.0|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD62||HH1|53.361962|-157.331882|-4625.6|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD62||HH2|53.361962|-157.331882|-4625.6|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD62||HHZ|53.361962|-157.331882|-4625.6|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD62||LCE|53.361962|-157.331882|-4625.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD62||LCL|53.361962|-157.331882|-4625.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|0.0166667|0.0|s|1.0|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD62||LCQ|53.361962|-157.331882|-4625.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD62||LDH|53.361962|-157.331882|-4625.6|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-772.195|0.04|Pa|1.0|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD62||LH1|53.361962|-157.331882|-4625.6|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD62||LH2|53.361962|-157.331882|-4625.6|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD62||LHZ|53.361962|-157.331882|-4625.6|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD62||LOG|53.361962|-157.331882|-4625.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD62||OAC|53.361962|-157.331882|-4625.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD62||OCF|53.361962|-157.331882|-4625.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD62||VCO|53.361962|-157.331882|-4625.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD62||VEA|53.361962|-157.331882|-4625.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD62||VEC|53.361962|-157.331882|-4625.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD62||VEP|53.361962|-157.331882|-4625.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD62||VFP|53.361962|-157.331882|-4625.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD62||VKI|53.361962|-157.331882|-4625.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD62||VM0|53.361962|-157.331882|-4625.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD62||VM1|53.361962|-157.331882|-4625.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD62||VM2|53.361962|-157.331882|-4625.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD62||VM3|53.361962|-157.331882|-4625.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD62||VM4|53.361962|-157.331882|-4625.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD62||VM5|53.361962|-157.331882|-4625.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD62||VM6|53.361962|-157.331882|-4625.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD62||VMU|53.361962|-157.331882|-4625.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD62||VMV|53.361962|-157.331882|-4625.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD62||VMW|53.361962|-157.331882|-4625.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD62||VMZ|53.361962|-157.331882|-4625.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD62||VPB|53.361962|-157.331882|-4625.6|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD62|T1|RKO|53.361962|-157.331882|-4626.0|0.0|0.0|0.0|-S27|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-16T00:10:00|2019-09-04T23:50:00
XO|WD63||ACE|52.590072|-158.093575|-4656.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD63||HDH|52.590072|-158.093575|-4656.4|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-1007.75|0.4|Pa|100.0|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD63||HH1|52.590072|-158.093575|-4656.4|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD63||HH2|52.590072|-158.093575|-4656.4|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD63||HHZ|52.590072|-158.093575|-4656.4|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD63||LCE|52.590072|-158.093575|-4656.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD63||LCL|52.590072|-158.093575|-4656.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|0.0166667|0.0|s|1.0|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD63||LCQ|52.590072|-158.093575|-4656.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD63||LDH|52.590072|-158.093575|-4656.4|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-772.195|0.04|Pa|1.0|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD63||LH1|52.590072|-158.093575|-4656.4|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD63||LH2|52.590072|-158.093575|-4656.4|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD63||LHZ|52.590072|-158.093575|-4656.4|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD63||LOG|52.590072|-158.093575|-4656.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD63||OAC|52.590072|-158.093575|-4656.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD63||OCF|52.590072|-158.093575|-4656.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD63||VCO|52.590072|-158.093575|-4656.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD63||VEA|52.590072|-158.093575|-4656.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD63||VEC|52.590072|-158.093575|-4656.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD63||VEP|52.590072|-158.093575|-4656.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD63||VFP|52.590072|-158.093575|-4656.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD63||VKI|52.590072|-158.093575|-4656.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD63||VM0|52.590072|-158.093575|-4656.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD63||VM1|52.590072|-158.093575|-4656.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD63||VM2|52.590072|-158.093575|-4656.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD63||VM3|52.590072|-158.093575|-4656.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD63||VM4|52.590072|-158.093575|-4656.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD63||VM5|52.590072|-158.093575|-4656.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD63||VM6|52.590072|-158.093575|-4656.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD63||VMU|52.590072|-158.093575|-4656.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD63||VMV|52.590072|-158.093575|-4656.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD63||VMW|52.590072|-158.093575|-4656.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD63||VMZ|52.590072|-158.093575|-4656.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD63||VPB|52.590072|-158.093575|-4656.4|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-15T00:00:00|2019-09-08T23:59:59
XO|WD63|AN|RKO|52.590072|-158.093575|-4656.0|0.0|0.0|0.0|-S45|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-17T00:20:00|2019-09-04T23:40:00
XO|WD63|T1|RKO|52.590072|-158.093575|-4656.0|0.0|0.0|0.0|-S45|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-16T00:10:00|2019-09-03T23:50:00
XO|WD63|T2|RKO|52.590072|-158.093575|-4656.0|0.0|0.0|0.0|-S45Temperature|1.0|3.125E-4|celsius|8.3333E-4|2018-07-16T00:10:00|2019-09-03T23:50:00
XO|WD64||ACE|52.001077|-158.691562|-4753.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD64||HDH|52.001077|-158.691562|-4753.9|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-1007.75|0.4|Pa|100.0|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD64||HH1|52.001077|-158.691562|-4753.9|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD64||HH2|52.001077|-158.691562|-4753.9|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD64||HHZ|52.001077|-158.691562|-4753.9|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD64||LCE|52.001077|-158.691562|-4753.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD64||LCL|52.001077|-158.691562|-4753.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|0.0166667|0.0|s|1.0|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD64||LCQ|52.001077|-158.691562|-4753.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD64||LDH|52.001077|-158.691562|-4753.9|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-772.195|0.04|Pa|1.0|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD64||LH1|52.001077|-158.691562|-4753.9|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD64||LH2|52.001077|-158.691562|-4753.9|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD64||LHZ|52.001077|-158.691562|-4753.9|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD64||LOG|52.001077|-158.691562|-4753.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD64||OAC|52.001077|-158.691562|-4753.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD64||OCF|52.001077|-158.691562|-4753.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD64||VCO|52.001077|-158.691562|-4753.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD64||VEA|52.001077|-158.691562|-4753.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD64||VEC|52.001077|-158.691562|-4753.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD64||VEP|52.001077|-158.691562|-4753.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD64||VFP|52.001077|-158.691562|-4753.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD64||VKI|52.001077|-158.691562|-4753.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD64||VM0|52.001077|-158.691562|-4753.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD64||VM1|52.001077|-158.691562|-4753.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD64||VM2|52.001077|-158.691562|-4753.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD64||VM3|52.001077|-158.691562|-4753.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD64||VM4|52.001077|-158.691562|-4753.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD64||VM5|52.001077|-158.691562|-4753.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD64||VM6|52.001077|-158.691562|-4753.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD64||VMU|52.001077|-158.691562|-4753.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD64||VMV|52.001077|-158.691562|-4753.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD64||VMW|52.001077|-158.691562|-4753.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD64||VMZ|52.001077|-158.691562|-4753.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD64||VPB|52.001077|-158.691562|-4753.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD64|T1|RKO|52.001077|-158.691562|-4754.0|0.0|0.0|0.0|-S42|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-17T00:10:00|2019-09-03T23:50:00
XO|WD65||ACE|52.899057|-158.91238|-4718.2|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-16T00:00:00|2019-09-08T23:59:59
XO|WD65||HDH|52.899057|-158.91238|-4718.2|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-1007.75|0.4|Pa|100.0|2018-07-16T00:00:00|2019-09-08T23:59:59
XO|WD65||HH1|52.899057|-158.91238|-4718.2|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-16T00:00:00|2019-09-08T23:59:59
XO|WD65||HH2|52.899057|-158.91238|-4718.2|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-16T00:00:00|2019-09-08T23:59:59
XO|WD65||HHZ|52.899057|-158.91238|-4718.2|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-16T00:00:00|2019-09-08T23:59:59
XO|WD65||LCE|52.899057|-158.91238|-4718.2|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-07-16T00:00:00|2019-09-08T23:59:59
XO|WD65||LCL|52.899057|-158.91238|-4718.2|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|0.0166667|0.0|s|1.0|2018-07-16T00:00:00|2019-09-08T23:59:59
XO|WD65||LCQ|52.899057|-158.91238|-4718.2|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-07-16T00:00:00|2019-09-08T23:59:59
XO|WD65||LDH|52.899057|-158.91238|-4718.2|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-772.195|0.04|Pa|1.0|2018-07-16T00:00:00|2019-09-08T23:59:59
XO|WD65||LH1|52.899057|-158.91238|-4718.2|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-16T00:00:00|2019-09-08T23:59:59
XO|WD65||LH2|52.899057|-158.91238|-4718.2|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-16T00:00:00|2019-09-08T23:59:59
XO|WD65||LHZ|52.899057|-158.91238|-4718.2|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-16T00:00:00|2019-09-08T23:59:59
XO|WD65||LOG|52.899057|-158.91238|-4718.2|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-16T00:00:00|2019-09-08T23:59:59
XO|WD65||OAC|52.899057|-158.91238|-4718.2|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-16T00:00:00|2019-09-08T23:59:59
XO|WD65||OCF|52.899057|-158.91238|-4718.2|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-16T00:00:00|2019-09-08T23:59:59
XO|WD65||VCO|52.899057|-158.91238|-4718.2|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-16T00:00:00|2019-09-08T23:59:59
XO|WD65||VEA|52.899057|-158.91238|-4718.2|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-16T00:00:00|2019-09-08T23:59:59
XO|WD65||VEC|52.899057|-158.91238|-4718.2|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-16T00:00:00|2019-09-08T23:59:59
XO|WD65||VEP|52.899057|-158.91238|-4718.2|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-16T00:00:00|2019-09-08T23:59:59
XO|WD65||VFP|52.899057|-158.91238|-4718.2|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-16T00:00:00|2019-09-08T23:59:59
XO|WD65||VKI|52.899057|-158.91238|-4718.2|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-07-16T00:00:00|2019-09-08T23:59:59
XO|WD65||VM0|52.899057|-158.91238|-4718.2|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-16T00:00:00|2019-09-08T23:59:59
XO|WD65||VM1|52.899057|-158.91238|-4718.2|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-16T00:00:00|2019-09-08T23:59:59
XO|WD65||VM2|52.899057|-158.91238|-4718.2|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-16T00:00:00|2019-09-08T23:59:59
XO|WD65||VM3|52.899057|-158.91238|-4718.2|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-16T00:00:00|2019-09-08T23:59:59
XO|WD65||VM4|52.899057|-158.91238|-4718.2|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-16T00:00:00|2019-09-08T23:59:59
XO|WD65||VM5|52.899057|-158.91238|-4718.2|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-16T00:00:00|2019-09-08T23:59:59
XO|WD65||VM6|52.899057|-158.91238|-4718.2|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-16T00:00:00|2019-09-08T23:59:59
XO|WD65||VMU|52.899057|-158.91238|-4718.2|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-16T00:00:00|2019-09-08T23:59:59
XO|WD65||VMV|52.899057|-158.91238|-4718.2|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-16T00:00:00|2019-09-08T23:59:59
XO|WD65||VMW|52.899057|-158.91238|-4718.2|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-16T00:00:00|2019-09-08T23:59:59
XO|WD65||VMZ|52.899057|-158.91238|-4718.2|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-16T00:00:00|2019-09-08T23:59:59
XO|WD65||VPB|52.899057|-158.91238|-4718.2|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-16T00:00:00|2019-09-08T23:59:59
XO|WD65|T1|RKO|52.899057|-158.91238|-4718.0|0.0|0.0|0.0|-S67|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-17T00:10:00|2019-09-02T23:50:00
XO|WD65|T2|RKO|52.899057|-158.91238|-4718.0|0.0|0.0|0.0|-S67|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-17T00:10:00|2019-09-02T23:50:00
XO|WD66||ACE|53.31452|-159.617565|-4941.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD66||HDH|53.31452|-159.617565|-4941.1|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-1007.75|0.4|Pa|100.0|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD66||HH1|53.31452|-159.617565|-4941.1|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD66||HH2|53.31452|-159.617565|-4941.1|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD66||HHZ|53.31452|-159.617565|-4941.1|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD66||LCE|53.31452|-159.617565|-4941.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD66||LCL|53.31452|-159.617565|-4941.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|0.0166667|0.0|s|1.0|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD66||LCQ|53.31452|-159.617565|-4941.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD66||LDH|53.31452|-159.617565|-4941.1|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-772.195|0.04|Pa|1.0|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD66||LH1|53.31452|-159.617565|-4941.1|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD66||LH2|53.31452|-159.617565|-4941.1|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD66||LHZ|53.31452|-159.617565|-4941.1|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD66||LOG|53.31452|-159.617565|-4941.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD66||OAC|53.31452|-159.617565|-4941.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD66||OCF|53.31452|-159.617565|-4941.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD66||VCO|53.31452|-159.617565|-4941.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD66||VEA|53.31452|-159.617565|-4941.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD66||VEC|53.31452|-159.617565|-4941.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD66||VEP|53.31452|-159.617565|-4941.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD66||VFP|53.31452|-159.617565|-4941.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD66||VKI|53.31452|-159.617565|-4941.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD66||VM0|53.31452|-159.617565|-4941.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD66||VM1|53.31452|-159.617565|-4941.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD66||VM2|53.31452|-159.617565|-4941.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD66||VM3|53.31452|-159.617565|-4941.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD66||VM4|53.31452|-159.617565|-4941.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD66||VM5|53.31452|-159.617565|-4941.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD66||VM6|53.31452|-159.617565|-4941.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD66||VMU|53.31452|-159.617565|-4941.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD66||VMV|53.31452|-159.617565|-4941.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD66||VMW|53.31452|-159.617565|-4941.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD66||VMZ|53.31452|-159.617565|-4941.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD66||VPB|53.31452|-159.617565|-4941.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD66|T1|RKO|53.31452|-159.617565|-4941.0|0.0|0.0|0.0|-S72|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-18T00:10:00|2019-09-02T23:50:00
XO|WD66|T2|RKO|53.31452|-159.617565|-4941.0|0.0|0.0|0.0|-S72|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-18T00:10:00|2019-09-02T23:50:00
XO|WD67||ACE|52.162563|-160.035832|-4651.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD67||HDH|52.162563|-160.035832|-4651.5|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-1007.75|0.4|Pa|100.0|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD67||HH1|52.162563|-160.035832|-4651.5|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD67||HH2|52.162563|-160.035832|-4651.5|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD67||HHZ|52.162563|-160.035832|-4651.5|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD67||LCE|52.162563|-160.035832|-4651.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD67||LCL|52.162563|-160.035832|-4651.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|0.0166667|0.0|s|1.0|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD67||LCQ|52.162563|-160.035832|-4651.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD67||LDH|52.162563|-160.035832|-4651.5|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-772.195|0.04|Pa|1.0|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD67||LH1|52.162563|-160.035832|-4651.5|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD67||LH2|52.162563|-160.035832|-4651.5|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD67||LHZ|52.162563|-160.035832|-4651.5|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD67||LOG|52.162563|-160.035832|-4651.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD67||OAC|52.162563|-160.035832|-4651.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD67||OCF|52.162563|-160.035832|-4651.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD67||VCO|52.162563|-160.035832|-4651.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD67||VEA|52.162563|-160.035832|-4651.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD67||VEC|52.162563|-160.035832|-4651.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD67||VEP|52.162563|-160.035832|-4651.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD67||VFP|52.162563|-160.035832|-4651.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD67||VKI|52.162563|-160.035832|-4651.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD67||VM0|52.162563|-160.035832|-4651.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD67||VM1|52.162563|-160.035832|-4651.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD67||VM2|52.162563|-160.035832|-4651.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD67||VM3|52.162563|-160.035832|-4651.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD67||VM4|52.162563|-160.035832|-4651.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD67||VM5|52.162563|-160.035832|-4651.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD67||VM6|52.162563|-160.035832|-4651.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD67||VMU|52.162563|-160.035832|-4651.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD67||VMV|52.162563|-160.035832|-4651.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD67||VMW|52.162563|-160.035832|-4651.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD67||VMZ|52.162563|-160.035832|-4651.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD67||VPB|52.162563|-160.035832|-4651.5|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-16T00:00:00|2019-09-07T23:59:59
XO|WD67|AN|RKO|52.162563|-160.035832|-4652.0|0.0|0.0|0.0|-S68|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-23T00:20:00|2019-09-03T23:40:00
XO|WD68||ACE|52.917603|-160.081145|-4715.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD68||HDH|52.917603|-160.081145|-4715.1|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-1007.75|0.4|Pa|100.0|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD68||HH1|52.917603|-160.081145|-4715.1|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD68||HH2|52.917603|-160.081145|-4715.1|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD68||HHZ|52.917603|-160.081145|-4715.1|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD68||LCE|52.917603|-160.081145|-4715.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD68||LCL|52.917603|-160.081145|-4715.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|0.0166667|0.0|s|1.0|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD68||LCQ|52.917603|-160.081145|-4715.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD68||LDH|52.917603|-160.081145|-4715.1|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-772.195|0.04|Pa|1.0|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD68||LH1|52.917603|-160.081145|-4715.1|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD68||LH2|52.917603|-160.081145|-4715.1|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD68||LHZ|52.917603|-160.081145|-4715.1|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD68||LOG|52.917603|-160.081145|-4715.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD68||OAC|52.917603|-160.081145|-4715.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD68||OCF|52.917603|-160.081145|-4715.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD68||VCO|52.917603|-160.081145|-4715.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD68||VEA|52.917603|-160.081145|-4715.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD68||VEC|52.917603|-160.081145|-4715.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD68||VEP|52.917603|-160.081145|-4715.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD68||VFP|52.917603|-160.081145|-4715.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD68||VKI|52.917603|-160.081145|-4715.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD68||VM0|52.917603|-160.081145|-4715.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD68||VM1|52.917603|-160.081145|-4715.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD68||VM2|52.917603|-160.081145|-4715.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD68||VM3|52.917603|-160.081145|-4715.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD68||VM4|52.917603|-160.081145|-4715.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD68||VM5|52.917603|-160.081145|-4715.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD68||VM6|52.917603|-160.081145|-4715.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD68||VMU|52.917603|-160.081145|-4715.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD68||VMV|52.917603|-160.081145|-4715.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD68||VMW|52.917603|-160.081145|-4715.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD68||VMZ|52.917603|-160.081145|-4715.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD68||VPB|52.917603|-160.081145|-4715.1|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-17T00:00:00|2019-09-06T23:59:59
XO|WD68|T1|RKO|52.917603|-160.081145|-4715.0|0.0|0.0|0.0|-S46|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-18T00:10:00|2019-09-02T23:50:00
XO|WD68|T2|RKO|52.917603|-160.081145|-4715.0|0.0|0.0|0.0|-S46|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-18T00:10:00|2019-09-02T23:50:00
XO|WD69||ACE|53.782065|-160.34289|-3895.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-17T00:00:00|2019-09-03T23:59:59
XO|WD69||HDH|53.782065|-160.34289|-3895.9|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-1007.75|0.4|Pa|100.0|2018-07-17T00:00:00|2019-09-03T23:59:59
XO|WD69||HH1|53.782065|-160.34289|-3895.9|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-17T00:00:00|2019-09-03T23:59:59
XO|WD69||HH2|53.782065|-160.34289|-3895.9|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-17T00:00:00|2019-09-03T23:59:59
XO|WD69||HHZ|53.782065|-160.34289|-3895.9|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-17T00:00:00|2019-09-03T23:59:59
XO|WD69||LCE|53.782065|-160.34289|-3895.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-07-17T00:00:00|2019-09-03T23:59:59
XO|WD69||LCL|53.782065|-160.34289|-3895.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|0.0166667|0.0|s|1.0|2018-07-17T00:00:00|2019-09-03T23:59:59
XO|WD69||LCQ|53.782065|-160.34289|-3895.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-07-17T00:00:00|2019-09-03T23:59:59
XO|WD69||LDH|53.782065|-160.34289|-3895.9|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-772.195|0.04|Pa|1.0|2018-07-17T00:00:00|2019-09-03T23:59:59
XO|WD69||LH1|53.782065|-160.34289|-3895.9|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-17T00:00:00|2019-09-03T23:59:59
XO|WD69||LH2|53.782065|-160.34289|-3895.9|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-17T00:00:00|2019-09-03T23:59:59
XO|WD69||LHZ|53.782065|-160.34289|-3895.9|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-17T00:00:00|2019-09-03T23:59:59
XO|WD69||LOG|53.782065|-160.34289|-3895.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-17T00:00:00|2019-09-03T23:59:59
XO|WD69||OAC|53.782065|-160.34289|-3895.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-17T00:00:00|2019-09-03T23:59:59
XO|WD69||OCF|53.782065|-160.34289|-3895.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-17T00:00:00|2019-09-03T23:59:59
XO|WD69||VCO|53.782065|-160.34289|-3895.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-17T00:00:00|2019-09-03T23:59:59
XO|WD69||VEA|53.782065|-160.34289|-3895.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-17T00:00:00|2019-09-03T23:59:59
XO|WD69||VEC|53.782065|-160.34289|-3895.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-17T00:00:00|2019-09-03T23:59:59
XO|WD69||VEP|53.782065|-160.34289|-3895.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-17T00:00:00|2019-09-03T23:59:59
XO|WD69||VFP|53.782065|-160.34289|-3895.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-17T00:00:00|2019-09-03T23:59:59
XO|WD69||VKI|53.782065|-160.34289|-3895.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-07-17T00:00:00|2019-09-03T23:59:59
XO|WD69||VM0|53.782065|-160.34289|-3895.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-17T00:00:00|2019-09-03T23:59:59
XO|WD69||VM1|53.782065|-160.34289|-3895.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-17T00:00:00|2019-09-03T23:59:59
XO|WD69||VM2|53.782065|-160.34289|-3895.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-17T00:00:00|2019-09-03T23:59:59
XO|WD69||VM3|53.782065|-160.34289|-3895.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-17T00:00:00|2019-09-03T23:59:59
XO|WD69||VM4|53.782065|-160.34289|-3895.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-17T00:00:00|2019-09-03T23:59:59
XO|WD69||VM5|53.782065|-160.34289|-3895.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-17T00:00:00|2019-09-03T23:59:59
XO|WD69||VM6|53.782065|-160.34289|-3895.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-17T00:00:00|2019-09-03T23:59:59
XO|WD69||VMU|53.782065|-160.34289|-3895.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-17T00:00:00|2019-09-03T23:59:59
XO|WD69||VMV|53.782065|-160.34289|-3895.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-17T00:00:00|2019-09-03T23:59:59
XO|WD69||VMW|53.782065|-160.34289|-3895.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-17T00:00:00|2019-09-03T23:59:59
XO|WD69||VMZ|53.782065|-160.34289|-3895.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-17T00:00:00|2019-09-03T23:59:59
XO|WD69||VPB|53.782065|-160.34289|-3895.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-17T00:00:00|2019-09-03T23:59:59
XO|WD69|AN|RKO|53.782065|-160.34289|-3896.0|0.0|0.0|0.0|-S22|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-19T00:20:00|2019-08-29T23:40:00
XO|WD69|T1|RKO|53.782065|-160.34289|-3896.0|0.0|0.0|0.0|-S22|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-19T00:10:00|2019-08-29T23:50:00
XO|WD69|T2|RKO|53.782065|-160.34289|-3896.0|0.0|0.0|0.0|-S22Temperature|1.0|3.125E-4|celsius|8.3333E-4|2018-07-19T00:10:00|2019-08-29T23:50:00
XO|WD70||ACE|56.541073|-151.234407|-3252.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-22T00:00:00|2019-08-28T23:59:59
XO|WD70||HDH|56.541073|-151.234407|-3252.9|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-1007.75|0.4|Pa|100.0|2018-07-22T00:00:00|2019-08-28T23:59:59
XO|WD70||HH1|56.541073|-151.234407|-3252.9|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-22T00:00:00|2019-08-28T23:59:59
XO|WD70||HH2|56.541073|-151.234407|-3252.9|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-22T00:00:00|2019-08-28T23:59:59
XO|WD70||HHZ|56.541073|-151.234407|-3252.9|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-22T00:00:00|2019-08-28T23:59:59
XO|WD70||LCE|56.541073|-151.234407|-3252.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-07-22T00:00:00|2019-08-28T23:59:59
XO|WD70||LCL|56.541073|-151.234407|-3252.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|0.0166667|0.0|s|1.0|2018-07-22T00:00:00|2019-08-28T23:59:59
XO|WD70||LCQ|56.541073|-151.234407|-3252.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-07-22T00:00:00|2019-08-28T23:59:59
XO|WD70||LDH|56.541073|-151.234407|-3252.9|0.0|0.0|0.0|SIO Differential Pressure Gauge/Quanterra Q330 Lin|-772.195|0.04|Pa|1.0|2018-07-22T00:00:00|2019-08-28T23:59:59
XO|WD70||LH1|56.541073|-151.234407|-3252.9|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-22T00:00:00|2019-08-28T23:59:59
XO|WD70||LH2|56.541073|-151.234407|-3252.9|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-22T00:00:00|2019-08-28T23:59:59
XO|WD70||LHZ|56.541073|-151.234407|-3252.9|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-22T00:00:00|2019-08-28T23:59:59
XO|WD70||LOG|56.541073|-151.234407|-3252.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-22T00:00:00|2019-08-28T23:59:59
XO|WD70||OAC|56.541073|-151.234407|-3252.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-22T00:00:00|2019-08-28T23:59:59
XO|WD70||OCF|56.541073|-151.234407|-3252.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-22T00:00:00|2019-08-28T23:59:59
XO|WD70||VCO|56.541073|-151.234407|-3252.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-22T00:00:00|2019-08-28T23:59:59
XO|WD70||VEA|56.541073|-151.234407|-3252.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-22T00:00:00|2019-08-28T23:59:59
XO|WD70||VEC|56.541073|-151.234407|-3252.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-22T00:00:00|2019-08-28T23:59:59
XO|WD70||VEP|56.541073|-151.234407|-3252.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-22T00:00:00|2019-08-28T23:59:59
XO|WD70||VFP|56.541073|-151.234407|-3252.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-22T00:00:00|2019-08-28T23:59:59
XO|WD70||VKI|56.541073|-151.234407|-3252.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-07-22T00:00:00|2019-08-28T23:59:59
XO|WD70||VM0|56.541073|-151.234407|-3252.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-22T00:00:00|2019-08-28T23:59:59
XO|WD70||VM1|56.541073|-151.234407|-3252.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-22T00:00:00|2019-08-28T23:59:59
XO|WD70||VM2|56.541073|-151.234407|-3252.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-22T00:00:00|2019-08-28T23:59:59
XO|WD70||VM3|56.541073|-151.234407|-3252.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-22T00:00:00|2019-08-28T23:59:59
XO|WD70||VM4|56.541073|-151.234407|-3252.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-22T00:00:00|2019-08-28T23:59:59
XO|WD70||VM5|56.541073|-151.234407|-3252.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-22T00:00:00|2019-08-28T23:59:59
XO|WD70||VM6|56.541073|-151.234407|-3252.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-22T00:00:00|2019-08-28T23:59:59
XO|WD70||VMU|56.541073|-151.234407|-3252.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-22T00:00:00|2019-08-28T23:59:59
XO|WD70||VMV|56.541073|-151.234407|-3252.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-22T00:00:00|2019-08-28T23:59:59
XO|WD70||VMW|56.541073|-151.234407|-3252.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-22T00:00:00|2019-08-28T23:59:59
XO|WD70||VMZ|56.541073|-151.234407|-3252.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-22T00:00:00|2019-08-28T23:59:59
XO|WD70||VPB|56.541073|-151.234407|-3252.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-22T00:00:00|2019-08-28T23:59:59
XO|WD70|AN|RKO|56.541073|-151.234407|-3253.0|0.0|0.0|0.0|-S53|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-23T00:20:00|2019-08-25T23:40:00
XO|WD70|T1|RKO|56.541073|-151.234407|-3253.0|0.0|0.0|0.0|-S53|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-23T00:10:00|2019-08-25T23:50:00
XO|WD70|T2|RKO|56.541073|-151.234407|-3253.0|0.0|0.0|0.0|-S53Temperature|1.0|3.125E-4|celsius|8.3333E-4|2018-07-23T00:10:00|2019-08-25T23:50:00
XO|WD71|T1|RKO|56.15695|-153.078922|-1555.0|0.0|0.0|0.0|-S87|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-21T00:10:00|2019-08-26T23:50:00
XO|WD71|T2|RKO|56.15695|-153.078922|-1555.0|0.0|0.0|0.0|-S87|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-21T00:10:00|2019-08-26T23:50:00
XO|WD72|AN|RKO|56.257748|-151.81063|-4148.0|0.0|0.0|0.0|-S86|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-22T00:20:00|2019-08-25T23:40:00
XO|WD72|T1|RKO|56.257748|-151.81063|-4148.0|0.0|0.0|0.0|-S86|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-22T00:10:00|2019-08-25T23:50:00
XO|WD72|T2|RKO|56.257748|-151.81063|-4148.0|0.0|0.0|0.0|-S86Temperature|1.0|3.125E-4|celsius|8.3333E-4|2018-07-22T00:10:00|2019-08-25T23:50:00
XO|WD73|SO|RKO|54.419958|-158.513277|-2133.0|0.0|0.0|0.0|-S80|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-20T00:10:00|2019-08-28T23:50:00
XO|WD73|T1|RKO|54.419958|-158.513277|-2133.0|0.0|0.0|0.0|-S80|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-19T00:10:00|2019-08-28T23:50:00
XO|WD73|T2|RKO|54.419958|-158.513277|-2133.0|0.0|0.0|0.0|-S80Temperature|1.0|3.125E-4|celsius|8.3333E-4|2018-07-19T00:10:00|2019-08-28T23:50:00
XO|WD74|SO|RKO|54.369193|-159.361628|-903.0|0.0|0.0|0.0|-S85|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-19T00:10:00|2019-08-29T23:50:00
XO|WD74|T1|RKO|54.369193|-159.361628|-903.0|0.0|0.0|0.0|-S85|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-19T00:10:00|2019-08-28T23:50:00
XO|WD74|T2|RKO|54.369193|-159.361628|-903.0|0.0|0.0|0.0|-S85Temperature|1.0|3.125E-4|celsius|8.3333E-4|2018-07-19T00:10:00|2019-08-28T23:50:00
XO|WD75|SO|RKO|54.17963|-160.256908|-1109.0|0.0|0.0|0.0|-S84|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-19T00:10:00|2019-08-29T23:50:00
XO|WD75|T1|RKO|54.17963|-160.256908|-1109.0|0.0|0.0|0.0|-S84|1.0|3.125E-4|CELSIUS|8.333333333333334E-4|2018-07-19T00:10:00|2019-08-29T23:50:00
XO|WD75|T2|RKO|54.17963|-160.256908|-1109.0|0.0|0.0|0.0|-S84Temperature|1.0|3.125E-4|celsius|8.3333E-4|2018-07-19T00:10:00|2019-08-29T23:50:00
XO|WP24||ACE|56.9241|-158.6603|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WP24||HHE|56.9241|-158.6603|43.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WP24||HHN|56.9241|-158.6603|43.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WP24||HHZ|56.9241|-158.6603|43.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WP24||LCE|56.9241|-158.6603|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WP24||LCQ|56.9241|-158.6603|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WP24||LHE|56.9241|-158.6603|43.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WP24||LHN|56.9241|-158.6603|43.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WP24||LHZ|56.9241|-158.6603|43.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WP24||LOG|56.9241|-158.6603|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WP24||OCF|56.9241|-158.6603|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WP24||VCO|56.9241|-158.6603|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WP24||VEA|56.9241|-158.6603|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WP24||VEC|56.9241|-158.6603|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WP24||VEP|56.9241|-158.6603|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WP24||VKI|56.9241|-158.6603|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WP24||VM1|56.9241|-158.6603|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WP24||VM2|56.9241|-158.6603|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WP24||VM3|56.9241|-158.6603|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WP24||VPB|56.9241|-158.6603|43.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WP25||ACE|56.453|-159.7563|47.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP25||HHE|56.453|-159.7563|47.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP25||HHN|56.453|-159.7563|47.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP25||HHZ|56.453|-159.7563|47.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP25||LCE|56.453|-159.7563|47.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP25||LCQ|56.453|-159.7563|47.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP25||LHE|56.453|-159.7563|47.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP25||LHN|56.453|-159.7563|47.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP25||LHZ|56.453|-159.7563|47.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP25||LOG|56.453|-159.7563|47.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP25||OCF|56.453|-159.7563|47.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP25||VCO|56.453|-159.7563|47.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP25||VEA|56.453|-159.7563|47.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP25||VEC|56.453|-159.7563|47.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP25||VEP|56.453|-159.7563|47.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP25||VKI|56.453|-159.7563|47.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP25||VM1|56.453|-159.7563|47.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP25||VM2|56.453|-159.7563|47.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP25||VM3|56.453|-159.7563|47.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP25||VPB|56.453|-159.7563|47.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP30||ACE|56.001|-161.2014|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP30||HHE|56.001|-161.2014|41.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP30||HHN|56.001|-161.2014|41.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP30||HHZ|56.001|-161.2014|41.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP30||LCE|56.001|-161.2014|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP30||LCQ|56.001|-161.2014|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP30||LHE|56.001|-161.2014|41.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP30||LHN|56.001|-161.2014|41.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP30||LHZ|56.001|-161.2014|41.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP30||LOG|56.001|-161.2014|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP30||OCF|56.001|-161.2014|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP30||VCO|56.001|-161.2014|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP30||VEA|56.001|-161.2014|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP30||VEC|56.001|-161.2014|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP30||VEP|56.001|-161.2014|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP30||VKI|56.001|-161.2014|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP30||VM1|56.001|-161.2014|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP30||VM2|56.001|-161.2014|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP30||VM3|56.001|-161.2014|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WP30||VPB|56.001|-161.2014|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-05-29T12:00:00|2019-12-31T23:59:59
XO|WS26||ACE|55.9123|-159.1431|36.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WS26||HHE|55.9123|-159.1431|36.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WS26||HHN|55.9123|-159.1431|36.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WS26||HHZ|55.9123|-159.1431|36.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WS26||HNE|55.9123|-159.1431|36.0|0.0|90.0|0.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.02|m/s**2|100.0|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WS26||HNN|55.9123|-159.1431|36.0|0.0|0.0|0.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.02|m/s**2|100.0|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WS26||HNZ|55.9123|-159.1431|36.0|0.0|0.0|-90.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.02|m/s**2|100.0|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WS26||LCE|55.9123|-159.1431|36.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WS26||LCQ|55.9123|-159.1431|36.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WS26||LHE|55.9123|-159.1431|36.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WS26||LHN|55.9123|-159.1431|36.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WS26||LHZ|55.9123|-159.1431|36.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WS26||LNE|55.9123|-159.1431|36.0|0.0|90.0|0.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.002|m/s**2|1.0|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WS26||LNN|55.9123|-159.1431|36.0|0.0|0.0|0.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.002|m/s**2|1.0|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WS26||LNZ|55.9123|-159.1431|36.0|0.0|0.0|-90.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.002|m/s**2|1.0|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WS26||LOG|55.9123|-159.1431|36.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WS26||OCF|55.9123|-159.1431|36.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WS26||VCO|55.9123|-159.1431|36.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WS26||VEA|55.9123|-159.1431|36.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WS26||VEC|55.9123|-159.1431|36.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WS26||VEP|55.9123|-159.1431|36.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WS26||VKI|55.9123|-159.1431|36.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WS26||VM1|55.9123|-159.1431|36.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WS26||VM2|55.9123|-159.1431|36.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WS26||VM3|55.9123|-159.1431|36.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WS26||VPB|55.9123|-159.1431|36.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-05-28T12:00:00|2019-12-31T23:59:59
XO|WS27||ACE|55.2236|-159.9136|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-24T00:00:00|2019-12-31T23:59:59
XO|WS27||HHE|55.2236|-159.9136|41.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-24T00:00:00|2019-12-31T23:59:59
XO|WS27||HHN|55.2236|-159.9136|41.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-24T00:00:00|2019-12-31T23:59:59
XO|WS27||HHZ|55.2236|-159.9136|41.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-24T00:00:00|2019-12-31T23:59:59
XO|WS27||HNE|55.2236|-159.9136|41.0|0.0|90.0|0.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.02|m/s**2|100.0|2018-05-24T00:00:00|2019-12-31T23:59:59
XO|WS27||HNN|55.2236|-159.9136|41.0|0.0|0.0|0.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.02|m/s**2|100.0|2018-05-24T00:00:00|2019-12-31T23:59:59
XO|WS27||HNZ|55.2236|-159.9136|41.0|0.0|0.0|-90.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.02|m/s**2|100.0|2018-05-24T00:00:00|2019-12-31T23:59:59
XO|WS27||LCE|55.2236|-159.9136|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-05-24T00:00:00|2019-12-31T23:59:59
XO|WS27||LCQ|55.2236|-159.9136|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-05-24T00:00:00|2019-12-31T23:59:59
XO|WS27||LHE|55.2236|-159.9136|41.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-24T00:00:00|2019-12-31T23:59:59
XO|WS27||LHN|55.2236|-159.9136|41.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-24T00:00:00|2019-12-31T23:59:59
XO|WS27||LHZ|55.2236|-159.9136|41.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-24T00:00:00|2019-12-31T23:59:59
XO|WS27||LNE|55.2236|-159.9136|41.0|0.0|90.0|0.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.002|m/s**2|1.0|2018-05-24T00:00:00|2019-12-31T23:59:59
XO|WS27||LNN|55.2236|-159.9136|41.0|0.0|0.0|0.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.002|m/s**2|1.0|2018-05-24T00:00:00|2019-12-31T23:59:59
XO|WS27||LNZ|55.2236|-159.9136|41.0|0.0|0.0|-90.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.002|m/s**2|1.0|2018-05-24T00:00:00|2019-12-31T23:59:59
XO|WS27||LOG|55.2236|-159.9136|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-24T00:00:00|2019-12-31T23:59:59
XO|WS27||OCF|55.2236|-159.9136|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-24T00:00:00|2019-12-31T23:59:59
XO|WS27||VCO|55.2236|-159.9136|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-24T00:00:00|2019-12-31T23:59:59
XO|WS27||VEA|55.2236|-159.9136|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-24T00:00:00|2019-12-31T23:59:59
XO|WS27||VEC|55.2236|-159.9136|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-24T00:00:00|2019-12-31T23:59:59
XO|WS27||VEP|55.2236|-159.9136|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-24T00:00:00|2019-12-31T23:59:59
XO|WS27||VKI|55.2236|-159.9136|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-05-24T00:00:00|2019-12-31T23:59:59
XO|WS27||VM1|55.2236|-159.9136|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-24T00:00:00|2019-12-31T23:59:59
XO|WS27||VM2|55.2236|-159.9136|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-24T00:00:00|2019-12-31T23:59:59
XO|WS27||VM3|55.2236|-159.9136|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-24T00:00:00|2019-12-31T23:59:59
XO|WS27||VPB|55.2236|-159.9136|41.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-05-24T00:00:00|2019-12-31T23:59:59
XO|WS28||ACE|55.0746|-162.2992|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-31T00:00:00|2019-12-31T23:59:59
XO|WS28||HHE|55.0746|-162.2992|45.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-31T00:00:00|2019-12-31T23:59:59
XO|WS28||HHN|55.0746|-162.2992|45.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-31T00:00:00|2019-12-31T23:59:59
XO|WS28||HHZ|55.0746|-162.2992|45.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.03939E8|0.4|m/s|100.0|2018-05-31T00:00:00|2019-12-31T23:59:59
XO|WS28||HNE|55.0746|-162.2992|45.0|0.0|90.0|0.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.02|m/s**2|100.0|2018-05-31T00:00:00|2019-12-31T23:59:59
XO|WS28||HNN|55.0746|-162.2992|45.0|0.0|0.0|0.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.02|m/s**2|100.0|2018-05-31T00:00:00|2019-12-31T23:59:59
XO|WS28||HNZ|55.0746|-162.2992|45.0|0.0|0.0|-90.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.02|m/s**2|100.0|2018-05-31T00:00:00|2019-12-31T23:59:59
XO|WS28||LCE|55.0746|-162.2992|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-05-31T00:00:00|2019-12-31T23:59:59
XO|WS28||LCQ|55.0746|-162.2992|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-05-31T00:00:00|2019-12-31T23:59:59
XO|WS28||LHE|55.0746|-162.2992|45.0|0.0|90.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-31T00:00:00|2019-12-31T23:59:59
XO|WS28||LHN|55.0746|-162.2992|45.0|0.0|0.0|0.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-31T00:00:00|2019-12-31T23:59:59
XO|WS28||LHZ|55.0746|-162.2992|45.0|0.0|0.0|-90.0|Nanometrics Trillium 120 Sec PH Response/Quanterra|5.02851E8|0.03|m/s|1.0|2018-05-31T00:00:00|2019-12-31T23:59:59
XO|WS28||LNE|55.0746|-162.2992|45.0|0.0|90.0|0.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.002|m/s**2|1.0|2018-05-31T00:00:00|2019-12-31T23:59:59
XO|WS28||LNN|55.0746|-162.2992|45.0|0.0|0.0|0.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.002|m/s**2|1.0|2018-05-31T00:00:00|2019-12-31T23:59:59
XO|WS28||LNZ|55.0746|-162.2992|45.0|0.0|0.0|-90.0|Nanometrics Titan 2g/Quanterra 330 Linear Phase Co|427536.0|0.002|m/s**2|1.0|2018-05-31T00:00:00|2019-12-31T23:59:59
XO|WS28||LOG|55.0746|-162.2992|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-31T00:00:00|2019-12-31T23:59:59
XO|WS28||OCF|55.0746|-162.2992|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite||||0.0|2018-05-31T00:00:00|2019-12-31T23:59:59
XO|WS28||VCO|55.0746|-162.2992|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-31T00:00:00|2019-12-31T23:59:59
XO|WS28||VEA|55.0746|-162.2992|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-31T00:00:00|2019-12-31T23:59:59
XO|WS28||VEC|55.0746|-162.2992|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-05-31T00:00:00|2019-12-31T23:59:59
XO|WS28||VEP|55.0746|-162.2992|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-05-31T00:00:00|2019-12-31T23:59:59
XO|WS28||VKI|55.0746|-162.2992|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-05-31T00:00:00|2019-12-31T23:59:59
XO|WS28||VM1|55.0746|-162.2992|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-31T00:00:00|2019-12-31T23:59:59
XO|WS28||VM2|55.0746|-162.2992|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-31T00:00:00|2019-12-31T23:59:59
XO|WS28||VM3|55.0746|-162.2992|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|V|0.1|2018-05-31T00:00:00|2019-12-31T23:59:59
XO|WS28||VPB|55.0746|-162.2992|45.0|0.0|0.0|0.0|Quanterra 330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-05-31T00:00:00|2019-12-31T23:59:59
XO|WS71||ACE|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||BDH|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|SIO Differential Pressure Gauge/QEP - Q330 Environ|-8062.03|0.4|Pa|40.0|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||HH1|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||HH2|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||HHZ|56.15695|-153.078922|-1554.8|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||HN1|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea|427993.0|0.02|m/s**2|100.0|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||HN2|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea|427993.0|0.02|m/s**2|100.0|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||HNZ|56.15695|-153.078922|-1554.8|0.0|0.0|-90.0|Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea|427993.0|0.02|m/s**2|100.0|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||LCE|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||LCL|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|0.0166667|0.0|s|1.0|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||LCQ|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||LDH|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|SIO Differential Pressure Gauge/QEP - Q330 Environ|-8062.03|0.4|Pa|1.0|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||LDI|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|QEP - Q330 Environmental Processor|10.0|0.0|Pa|1.0|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||LEE|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|QEP - Q330 Environmental Processor|1000000.0|0.0|SEC|1.0|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||LEO|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|QEP - Q330 Environmental Processor|1.0|0.0|V|1.0|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||LEP|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|QEP - Q330 Environmental Processor|10.0|0.0|V|1.0|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||LH1|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||LH2|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||LHZ|56.15695|-153.078922|-1554.8|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||LII|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|QEP - Q330 Environmental Processor|1.0|0.0|percent|1.0|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||LKI|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|QEP - Q330 Environmental Processor|10.0|0.0|C|1.0|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||LN1|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea|427993.0|0.002|m/s**2|1.0|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||LN2|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea|427993.0|0.002|m/s**2|1.0|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||LNZ|56.15695|-153.078922|-1554.8|0.0|0.0|-90.0|Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea|427993.0|0.002|m/s**2|1.0|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||LOG|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||OAC|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||OCF|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||VCO|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||VEA|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||VEC|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||VEP|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||VFP|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||VKI|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||VM0|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||VM1|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||VM2|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||VM3|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||VM4|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||VM5|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||VM6|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||VMU|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||VMV|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||VMW|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||VMZ|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS71||VPB|56.15695|-153.078922|-1554.8|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-20T00:00:00|2019-09-03T23:59:59
XO|WS72||ACE|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||BDH|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|SIO Differential Pressure Gauge/QEP - Q330 Environ|-8062.03|0.4|Pa|40.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||HH1|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||HH2|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||HHZ|56.257748|-151.81063|-4141.7|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||HN1|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea|427993.0|0.02|m/s**2|100.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||HN2|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea|427993.0|0.02|m/s**2|100.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||HNZ|56.257748|-151.81063|-4141.7|0.0|0.0|-90.0|Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea|427993.0|0.02|m/s**2|100.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||LCE|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||LCL|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|0.0166667|0.0|s|1.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||LCQ|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||LDH|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|SIO Differential Pressure Gauge/QEP - Q330 Environ|-8062.03|0.4|Pa|1.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||LDI|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|QEP - Q330 Environmental Processor|10.0|0.0|Pa|1.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||LEE|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|QEP - Q330 Environmental Processor|1000000.0|0.0|SEC|1.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||LEO|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|QEP - Q330 Environmental Processor|1.0|0.0|V|1.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||LEP|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|QEP - Q330 Environmental Processor|10.0|0.0|V|1.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||LH1|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||LH2|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||LHZ|56.257748|-151.81063|-4141.7|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||LII|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|QEP - Q330 Environmental Processor|1.0|0.0|percent|1.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||LKI|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|QEP - Q330 Environmental Processor|10.0|0.0|C|1.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||LN1|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea|427993.0|0.002|m/s**2|1.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||LN2|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea|427993.0|0.002|m/s**2|1.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||LNZ|56.257748|-151.81063|-4141.7|0.0|0.0|-90.0|Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea|427993.0|0.002|m/s**2|1.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||LOG|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||OAC|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||OCF|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||VCO|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||VEA|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||VEC|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||VEP|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||VFP|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||VKI|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||VM0|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||VM1|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||VM2|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||VM3|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||VM4|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||VM5|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||VM6|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||VMU|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||VMV|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||VMW|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||VMZ|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS72||VPB|56.257748|-151.81063|-4141.7|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-21T00:00:00|2019-08-29T23:59:59
XO|WS73||ACE|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||BDH|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|SIO Differential Pressure Gauge/QEP - Q330 Environ|-8062.03|0.4|Pa|40.0|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||HH1|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||HH2|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||HHZ|54.419958|-158.513277|-2132.9|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||HN1|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea|427993.0|0.02|m/s**2|100.0|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||HN2|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea|427993.0|0.02|m/s**2|100.0|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||HNZ|54.419958|-158.513277|-2132.9|0.0|0.0|-90.0|Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea|427993.0|0.02|m/s**2|100.0|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||LCE|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||LCL|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|0.0166667|0.0|s|1.0|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||LCQ|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||LDH|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|SIO Differential Pressure Gauge/QEP - Q330 Environ|-8062.03|0.4|Pa|1.0|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||LDI|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|QEP - Q330 Environmental Processor|10.0|0.0|Pa|1.0|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||LEE|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|QEP - Q330 Environmental Processor|1000000.0|0.0|SEC|1.0|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||LEO|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|QEP - Q330 Environmental Processor|1.0|0.0|V|1.0|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||LEP|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|QEP - Q330 Environmental Processor|10.0|0.0|V|1.0|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||LH1|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||LH2|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||LHZ|54.419958|-158.513277|-2132.9|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||LII|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|QEP - Q330 Environmental Processor|1.0|0.0|percent|1.0|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||LKI|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|QEP - Q330 Environmental Processor|10.0|0.0|C|1.0|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||LN1|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea|427993.0|0.002|m/s**2|1.0|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||LN2|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea|427993.0|0.002|m/s**2|1.0|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||LNZ|54.419958|-158.513277|-2132.9|0.0|0.0|-90.0|Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea|427993.0|0.002|m/s**2|1.0|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||LOG|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||OAC|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||OCF|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||VCO|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||VEA|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||VEC|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||VEP|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||VFP|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||VKI|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||VM0|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||VM1|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||VM2|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||VM3|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||VM4|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||VM5|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||VM6|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||VMU|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||VMV|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||VMW|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||VMZ|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS73||VPB|54.419958|-158.513277|-2132.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-18T00:00:00|2019-10-22T23:59:59
XO|WS74||ACE|54.369193|-159.361628|-902.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||BDH|54.369193|-159.361628|-902.9|0.0|0.0|0.0|SIO Differential Pressure Gauge/QEP - Q330 Environ|-8062.03|0.4|Pa|40.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||HH1|54.369193|-159.361628|-902.9|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||HH2|54.369193|-159.361628|-902.9|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||HHZ|54.369193|-159.361628|-902.9|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||HN1|54.369193|-159.361628|-902.9|0.0|0.0|0.0|Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea|427993.0|0.02|m/s**2|100.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||HN2|54.369193|-159.361628|-902.9|0.0|0.0|0.0|Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea|427993.0|0.02|m/s**2|100.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||HNZ|54.369193|-159.361628|-902.9|0.0|0.0|-90.0|Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea|427993.0|0.02|m/s**2|100.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||LCE|54.369193|-159.361628|-902.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||LCL|54.369193|-159.361628|-902.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|0.0166667|0.0|s|1.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||LCQ|54.369193|-159.361628|-902.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||LDH|54.369193|-159.361628|-902.9|0.0|0.0|0.0|SIO Differential Pressure Gauge/QEP - Q330 Environ|-8062.03|0.4|Pa|1.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||LDI|54.369193|-159.361628|-902.9|0.0|0.0|0.0|QEP - Q330 Environmental Processor|10.0|0.0|Pa|1.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||LEE|54.369193|-159.361628|-902.9|0.0|0.0|0.0|QEP - Q330 Environmental Processor|1000000.0|0.0|SEC|1.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||LEO|54.369193|-159.361628|-902.9|0.0|0.0|0.0|QEP - Q330 Environmental Processor|1.0|0.0|V|1.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||LEP|54.369193|-159.361628|-902.9|0.0|0.0|0.0|QEP - Q330 Environmental Processor|10.0|0.0|V|1.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||LH1|54.369193|-159.361628|-902.9|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||LH2|54.369193|-159.361628|-902.9|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||LHZ|54.369193|-159.361628|-902.9|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||LII|54.369193|-159.361628|-902.9|0.0|0.0|0.0|QEP - Q330 Environmental Processor|1.0|0.0|percent|1.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||LKI|54.369193|-159.361628|-902.9|0.0|0.0|0.0|QEP - Q330 Environmental Processor|10.0|0.0|C|1.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||LN1|54.369193|-159.361628|-902.9|0.0|0.0|0.0|Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea|427993.0|0.002|m/s**2|1.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||LN2|54.369193|-159.361628|-902.9|0.0|0.0|0.0|Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea|427993.0|0.002|m/s**2|1.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||LNZ|54.369193|-159.361628|-902.9|0.0|0.0|-90.0|Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea|427993.0|0.002|m/s**2|1.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||LOG|54.369193|-159.361628|-902.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||OAC|54.369193|-159.361628|-902.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||OCF|54.369193|-159.361628|-902.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||VCO|54.369193|-159.361628|-902.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||VEA|54.369193|-159.361628|-902.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||VEC|54.369193|-159.361628|-902.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||VEP|54.369193|-159.361628|-902.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||VFP|54.369193|-159.361628|-902.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||VKI|54.369193|-159.361628|-902.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||VM0|54.369193|-159.361628|-902.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||VM1|54.369193|-159.361628|-902.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||VM2|54.369193|-159.361628|-902.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||VM3|54.369193|-159.361628|-902.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||VM4|54.369193|-159.361628|-902.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||VM5|54.369193|-159.361628|-902.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||VM6|54.369193|-159.361628|-902.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||VMU|54.369193|-159.361628|-902.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||VMV|54.369193|-159.361628|-902.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||VMW|54.369193|-159.361628|-902.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||VMZ|54.369193|-159.361628|-902.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS74||VPB|54.369193|-159.361628|-902.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||ACE|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||BDH|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|SIO Differential Pressure Gauge/QEP - Q330 Environ|-8062.03|0.4|Pa|40.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||HH1|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||HH2|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||HHZ|54.17963|-160.256908|-1108.9|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.29138E8|0.3|m/s|100.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||HN1|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea|427993.0|0.02|m/s**2|100.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||HN2|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea|427993.0|0.02|m/s**2|100.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||HNZ|54.17963|-160.256908|-1108.9|0.0|0.0|-90.0|Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea|427993.0|0.02|m/s**2|100.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||LCE|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000000.0|0.0|s|1.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||LCL|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|0.0166667|0.0|s|1.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||LCQ|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|percent|1.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||LDH|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|SIO Differential Pressure Gauge/QEP - Q330 Environ|-8062.03|0.4|Pa|1.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||LDI|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|QEP - Q330 Environmental Processor|10.0|0.0|Pa|1.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||LEE|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|QEP - Q330 Environmental Processor|1000000.0|0.0|SEC|1.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||LEO|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|QEP - Q330 Environmental Processor|1.0|0.0|V|1.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||LEP|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|QEP - Q330 Environmental Processor|10.0|0.0|V|1.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||LH1|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||LH2|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||LHZ|54.17963|-160.256908|-1108.9|0.0|0.0|-90.0|Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line|6.27283E8|0.03|m/s|1.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||LII|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|QEP - Q330 Environmental Processor|1.0|0.0|percent|1.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||LKI|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|QEP - Q330 Environmental Processor|10.0|0.0|C|1.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||LN1|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea|427993.0|0.002|m/s**2|1.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||LN2|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea|427993.0|0.002|m/s**2|1.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||LNZ|54.17963|-160.256908|-1108.9|0.0|0.0|-90.0|Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea|427993.0|0.002|m/s**2|1.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||LOG|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||OAC|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||OCF|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite||||0.0|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||VCO|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||VEA|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||VEC|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1000.0|0.0|A|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||VEP|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|6.66667|0.0|V|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||VFP|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||VKI|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|1.0|0.0|celsius|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||VM0|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||VM1|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||VM2|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||VM3|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||VM4|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||VM5|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||VM6|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||VMU|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||VMV|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||VMW|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||VMZ|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|V|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59
XO|WS75||VPB|54.17963|-160.256908|-1108.9|0.0|0.0|0.0|Quanterra Q330 Linear Phase Composite|10.0|0.0|percent|0.1|2018-07-18T00:00:00|2019-09-04T23:59:59